Porosity measurements by X-ray computed tomography: Accuracy evaluation using a calibrated object

被引:48
|
作者
Hermanek, Petr [1 ]
Carmignato, Simone [1 ]
机构
[1] Univ Padua, Dept Management & Engn DTG, Stradella San Nicola 3, I-36100 Vicenza, Italy
来源
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY | 2017年 / 49卷
关键词
X-ray computed tomography; Dimensional metrology; Reference object; Internal defects; Simulations; VOIDS; FATIGUE; CARBON/EPOXY; COMPOSITES; STRENGTH; ALLOYS; PARTS;
D O I
10.1016/j.precisioneng.2017.03.007
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Accurate identification and measurement of internal voids and porosity is an important step towards improvement of production processes to obtain high quality materials and products. Recently, the importance of knowing the exact size, shape, volume and location of defects has become even higher as tighter requirements and new standards have been introduced in industry. There are several well-established methods for defects evaluation based on various principles (both destructive and non-destructive). However, all conventional methods have various deficiencies and the information about internal voids/porosity that can be extracted is limited. Most of these drawbacks can be overcome by using X-ray computed tomography (CT). Unlike other methods, CT provides full three-dimensional information about shape, size and distribution of internal voids and porosity; however, the accuracy of measurements is still under investigation. Hence, further evaluations on CT porosity measurements must be performed in order to consider X-ray computed tomography a reliable instrument for the assessment and detection of internal defects. A reference object with artificial defects was used in this research work in order to evaluate the accuracy of porosity measurements by CT. The reference object was manufactured by ultra-precision micro milling. The object contains dismountable components with embedded internal hemispherical features that simulate internal porosity. The artificial porosity was micro-milled on top surfaces of dismountable cylindrical inserts. The hemispherical calottes were thereafter calibrated by traceable coordinate measuring systems and calibrated values were compared to actual values measured by a CT system. The accuracy of CT porosity measurements was then evaluated based on results obtained on various measurands, using different software tools and measuring procedures, comparing real scans to numerical simulations and investigating the influence of CT system parameters settings on measurement results. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:377 / 387
页数:11
相关论文
共 50 条
  • [21] Estimation of the density of pomegranate fruit and their fractions using X-ray computed tomography calibrated with polymeric materials
    Arendse, Ebrahiema
    Fawole, Olaniyi Amos
    Magwaza, Lembe Samukelo
    Opara, Umezuruike Linus
    BIOSYSTEMS ENGINEERING, 2016, 148 : 148 - 156
  • [22] X-ray computed tomography
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13): : R29 - R43
  • [23] X-RAY COMPUTED TOMOGRAPHY
    HORN, E
    ELECTRONICS AND POWER, 1978, 24 (01): : 36 - 41
  • [24] X-ray computed tomography
    不详
    NATURE REVIEWS METHODS PRIMERS, 2021, 1 (01):
  • [25] X-ray computed tomography
    Nature Reviews Methods Primers, 1
  • [26] X-RAY COMPUTED TOMOGRAPHY
    HORN, E
    ELECTRONICS AND POWER, 1978, 24 (03): : 181 - 181
  • [27] Evaluation of joined silicon nitride by X-ray computed tomography (X-ray CT)
    Kondo, Naoki
    Nishimura, Yoshihiro
    Suzuki, Takayuki
    Kita, Hideki
    JOURNAL OF THE CERAMIC SOCIETY OF JAPAN, 2010, 118 (1384) : 1192 - 1194
  • [28] Object Specific Trajectory Optimization for Industrial X-ray Computed Tomography
    Fischer, Andreas
    Lasser, Tobias
    Schrapp, Michael
    Stephan, Juergen
    Noel, Peter B.
    SCIENTIFIC REPORTS, 2016, 6
  • [29] Object Specific Trajectory Optimization for Industrial X-ray Computed Tomography
    Andreas Fischer
    Tobias Lasser
    Michael Schrapp
    Jürgen Stephan
    Peter B. Noël
    Scientific Reports, 6
  • [30] Evaluation of X-ray computed tomography for surface texture measurements using a prototype additively manufactured reference standard
    Sun, Wenjuan
    Chen, Xiao
    Giusca, Claudiu
    Lou, Shan
    Jones, Christopher W.
    Boulter, Hal
    Brown, Stephen
    e-Journal of Nondestructive Testing, 2022, 27 (03):