Comparison of EGSnrc MC simulation of parallel-plate free air ionization chamber correction factors

被引:0
|
作者
Wen Yuqin [1 ,2 ]
Wu Jinjie [2 ]
Wang Ji [2 ]
Lai Wanchang [1 ]
Zhao Liang [2 ,3 ]
Zhao Rui [2 ]
机构
[1] Chengdu Univ Technol, Chengdu 610059, Peoples R China
[2] China Inst Metrol, Beijing 100029, Peoples R China
[3] Hebei Univ Sci & Technol, Shijiazhuang 050018, Peoples R China
关键词
Monka simulation; EGSnrc MC simulation; effective energy; air kerma;
D O I
10.1109/icemi46757.2019.9101814
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the continuous development of Monte Carlo simulation, it provides greater convenience for the reproducibility of X-ray air kerma. The DOSXYZnrc package in the EGSnrc MC simulation program is used to modify the electron loss, scattering fluorescence and pupil edge penetration of the X-ray free air ionization chamber. Monte Carlo simulation is performed by two different approaches. The comparative analysis reveals the use of phase space files. The deviation between the correction factors obtained by the simulation and the correction factors simulated by the effective energy as the single-energy X-ray is substantially within 0.09%, and the deviations of only 70 kV and 240 kV are respectively 0.15% and 0.3%. The results show that the correction factors obtained by Monte Carlo simulation of effective energy as single-energy X-ray can also be used to correct the air kerma energy. It is more convenient and fast to simulate the correction factors through effective energy.
引用
收藏
页码:973 / 978
页数:6
相关论文
共 50 条
  • [1] REPLACEMENT CORRECTION FACTORS FOR ELECTRON MEASUREMENTS WITH A PARALLEL-PLATE CHAMBER
    CASSON, H
    KILEY, JP
    MEDICAL PHYSICS, 1987, 14 (02) : 216 - 217
  • [2] Wall correction factors, Pwall, for parallel-plate ionization chambers
    Buckley, Lesley A.
    Rogers, D. W. O.
    MEDICAL PHYSICS, 2006, 33 (06) : 1788 - 1796
  • [3] Ion recombination correction for a parallel-plate ionization chamber in a carbon ion beam
    Rossomme, S.
    Hopfgartner, J.
    Delor, A.
    Fukumura, A.
    Vynckier, S.
    Palmans, H.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S420 - S421
  • [4] Attix free-air chamber correction factors computed using EGSnrc
    Stasko, John T.
    Culberson, Wesley S.
    MEDICAL PHYSICS, 2025,
  • [5] A STUDY OF PULSE SHAPES IN A PARALLEL-PLATE IONIZATION CHAMBER
    SHERR, R
    PETERSON, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1947, 18 (08): : 567 - 575
  • [6] SOME CHARACTERISTICS OF A GRIDDED PARALLEL-PLATE IONIZATION CHAMBER
    HERWIG, LO
    MILLER, GH
    UTTERBACK, NG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1955, 26 (10): : 929 - 936
  • [7] MEASUREMENT OF REPLACEMENT FACTORS FOR A PARALLEL-PLATE CHAMBER
    GOSWAMI, GC
    KASE, KR
    MEDICAL PHYSICS, 1989, 16 (05) : 791 - 793
  • [8] FIELD DISTORTION IN A PARALLEL-PLATE FREE-AIR CHAMBER - A COMPENSATORY EFFECT
    KEMP, LAW
    READ, LR
    WOODALL, JE
    PHYSICS IN MEDICINE AND BIOLOGY, 1968, 13 (01): : 91 - &
  • [9] Characteristics of a miniature parallel-plate free-air ionization chamber for measuring the intensity of synchrotron radiation from an undulator
    Nariyama, N
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (09): : 2860 - 2862
  • [10] A new extended-length parallel-plate ionization chamber
    Maia, AF
    Caldas, LVE
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16): : 3837 - 3847