Fontan Fenestration Closure With Amplatzer Duct Occluder II Device

被引:4
|
作者
McCrossan, B. A. [1 ]
Walsh, K. P. [1 ]
机构
[1] Our Ladys Childrens Hosp, Dept Paediat Cardiol, Dublin 12, Ireland
关键词
congenital heart disease; pediatrics; interventional devices; innovation; imaging; angiographic; fluoroscopic; TRANSCATHETER CLOSURE; EXTRACARDIAC FONTAN; VASCULAR PLUG; OPERATION; OCCLUSION;
D O I
10.1002/ccd.25770
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesTo evaluate Fontan fenestration closure using the Amplatzer Duct Occluder II device (ADO2). BackgroundFontan fenestration closure is a well established catheter intervention. A range of occlusion devices developed for other interventions have been utilized. Most of these devices, and especially the most commonly used Amplatzer Septal Occluder, are relatively bulky. The ADO2 is a low profile, flexible, and inexpensive device which seems well suited to the Fontan fenestration. MethodsThis study details retrospective review of patients undergoing Fontan fenestration closure with an ADO2 device. Outcome measures included procedural success, pre- and post-procedural differences in oxygen saturation and mean pulmonary artery pressure and complications. ResultsThirteen patients were eligible for inclusion during the 34 month study period. All procedures were technically successful. There was a significant increase in oxygen saturations (Mean=+12%, P<0.01) after fenestration closure but no significant change in mean pulmonary artery pressure (Mean=+0.5 mm Hg, P=0.08). There were no procedural complications. ConclusionFontan fenestration closure with the ADO2 device is a simple, short, and cost-effective procedure. The ADO2 characteristics recommend it to occlusion of varying sizes and morphologies of Fontan fenestration. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:837 / 841
页数:5
相关论文
共 50 条
  • [1] Closure of the fenestration in the extracardiac Fontan with the Amplatzer duct occluder device
    Rueda, F
    Squitieri, C
    Ballerini, L
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 54 (01) : 88 - 92
  • [2] Closure of extracardiac Fontan fenestration by using the Amplatzer duct occluder
    Boudjemline, Y
    Bonnet, D
    Sidi, D
    Agnoletti, G
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2005, 98 (05): : 449 - 454
  • [3] Fontan fenestration closure using the amplatzer septal occluder
    Cowley, CG
    Badran, S
    Rocchini, AP
    Lloyd, TR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 498A - 498A
  • [4] Closure of Aortopulmonary Window with Amplatzer Duct Occluder Device
    M. Atiq
    N. Rashid
    K.A. Kazmi
    S.A. Qureshi
    Pediatric Cardiology, 2003, 24 : 298 - 299
  • [5] Closure of aortopulmonary window with amplatzer duct occluder device
    Atiq, M
    Rashid, N
    Kazmi, KA
    Qureshi, SA
    PEDIATRIC CARDIOLOGY, 2003, 24 (03) : 298 - 299
  • [6] The Amplatzer Duct Occluder II: A New Device for Percutaneous Ductus Arteriosus Closure
    Saliba, Zakhia
    El-Rassi, Issam
    Abi-Warde, Marie-Therese
    Chehab, Ghassan
    Daou, Linda
    Khater, Daniele
    Gerbaka, Bernard
    Jebara, Victor
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2009, 22 (06) : 496 - 502
  • [7] Successful closure of coronary artery fistula with an Amplatzer Duct Occluder II device
    Ece, Ibrahim
    Ture, Mehmet
    Uner, Abdurrahman
    Sahin, Musa
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 24 (04): : 752 - 754
  • [8] Using the Amplatzer™ Septal Occluder to occlude fontan fenestration
    Coe, JY
    Dyck, JD
    Olley, PM
    Harder, J
    PEDIATRIC RESEARCH, 2000, 47 (04) : 40A - 40A
  • [9] Fenestration closure with Amplatzer Duct Occluder II in patients after total cavo-pulmonary connection
    Goreczny, Sebastian
    Dryzek, Pawet
    Morgan, Gareth J.
    Mazurek-Kula, Anna
    Moll, Jacek J.
    Moll, Jadwiga A.
    Qureshi, Shakeel
    Moszura, Tomasz
    ARCHIVES OF MEDICAL SCIENCE, 2017, 13 (02) : 337 - 345
  • [10] Transcatheter Closure of Extracardiac Fontan Fenestration by Using Amplazter Duct or Septal Occluder
    Li, S. G.
    Jiang, S. L.
    Xu, Z. Y.
    Zhao, S. H.
    Jin, J. L.
    CARDIOLOGY, 2010, 117 : 115 - 115