Porosity measurements by X-ray computed tomography: Accuracy evaluation using a calibrated object

被引:48
|
作者
Hermanek, Petr [1 ]
Carmignato, Simone [1 ]
机构
[1] Univ Padua, Dept Management & Engn DTG, Stradella San Nicola 3, I-36100 Vicenza, Italy
来源
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY | 2017年 / 49卷
关键词
X-ray computed tomography; Dimensional metrology; Reference object; Internal defects; Simulations; VOIDS; FATIGUE; CARBON/EPOXY; COMPOSITES; STRENGTH; ALLOYS; PARTS;
D O I
10.1016/j.precisioneng.2017.03.007
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Accurate identification and measurement of internal voids and porosity is an important step towards improvement of production processes to obtain high quality materials and products. Recently, the importance of knowing the exact size, shape, volume and location of defects has become even higher as tighter requirements and new standards have been introduced in industry. There are several well-established methods for defects evaluation based on various principles (both destructive and non-destructive). However, all conventional methods have various deficiencies and the information about internal voids/porosity that can be extracted is limited. Most of these drawbacks can be overcome by using X-ray computed tomography (CT). Unlike other methods, CT provides full three-dimensional information about shape, size and distribution of internal voids and porosity; however, the accuracy of measurements is still under investigation. Hence, further evaluations on CT porosity measurements must be performed in order to consider X-ray computed tomography a reliable instrument for the assessment and detection of internal defects. A reference object with artificial defects was used in this research work in order to evaluate the accuracy of porosity measurements by CT. The reference object was manufactured by ultra-precision micro milling. The object contains dismountable components with embedded internal hemispherical features that simulate internal porosity. The artificial porosity was micro-milled on top surfaces of dismountable cylindrical inserts. The hemispherical calottes were thereafter calibrated by traceable coordinate measuring systems and calibrated values were compared to actual values measured by a CT system. The accuracy of CT porosity measurements was then evaluated based on results obtained on various measurands, using different software tools and measuring procedures, comparing real scans to numerical simulations and investigating the influence of CT system parameters settings on measurement results. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:377 / 387
页数:11
相关论文
共 50 条
  • [11] X-ray computed tomography and mercury porosimetry for evaluation of density evolution and porosity distribution
    Lu, PZ
    Lannutti, JJ
    Klobes, P
    Meyer, K
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2000, 83 (03) : 518 - 522
  • [12] APPLICATION OF X-RAY COMPUTED TOMOGRAPHY IN THE EVALUATION OF SOIL POROSITY IN SOIL MANAGEMENT SYSTEMS
    Beraldo, Jose M. G.
    Scannavino Junior, Francisco De A.
    Cruvinel, Paulo E.
    ENGENHARIA AGRICOLA, 2014, 34 (06): : 1162 - 1174
  • [13] Dimensional accuracy in X-ray computed tomography imaging
    Neel, ST
    Gibson, R
    Daniels, CR
    Klosterman, EL
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 17A AND 17B, 1998, : 411 - 418
  • [14] Analysis of Vesicular Porosity in Soils using High Resolution X-Ray Computed Tomography
    Turk, Judith K.
    Graham, Robert C.
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2014, 78 (03) : 868 - 880
  • [15] ASSESSMENT OF ACCURACY OF FIBRE ORIENTATION MEASUREMENT USING X-RAY COMPUTED TOMOGRAPHY
    Salaberger, D.
    Hine, P. J.
    Jerabek, M.
    Kastner, J.
    20TH INTERNATIONAL CONFERENCE ON COMPOSITE MATERIALS, 2015,
  • [16] X-ray computed tomography using projection X-ray microscope
    Yoshimura, F
    Miyata, C
    Kuzuryu, C
    Hori, A
    Obi, T
    Ohyama, N
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 166 - 171
  • [17] Fruit Microstructure Evaluation Using Synchrotron X-Ray Computed Tomography
    Verboven, Pieter
    Ho, Quang Tri
    Herremans, Els
    Mebatsion, Hibru Kelemu
    Nicolai, Bart
    Kerckhofs, Greet
    Wevers, Martine
    Cloetens, Peter
    FOOD ENGINEERING INTERFACES, 2011, : 589 - +
  • [18] Characterization of porosity and defects on composite materials using X-ray computed tomography and image processing
    Trolli, Alessio
    Casaccia, Sara
    Pandarese, Giuseppe
    Revel, Gian Marco
    2021 IEEE 8TH INTERNATIONAL WORKSHOP ON METROLOGY FOR AEROSPACE (IEEE METROAEROSPACE), 2021, : 479 - 484
  • [19] Evaluation of Concrete Elements with X-Ray Computed Tomography
    Balazs, Gyorgy L.
    Lubloy, Eva
    Foldes, Tamas
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2018, 30 (09)
  • [20] X-ray luminescence computed tomography using a focused x-ray beam
    Zhang, Wei
    Lun, Michael C.
    Nguyen, Alex Anh-Tu
    Li, Changqing
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)