Porosity measurements by X-ray computed tomography: Accuracy evaluation using a calibrated object

被引:48
|
作者
Hermanek, Petr [1 ]
Carmignato, Simone [1 ]
机构
[1] Univ Padua, Dept Management & Engn DTG, Stradella San Nicola 3, I-36100 Vicenza, Italy
关键词
X-ray computed tomography; Dimensional metrology; Reference object; Internal defects; Simulations; VOIDS; FATIGUE; CARBON/EPOXY; COMPOSITES; STRENGTH; ALLOYS; PARTS;
D O I
10.1016/j.precisioneng.2017.03.007
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Accurate identification and measurement of internal voids and porosity is an important step towards improvement of production processes to obtain high quality materials and products. Recently, the importance of knowing the exact size, shape, volume and location of defects has become even higher as tighter requirements and new standards have been introduced in industry. There are several well-established methods for defects evaluation based on various principles (both destructive and non-destructive). However, all conventional methods have various deficiencies and the information about internal voids/porosity that can be extracted is limited. Most of these drawbacks can be overcome by using X-ray computed tomography (CT). Unlike other methods, CT provides full three-dimensional information about shape, size and distribution of internal voids and porosity; however, the accuracy of measurements is still under investigation. Hence, further evaluations on CT porosity measurements must be performed in order to consider X-ray computed tomography a reliable instrument for the assessment and detection of internal defects. A reference object with artificial defects was used in this research work in order to evaluate the accuracy of porosity measurements by CT. The reference object was manufactured by ultra-precision micro milling. The object contains dismountable components with embedded internal hemispherical features that simulate internal porosity. The artificial porosity was micro-milled on top surfaces of dismountable cylindrical inserts. The hemispherical calottes were thereafter calibrated by traceable coordinate measuring systems and calibrated values were compared to actual values measured by a CT system. The accuracy of CT porosity measurements was then evaluated based on results obtained on various measurands, using different software tools and measuring procedures, comparing real scans to numerical simulations and investigating the influence of CT system parameters settings on measurement results. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:377 / 387
页数:11
相关论文
共 50 条
  • [41] VIRTUAL UNROLLING USING X-RAY COMPUTED TOMOGRAPHY
    Allegra, D.
    Ciliberto, E.
    Ciliberto, P.
    Milotta, F. L. M.
    Petrillo, G.
    Stanco, F.
    Trombatore, C.
    2015 23RD EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2015, : 2864 - 2868
  • [42] Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography
    Zappala, Susan
    Helliwell, Jonathan R.
    Tracy, Saoirse R.
    Mairhofer, Stefan
    Sturrock, Craig J.
    Pridmore, Tony
    Bennett, Malcolm
    Mooney, Sacha J.
    PLOS ONE, 2013, 8 (06):
  • [43] Nondestructive investigation on close and open porosity of additively manufactured parts using an X-ray computed tomography
    Wang S.
    Qu H.
    Yu S.
    Xia Zhang S.
    Materials Today: Proceedings, 2022, 70 : 124 - 130
  • [44] CHARACTERIZATION OF AIR ENTRAINED CONCRETE POROSITY USING X-RAY COMPUTED MICRO TOMOGRAPHY IMAGE ANALYSIS
    Razakamandimby, D. F. Tiana
    Park, Kyoungsoo
    BRITTLE MATRIX COMPOSITES 12, 2019, : 139 - 146
  • [45] High spatial resolution x-ray luminescence computed tomography and x-ray fluorescence computed tomography
    Dai, Xianjin
    Sivasubramanian, Kathyayini
    Xing, Lei
    MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS V, 2019, 10862
  • [46] Contribution of X-ray computed tomography in the evaluation of kidney performance
    Lemoine, Sandrine
    Rognant, Nicolas
    Collet-Benzaquen, Diane
    Juillard, Laurent
    NEPHROLOGIE & THERAPEUTIQUE, 2012, 8 (04): : 206 - 211
  • [47] Evaluation of Computed Tomography X-Ray Beam Dose Profiles
    Civa, Lejla M.
    Beganovic, Adnan
    Redzic, Mahira
    Lasic, Ivan
    Gazdic-Santic, Maja
    Skopljak-Beganovic, Amra
    Jasic, Rahima
    Vegar-Zubovic, Sandra
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, CMBEBIH 2019, 2020, 73 : 137 - 141
  • [48] X-ray computed tomography for internal quality evaluation of peaches
    Barcelon, EG
    Tojo, S
    Watanabe, K
    JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1999, 73 (04): : 323 - 330
  • [49] Evaluation of X-ray doses in paediatrics multislice computed tomography
    Khajmi, H.
    Nouh, F. A.
    Tounsi, A.
    Touti, R.
    RADIOPROTECTION, 2023, 58 (04) : 303 - 308
  • [50] Effect of the number of projections on dimensional measurements with X-ray computed tomography
    Villarraga-Gomez, Herminso
    Smith, Stuart T.
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2020, 66 : 445 - 456