Wall correction factors, Pwall, for parallel-plate ionization chambers

被引:42
|
作者
Buckley, Lesley A. [1 ]
Rogers, D. W. O.
机构
[1] Carleton Univ, Ottawa Carleton Inst Phys, Ottawa, ON K1S 5B6, Canada
[2] Natl Res Council Canada, Ottawa, ON K1A 0R6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Monte Carlo; dosimetry; correction factor;
D O I
10.1118/1.2199988
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The EGSnrc Monte Carlo user-code CSnrc is used to calculate wall correction factors, P-wall, for parallel-plate ionization chambers in photon and electron beams. A set Of P-wall values, computed at the reference depth in water, is presented for several commonly used parallel-plate chambers. These values differ from the standard assumption of unity used by dosimetry protocols by up to 1.7% for clinical electron beams. Calculations also show that P-wall is strongly dependent on the depth of measurement and can vary by as much as 6% for a 6 MeV beam in moving from a depth of d(ref) to a depth of R-50, In photon beams, where there is limited information available regarding P-wall for parallel-plate chambers, CSnrc calculations show P-wall values of up to 2.4% at the reference depth over a range of photon energies. The P-wall values for photon beams are in good agreement with previous estimates of the wall correction but have much lower statistical uncertainties and cover a wider range of photon beam energies. (C) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:1788 / 1796
页数:9
相关论文
共 50 条
  • [41] RESPONSE OF PARALLEL-PLATE ION CHAMBERS TO RADIATION PULSES
    LIVINGSTON, PM
    JOURNAL OF APPLIED PHYSICS, 1964, 35 (08) : 2341 - &
  • [42] PARALLEL-PLATE CHAMBERS - A FAST DETECTOR FOR IONIZING PARTICLES
    AREFIEV, A
    BENCZE, G
    BIZZETI, A
    CHOUMILOV, E
    CIVININI, C
    DALESSANDRO, R
    DALLSANTA, F
    DELLANEGRA, M
    FERRANDO, A
    FOUZ, MC
    HERVE, A
    IGLESIAS, A
    KOLOTAEV, Y
    MALININ, A
    MARTINEZLASO, L
    MESCHINI, M
    PEACH, D
    POJIDAEV, V
    RADERMACHER, E
    ROZJKOV, A
    SEEZ, C
    SZONCSO, F
    WROCHNA, G
    WULZ, CE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 318 - 323
  • [43] Dynamic shear stress in parallel-plate flow chambers
    Bacabac, RG
    Smit, TH
    Cowin, SC
    Van Loon, JJWA
    Nieuwstadt, FTM
    Heethaar, R
    Klein-Nulend, J
    JOURNAL OF BIOMECHANICS, 2005, 38 (01) : 159 - 167
  • [44] PARALLEL-PLATE CHAMBERS, A FAST DETECTOR FOR SUPERCOLLIDER EXPERIMENTS
    AREFIEV, A
    BIZZETI, A
    CIVININI, C
    CHOUMILOV, E
    DALESSANDRO, R
    FERRANDO, A
    MALININ, A
    MARTINEZLASO, L
    POJIDAEV, V
    NUCLEAR PHYSICS B, 1993, : 223 - 229
  • [45] LARGE PARALLEL-PLATE AVALANCHE CHAMBERS FOR MULTIPARTICLE TRACKING
    ANGELIS, ALS
    CLAESSON, G
    DONNI, P
    DURIEUX, E
    EKLUND, A
    GARPMAN, S
    GUSTAFSSON, HA
    IDH, J
    IZYCKI, M
    LOHNER, H
    LUND, I
    MARTIN, M
    NAEF, H
    NYSTRAND, J
    OSKARSSON, A
    OTTERLUND, I
    PERRIN, E
    ROSSELET, L
    RUBIO, JM
    SIEMSSEN, RH
    SLEGT, S
    SODERSTROM, K
    SOLOMEY, N
    STENLUND, E
    STER, A
    NUCLEAR PHYSICS A, 1994, 566 : C605 - C610
  • [46] EXPERIMENTAL-DETERMINATION OF FLUENCE PERTURBATION FACTORS FOR 5 PARALLEL-PLATE IONIZATION CHAMBERS (VOL 20, PG 331, 1993)
    KUCHNIR, FT
    REFT, CS
    MEDICAL PHYSICS, 1994, 21 (02) : 323 - 323
  • [48] Wall correction factors for calibration of plane-parallel ionization chambers with high-energy photon beams
    Araki, F
    Ikeda, R
    Shirakawa, Y
    Shimonobou, T
    Moribe, N
    Takada, T
    Takahashi, M
    Oura, H
    Matoba, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09): : 2509 - 2517
  • [50] COMMENTS ON THE EXPERIMENTAL-DETERMINATION OF THE REPLACEMENT CORRECTION FACTOR FOR PARALLEL-PLATE IONIZATION CHAMBERS IN HIGH-ENERGY ELECTRON-BEAMS - REPLY
    KUCHNIR, FT
    REFT, CS
    MEDICAL PHYSICS, 1993, 20 (03) : 743 - 743