Monte Carlo study of photon fields from a flattening filter-free clinical accelerator

被引:90
|
作者
Vassiliev, ON [1 ]
Titt, U [1 ]
Kry, SF [1 ]
Pönisch, F [1 ]
Gillin, MT [1 ]
Mohan, R [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
10.1118/1.2174720
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In conventional clinical linear accelerators, the flattening filter scatters and absorbs a large fraction of primary photons. Increasing the beam-on time, which also increases the out-of-field exposure to patients, compensates for the reduction in photon fluence. In recent years, intensity modulated radiation therapy has been introduced, yielding better dose distributions than conventional three-dimensional conformal therapy. The drawback of this method is the further increase in beam-on time. An accelerator with the flattening filter removed, which would increase photon fluence greatly, could deliver considerably higher dose rates. The objective of the present study is to investigate the dosimetric properties of 6 and 18 MV photon beams from an accelerator without a flattening filter. The dosimetric data were generated using the Monte Carlo programs BEAMnrc and DOSXYZnrc. The accelerator model was based on the Varian Clinac 2100 design. We compared depth doses, dose rates, lateral profiles, doses outside collimation, total and collimator scatter factors for an accelerator with and without a flatteneing filter. The study showed that removing the filter increased the dose rate on the central axis by a factor of 2.31 (6 MV) and 5.45 (18 MV) at a given target current. Because the flattening filter is a major source of head scatter photons, its removal from the beam line could reduce the out-of-field dose. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:820 / 827
页数:8
相关论文
共 50 条
  • [21] Treatment vault shielding for a flattening filter-free medical linear accelerator
    Kry, Stephen F.
    Howell, Rebecca M.
    Polf, Jerimy
    Mohan, Radhe
    Vassiliev, Oleg N.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (05): : 1265 - 1273
  • [22] Monte-Carlo simulation of the Siemens Artiste linear accelerator flat 6 MV and flattening filter-free 7 MV beam line
    Sadrollahi, Alemeh
    Nuesken, Frank
    Licht, Norbert
    Ruebe, Christian
    Dzierma, Yvonne
    PLOS ONE, 2019, 14 (01):
  • [23] PHOTON BEAM CHARACTERISTICS AT MONITOR CHAMBER LEVEL IN A FLATTENING FILTER FREE LINAC: A MONTE CARLO STUDY
    Lind, M.
    Knoos, T.
    Ceberg, C.
    Wieslander, E.
    McClean, B.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S57 - S57
  • [24] Monte Carlo study of a free flattening filter to increase surface dose on 12 MV photon beam
    Zeghari, A.
    Saaidi, R.
    El Moursli, R. C.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (02): : 307 - 313
  • [25] Dose Enhancement for the Flattening-Filter-Free and Flattening-Filter Photon Beams in Nanoparticle-Enhanced Radiotherapy: A Monte Carlo Phantom Study
    Martelli, Stefano
    Chow, James C. L.
    NANOMATERIALS, 2020, 10 (04)
  • [26] On flattening filter-free portal dosimetry
    Pardo, Eduardo
    Castro Novais, Juan
    Molina Lopez, Maria Yolanda
    Ruiz Maqueda, Sheila
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 132 - 145
  • [27] The comparison of properties for radiotherapy with flattening filter-free and flattening filter beam
    Gu, J. H.
    Won, H. S.
    Hong, J. W.
    Chang, N. J.
    Park, J. H.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S978 - S978
  • [28] Dosimetric properties of 8 and 10 MV photon beams from a flattening filter free clinical accelerator
    Vassiliev, O.
    Titt, U.
    Gillin, M.
    Mohan, R.
    MEDICAL PHYSICS, 2006, 33 (06) : 2292 - 2292
  • [29] Acceptance criteria for flattening filter-free photon beam from standard medical electron linear accelerator: AERB task group recommendations
    Sahani, G.
    Sharma, S. D.
    Sharma, P. K. Dash
    Deshpande, D. D.
    Negi, P. S.
    Sathianarayanan, V. K.
    Rath, G. K.
    JOURNAL OF MEDICAL PHYSICS, 2014, 39 (04) : 206 - 211
  • [30] Commissioning of portal dosimetry using a novel method for flattening filter-free photon beam in a nontrue beam linear accelerator
    Gandhi, Arun
    Vellaiyan, Subramani
    Subramanian, V. S.
    Shanmugam, Thirumalaiswamy
    Murugesan, Kathirvel
    Subramanian, Kala
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (01) : 223 - 230