Clinical Evaluation of the New Amplatzer Duct Occluder II for Patent Arterial Duct Occlusion

被引:22
|
作者
Bhole, V. [1 ]
Miller, P. [1 ]
Mehta, C. [2 ]
Stumper, O. [1 ]
Reinhardt, Z. [1 ]
De Giovanni, J. V. [1 ]
机构
[1] Birmingham Childrens Hosp, Heart Unit, Birmingham B4 6NH, W Midlands, England
[2] Alder Hey Childrens Hosp, Dept Cardiol, Liverpool L12 2AP, Merseyside, England
关键词
device closure; Amplatzer ADO II; cardiac catheterization; patent arterial duct; TRANSCATHETER CLOSURE; EXPERIENCE; DEVICE; COILS; IMMEDIATE;
D O I
10.1002/ccd.22095
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Several devices such as coils and Amplatzer duct occluder (ADO) are used for catheter closure of patent arterial ducts (PDA). These carry a high success rate but residual shunts, suboptimal device orientation, and technical problems are encountered. The Amplatzer duct occluder II (ADO II) is designed to address these limitations. Objectives: To evaluate the technical features of the new ADO II device for PDA closure and document the immediate/early closure rate, complications and device behavior during implantation. Methods: Prospective, two center study from February 2008 to January 2009. Twenty-seven patients (18 females) received the ADO II The median age was 22 months (range: 7 months-68 years) and the median weight was 11.7 kg (range: 6.9-108). The median PDA diameter was 2.6 mm (range: 1-4.4). The approach was arterial in 13 and venous in 14 patients. Follow-up included echocardiography at 1 day and 1 month postimplantation. Results: All implantations were technically successful with immediate complete angiographic closure in 21 and trivial contrast flow in six patients. The median procedure time was 43 min (range: 15-82) and the fluoroscopy time was 6 min (range: 2.2-26.5). Echocardiography confirmed no residual shunts on the following day. There were no complications. Conclusion: The new ADO II is a versatile and very effective device for closure of PDAs of various shapes, lengths, and up to diameters of 5.5 mm. The disc articulations, high early closure rate, arterial or venous approach options, and small diameter delivery catheter are all beneficial features. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:762 / 769
页数:8
相关论文
共 50 条
  • [21] Single-Center Experience in Percutaneous Closure of Arterial Duct with Amplatzer Duct Occluder II Additional Sizes
    Mahmoud, Heba Talat
    Santoro, Giuseppe
    Gaio, Gianpiero
    D'Aiello, Fabio Angelo
    Capogrosso, Cristina
    Palladino, Maria Teresa
    Russo, Maria Giovanna
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 89 (06) : 1045 - 1050
  • [22] THE CLINICAL EVALUATION OF TRANSCATHETER CLOSURE OF PERIMEMBRANOUS VENTRICULAR SEPTAL DEFECTS WITH THE AMPLATZER DUCT OCCLUDER II
    Yu Zhiqing
    Fu Lijun
    Li Yun
    Zhang Yuqi
    Li Fen
    Huang Meirong
    Guo Ying
    HEART, 2011, 97
  • [23] First experience with the Amplatzer duct occluder type II
    Jux, C.
    Haas, N.
    Schaeffler, R.
    Matthies, W.
    Kececioglu, D.
    CLINICAL RESEARCH IN CARDIOLOGY, 2008, 97 (09) : 695 - 695
  • [24] Echocardiographic findings before and after interventional occlusion of persistently patent ductus arteriosus with the Amplatzer duct occluder®.
    Rauch, R
    Koch, A
    Buheitel, G
    Kumpf, M
    Sieverding, L
    Breuer, J
    Singer, H
    Hofbeck, M
    ULTRASCHALL IN DER MEDIZIN, 2001, 22 (06): : 279 - 283
  • [25] Transcatheter closure of patent ductus arteriosus with the Amplatzer Duct Occluder.
    Saliba, Z
    Aggoun, Y
    Hausse, AO
    Acar, P
    Bonnet, D
    Fraisse, A
    Sidi, D
    Kachaner, J
    Bonhoeffer, P
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2000, 93 (05): : 533 - 538
  • [26] Live 3D image overlay for arterial duct closure with Amplatzer Duct Occluder II additional size
    Goreczny, Sebstian
    Morgan, Gareth J.
    Dryzek, Pawel
    CARDIOLOGY IN THE YOUNG, 2016, 26 (03) : 605 - 608
  • [27] Transcatheter closure of the patent ductus arteriosus using the new Amplatzer duct occluder: Initial clinical applications in children
    Thanopoulos, Basil
    Eleftherakis, Nikolaos
    Tzannos, Konstantinos
    Stefanadis, Christodoulos
    AMERICAN HEART JOURNAL, 2008, 156 (05) : 917 - 917
  • [28] Long-Term Clinical Experience With Amplatzer Ductal Occluder II for Closure of the Persistent Arterial Duct in Children
    Kang, Sok-Leng
    Morgan, Gareth
    Forsey, Jonathan
    Tometzki, Andrew
    Martin, Robin
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (07) : 1102 - 1108
  • [29] Transcatheter occlusion of the ruptured sinus of Valsalva aneurysm with an Amplatzer duct occluder
    Zhao, Shi-Hua
    Yan, Chao-Wu
    Zhu, Xian-Yang
    Li, Jian-Jun
    Xu, Nai-Xun
    Jiang, Shi-Linag
    Xu, Zhong-Ying
    Wang, Cheng
    Wu, Wen-Hui
    Hai-Bo, Hu
    Li, Shi-Guo
    Ye, Zan-Kai
    Wang, Hao
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 129 (01) : 81 - 85
  • [30] The Amplatzer Duct Occluder II: A New Device for Percutaneous Ductus Arteriosus Closure
    Saliba, Zakhia
    El-Rassi, Issam
    Abi-Warde, Marie-Therese
    Chehab, Ghassan
    Daou, Linda
    Khater, Daniele
    Gerbaka, Bernard
    Jebara, Victor
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2009, 22 (06) : 496 - 502