Fontan Fenestration Closure With Amplatzer Duct Occluder II Device

被引:4
|
作者
McCrossan, B. A. [1 ]
Walsh, K. P. [1 ]
机构
[1] Our Ladys Childrens Hosp, Dept Paediat Cardiol, Dublin 12, Ireland
关键词
congenital heart disease; pediatrics; interventional devices; innovation; imaging; angiographic; fluoroscopic; TRANSCATHETER CLOSURE; EXTRACARDIAC FONTAN; VASCULAR PLUG; OPERATION; OCCLUSION;
D O I
10.1002/ccd.25770
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesTo evaluate Fontan fenestration closure using the Amplatzer Duct Occluder II device (ADO2). BackgroundFontan fenestration closure is a well established catheter intervention. A range of occlusion devices developed for other interventions have been utilized. Most of these devices, and especially the most commonly used Amplatzer Septal Occluder, are relatively bulky. The ADO2 is a low profile, flexible, and inexpensive device which seems well suited to the Fontan fenestration. MethodsThis study details retrospective review of patients undergoing Fontan fenestration closure with an ADO2 device. Outcome measures included procedural success, pre- and post-procedural differences in oxygen saturation and mean pulmonary artery pressure and complications. ResultsThirteen patients were eligible for inclusion during the 34 month study period. All procedures were technically successful. There was a significant increase in oxygen saturations (Mean=+12%, P<0.01) after fenestration closure but no significant change in mean pulmonary artery pressure (Mean=+0.5 mm Hg, P=0.08). There were no procedural complications. ConclusionFontan fenestration closure with the ADO2 device is a simple, short, and cost-effective procedure. The ADO2 characteristics recommend it to occlusion of varying sizes and morphologies of Fontan fenestration. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:837 / 841
页数:5
相关论文
共 50 条
  • [41] Transcatheter closure of ventricular septal defects using the Amplatzer Duct Occluder II device: a single-center experience
    Polat, Tugcin Bora
    Turkmen, Esma
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2016, 12 (04): : 340 - 347
  • [42] PERCUTANEOUS TRANSCATHETER CLOSURE OF PROSTHETIC PARAVALVULAR LEAKS USING AMPLATZER DUCT OCCLUDER II
    Kursaklioglu, Hurkan
    Barcin, Cem
    Baysan, Oben
    Iyisoy, Atila
    Bugan, Baris
    Kose, Sedat
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 140 : S4 - S4
  • [43] Transcatheter Closure of Perimembranous Ventricular Septal Defect Using the Amplatzer Duct Occluder II
    Sun, Hongxiao
    Luo, Gang
    Du, Zhanhui
    Ji, Zhixian
    Pan, Silin
    CONGENITAL HEART DISEASE, 2021, 16 (02) : 151 - 157
  • [44] Transcatheter closure of coronary artery fistula with an Amplatzer Duct Occluder II in a symptomatic infant
    Karagoz, Tevfik
    Yildirim, Isil
    Celiker, Alpay
    ANADOLU KARDIYOLOJI DERGISI-THE ANATOLIAN JOURNAL OF CARDIOLOGY, 2011, 11 (03): : 274 - 275
  • [45] TRANSCATHETER CLOSURE OF A BLALOCK-TAUSSIG SHUNT WITH THE AMPLATZER DUCT OCCLUDER-II
    Baykan, Ali
    Sezer, Sadettin
    Onan, Sertac Hanedan
    Uzum, Kazim
    Narin, Nazmi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 140 : S85 - S85
  • [46] Transcatheter Closure of Large Sized Patent Ductus Arteriosus Using the Amplatzer Duct Occluder Device
    Shabbir, Muhammad
    Akhtar, Khurram
    Maadullah
    Ahmed, Waqar
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2009, 19 (05): : 275 - 278
  • [47] Amplatzer® septal occluder device for closure of aortic pseudoaneurysms
    Jolly, Neeraj
    Garg, Ravi Kumar
    Raman, Jaishankar
    Hijazi, Ziyad M.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 70 (04) : 619 - 620
  • [48] Aorto-left ventricular tunnel: Transcatheter closure using an Amplatzer duct occluder device
    Chessa, M
    Chaudhari, M
    De Giovanni, JV
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (02): : 253 - 254
  • [49] Successful coronary artery fistula closure using Amplatzer duct occluder II device in a 10-months-old infant
    Faisal, Aulia
    Hidayat, Taufiq
    Rahman, Mahrus Ahmad
    Utamayasa, Alit
    BALI MEDICAL JOURNAL, 2023, 12 (02) : 2284 - 2288
  • [50] Late-Term Displacement of Amplatzer Duct Occluder II Device Following Percutaneous Closure of Patent Ductus Arteriosus in an Adult
    Barcin, Cem
    Kursaklioglu, Hurkan
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2010, 23 (04) : 368 - 369