Wall correction factors, Pwall, for parallel-plate ionization chambers

被引:42
|
作者
Buckley, Lesley A. [1 ]
Rogers, D. W. O.
机构
[1] Carleton Univ, Ottawa Carleton Inst Phys, Ottawa, ON K1S 5B6, Canada
[2] Natl Res Council Canada, Ottawa, ON K1A 0R6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Monte Carlo; dosimetry; correction factor;
D O I
10.1118/1.2199988
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The EGSnrc Monte Carlo user-code CSnrc is used to calculate wall correction factors, P-wall, for parallel-plate ionization chambers in photon and electron beams. A set Of P-wall values, computed at the reference depth in water, is presented for several commonly used parallel-plate chambers. These values differ from the standard assumption of unity used by dosimetry protocols by up to 1.7% for clinical electron beams. Calculations also show that P-wall is strongly dependent on the depth of measurement and can vary by as much as 6% for a 6 MeV beam in moving from a depth of d(ref) to a depth of R-50, In photon beams, where there is limited information available regarding P-wall for parallel-plate chambers, CSnrc calculations show P-wall values of up to 2.4% at the reference depth over a range of photon energies. The P-wall values for photon beams are in good agreement with previous estimates of the wall correction but have much lower statistical uncertainties and cover a wider range of photon beam energies. (C) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:1788 / 1796
页数:9
相关论文
共 50 条
  • [21] APPROXIMATIONS TO SATURATION CURVES IN GAS-FILLED PARALLEL-PLATE IONIZATION CHAMBERS
    HEESE, RN
    PODGORSAK, EB
    FALLONE, BG
    MEDICAL PHYSICS, 1986, 13 (01) : 93 - 98
  • [22] APPROXIMATIONS TO SATURATION CURVES IN GAS-FILLED PARALLEL-PLATE IONIZATION CHAMBERS
    HEESE, R
    PODGORSAK, EB
    FALLONE, BG
    MEDICAL PHYSICS, 1986, 13 (04) : 570 - 570
  • [23] A method to increase the nominal range resolution of a stack of parallel-plate ionization chambers
    Rinaldi, I.
    Brons, S.
    Jaekel, O.
    Voss, B.
    Parodi, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (18): : 5501 - 5515
  • [24] An empirical method for the determination of Wall perturbation factors for parallel-plate chambers in high energy electron beams
    McEwen, M.
    Williams, A.
    Palmans, H.
    MEDICAL PHYSICS, 2006, 33 (06) : 2068 - 2068
  • [25] Experimental pwall and pcel correction factors for ionization chambers in low-energy clinical proton bearras
    Palmans, H
    Verhaegen, F
    Denis, JM
    Vynckier, S
    Thierens, H
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04): : 1187 - 1204
  • [26] Comparison of EGSnrc MC simulation of parallel-plate free air ionization chamber correction factors
    Wen Yuqin
    Wu Jinjie
    Wang Ji
    Lai Wanchang
    Zhao Liang
    Zhao Rui
    PROCEEDINGS OF 2019 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), 2019, : 973 - 978
  • [27] EXPERIMENTAL VALUES FOR PWALL,X AND PREPL,E FOR 5 PARALLEL-PLATE, ION CHAMBERS - A NEW ANALYSIS OF PREVIOUSLY PUBLISHED DATA
    KUCHNIR, FT
    REFT, CS
    MEDICAL PHYSICS, 1992, 19 (02) : 367 - 367
  • [28] Response of Parallel-Plate Ionization Chambers On the Buildup Dose Measurement in Inline Magnetic Fields
    Anami, N.
    Araki, F.
    Ohno, T.
    MEDICAL PHYSICS, 2020, 47 (06) : E844 - E844
  • [29] ELECTRON BACKSCATTER CORRECTIONS FOR PARALLEL-PLATE CHAMBERS
    HUNT, MA
    KUTCHER, GJ
    BUFFA, A
    MEDICAL PHYSICS, 1988, 15 (01) : 96 - 103
  • [30] A COMPARISON OF METHODS FOR CALIBRATING PARALLEL-PLATE CHAMBERS
    REFT, CS
    KUCHNIR, FT
    DEWERD, LA
    MICKA, J
    ATTIX, FH
    MEDICAL PHYSICS, 1994, 21 (12) : 1953 - 1957