Clinical Evaluation of the New Amplatzer Duct Occluder II for Patent Arterial Duct Occlusion

被引:22
|
作者
Bhole, V. [1 ]
Miller, P. [1 ]
Mehta, C. [2 ]
Stumper, O. [1 ]
Reinhardt, Z. [1 ]
De Giovanni, J. V. [1 ]
机构
[1] Birmingham Childrens Hosp, Heart Unit, Birmingham B4 6NH, W Midlands, England
[2] Alder Hey Childrens Hosp, Dept Cardiol, Liverpool L12 2AP, Merseyside, England
关键词
device closure; Amplatzer ADO II; cardiac catheterization; patent arterial duct; TRANSCATHETER CLOSURE; EXPERIENCE; DEVICE; COILS; IMMEDIATE;
D O I
10.1002/ccd.22095
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Several devices such as coils and Amplatzer duct occluder (ADO) are used for catheter closure of patent arterial ducts (PDA). These carry a high success rate but residual shunts, suboptimal device orientation, and technical problems are encountered. The Amplatzer duct occluder II (ADO II) is designed to address these limitations. Objectives: To evaluate the technical features of the new ADO II device for PDA closure and document the immediate/early closure rate, complications and device behavior during implantation. Methods: Prospective, two center study from February 2008 to January 2009. Twenty-seven patients (18 females) received the ADO II The median age was 22 months (range: 7 months-68 years) and the median weight was 11.7 kg (range: 6.9-108). The median PDA diameter was 2.6 mm (range: 1-4.4). The approach was arterial in 13 and venous in 14 patients. Follow-up included echocardiography at 1 day and 1 month postimplantation. Results: All implantations were technically successful with immediate complete angiographic closure in 21 and trivial contrast flow in six patients. The median procedure time was 43 min (range: 15-82) and the fluoroscopy time was 6 min (range: 2.2-26.5). Echocardiography confirmed no residual shunts on the following day. There were no complications. Conclusion: The new ADO II is a versatile and very effective device for closure of PDAs of various shapes, lengths, and up to diameters of 5.5 mm. The disc articulations, high early closure rate, arterial or venous approach options, and small diameter delivery catheter are all beneficial features. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:762 / 769
页数:8
相关论文
共 50 条
  • [31] Successful occlusion of a coronary arteriovenous fistula using an Amplatzer™ duct occluder
    Sadiq, M
    Wilkinson, JL
    Qureshi, SA
    CARDIOLOGY IN THE YOUNG, 2001, 11 (01) : 84 - 87
  • [32] A novel use of Amplatzer duct occluder
    Amin, Z
    Leatherbury, L
    Moore, HV
    Strong, WB
    PEDIATRIC CARDIOLOGY, 2000, 21 (02) : 180 - 182
  • [33] A Novel Use of Amplatzer Duct Occluder
    Z. Amin
    L. Leatherbury
    H.V. Moore
    W.B. Strong
    Pediatric Cardiology, 2000, 21 : 180 - 182
  • [34] Initial clinical experience in transcatheter closure of large patent arterial ducts in infants using the modified and angled Amplatzer duct occluder
    Viayalakshmi, Ishwarappa B.
    Chitra, Narasimhan
    Rajasri, Ravindran
    Vasudevan, Karthik
    CARDIOLOGY IN THE YOUNG, 2006, 16 (04) : 378 - 384
  • [35] Amplatzer duct occluder ii for closure of congenital Gerbode defects
    Vijayalakshmi, I. B.
    Setty, H. S. Natraj
    Chitra, Narasimhan
    Manjunath, Cholenahally N.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 86 (06) : 1057 - 1062
  • [36] Closure of an Aortopulmonary Window Using the Amplatzer Duct Occluder II
    Noonan, Patrick M. E.
    Desai, Tarak
    DeGiovanni, Joseph V.
    PEDIATRIC CARDIOLOGY, 2013, 34 (03) : 712 - 714
  • [37] Closure of an Aortopulmonary Window Using the Amplatzer Duct Occluder II
    Patrick M. E. Noonan
    Tarak Desai
    Joseph V. DeGiovanni
    Pediatric Cardiology, 2013, 34 : 712 - 714
  • [38] Fontan Fenestration Closure With Amplatzer Duct Occluder II Device
    McCrossan, B. A.
    Walsh, K. P.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (05) : 837 - 841
  • [39] Transcatheter closure of patent ductus arteriosus in infants using the Amplatzer duct occluder
    Fischer, G
    Kramer, HH
    Uebing, A
    Renaud, C
    Grabitz, R
    EUROPEAN HEART JOURNAL, 2001, 22 : 418 - 418
  • [40] Transcatheter closure of moderate to large patent ductus arteriosus with the amplatzer duct occluder
    Wang, Jou-Kou
    Wu, Mei-Hwan
    Hwang, Juey-Jen
    Chiang, Fu-Tein
    Lin, Ming-Tai
    Lue, Hung-Chi
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (04) : 572 - 578