The dosimetric effect of residual breath-hold motion in pencil beam scanned proton therapy - An experimental study

被引:7
|
作者
Gorgisyan, Jenny [1 ,2 ,3 ,7 ]
Lomax, Antony J. [1 ,4 ]
af Rosenschold, Per Munck [3 ,5 ]
Persson, Gitte F. [2 ,8 ,9 ]
Krieger, Miriam [1 ,4 ]
Colvill, Emma [1 ]
Scherman, Jonas [5 ]
Gagnon-Moisan, Francis [1 ]
Egloff, Martina [1 ]
Fattori, Giovanni [1 ]
Engelholm, Svend Aage [2 ]
Weber, Damien C. [1 ,6 ]
Perrin, Rosalind [1 ,10 ]
机构
[1] ETH Domain, Paul Scherrer Inst, Zurich, Switzerland
[2] Copenhagen Univ Hosp, Rigshosp, Dept Oncol, Copenhagen, Denmark
[3] Univ Copenhagen, Niels Bohr Inst, Herlev, Denmark
[4] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
[5] Skane Univ Hosp, Dept Hematol Oncol & Radiat Phys, Radiat Phys, Lund, Sweden
[6] Univ Hosp Zurich, Radiat Oncol Dept, Zurich, Switzerland
[7] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[8] Univ Copenhagen, Herlev Hosp, Dept Oncol, Herlev, Denmark
[9] Univ Copenhagen, Dept Clin Med, Fac Med Sci, Herlev, Denmark
[10] Univ Klinikum Erlangen, Dept Med Radiat Phys, Strahlenklin, Univ Str 29, D-91054 Erlangen, Germany
关键词
4D phantom; PBS proton therapy; Breath-hold; Lung tumours; LUNG-TUMORS; RESPIRATORY MOTION; RADIOTHERAPY; UNCERTAINTIES; MITIGATION; PHANTOM; CANCER; ROBUSTNESS; TARGETS; THORAX;
D O I
10.1016/j.radonc.2019.01.033
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Motion management in the treatment of lung cancer is necessary to assure highest quality of the delivered radiation therapy. In this study, the breath-hold technique is experimentally investigated for pencil beam scanned (PBS) proton therapy, with respect to the dosimetric effect of residual breath-hold motion. Material and methods: Three-dimensional (3D)-printed tumours extracted from CT scans of three patients were inserted into a dynamic anthropomorphic breathing phantom. The target was set up to move with the individual patient's tumour motion during breath-hold as previously assessed on fluoroscopy. Target dose was measured with radio-chromic film, and both single field uniform dose (SFUD) and intensity-modulated proton therapy (IMPT) plans were delivered. Experiments were repeated for each patient without any motion, to compute the relative dose deviation between static and breath-hold cases. Results: SFUD plans showed small dose deviations between static and breath-hold cases, as evidenced by the gamma pass rate (3%, 3 mm) of 85% or higher. Dose deviation was more evident for IMPT plans, with gamma pass rate reduced to 50-70%. Conclusions: The breath-hold technique is robust to residual intra-breath-hold motion for SFUD treatment plans, based on our experimental study. IMPT was less robust with larger detected dose deviations. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 50 条
  • [21] The impact of motion on onboard MRI-guided pencil beam scanned proton therapy treatments
    Duetschler, Alisha
    Safai, Sairos
    Weber, Damien C.
    Lomax, Antony J.
    Zhang, Ye
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4219 - S4222
  • [22] Dosimetric impact of breath-hold in the treatment of hepatocellular carcinoma by conformal radiation therapy
    Kubas, A.
    Chapet, O.
    Merle, P.
    Lorchel, F.
    d'Hombres, A.
    Mornex, F.
    CANCER RADIOTHERAPIE, 2009, 13 (01): : 24 - 29
  • [23] Dosimetric consequences of tumour motion due to respiration for a scanned proton beam
    Kraus, K. M.
    Heath, E.
    Oelfke, U.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (20): : 6563 - 6581
  • [24] Dosimetric uncertainties in pencil beam proton therapy for breast cancer
    Tommasino, F.
    Lorentini, S.
    Schwarz, M.
    Fellin, F.
    Farace, P.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S68 - S68
  • [25] Residual motion mitigation in scanned carbon ion beam therapy of liver tumors using enlarged pencil beam overlap
    Richter, Daniel
    Graeff, Christian
    Jaekel, Oliver
    Combs, Stephanie E.
    Durante, Marco
    Bert, Christoph
    RADIOTHERAPY AND ONCOLOGY, 2014, 113 (02) : 290 - 295
  • [26] Contour scanning for penumbra improvement in pencil beam scanned proton therapy
    Meier, G.
    Leiser, D.
    Besson, R.
    Mayor, A.
    Safai, S.
    Weber, D. C.
    Lomax, A. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (06): : 2398 - 2416
  • [27] Evaluating the Dosimetric Robustness of a Kv Independent CT Reconstruction Algorithm Via Measurement for Pencil Beam Scanned Proton Therapy
    Spivey, H.
    Weldon, M. D.
    Faught, A. M.
    Lee-Poprocki, H.
    MEDICAL PHYSICS, 2024, 51 (10) : 7808 - 7808
  • [28] Dosimetric comparison of the breath-hold based and conventional radiation therapy of lung cancer.
    Choi, A. H.
    Chung, K. Z.
    Park, B. S.
    Park, J. H.
    Pyo, H. R.
    Choi, B. K.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S560 - S560
  • [29] Clinical implementation of pencil beam scanning proton therapy for liver cancer with forced deep expiration breath hold
    Fracchiolla, Francesco
    Dionisi, Francesco
    Righetto, Roberto
    Widesott, Lamberto
    Giacomelli, Irene
    Cartechini, Giorgio
    Farace, Paolo
    Bertolini, Mattia
    Amichetti, Maurizio
    Schwarz, Marco
    RADIOTHERAPY AND ONCOLOGY, 2021, 154 : 137 - 144
  • [30] Dosimetric assessment of patient-specific breath-hold reproducibility on liver motion for SBRT planning
    Lu, Lan
    Ouyang, Zi
    Lin, Sara
    Mastroianni, Anthony
    Stephans, Kevin L.
    Xia, Ping
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (07): : 77 - 83