Porosity measurements by X-ray computed tomography: Accuracy evaluation using a calibrated object

被引:48
|
作者
Hermanek, Petr [1 ]
Carmignato, Simone [1 ]
机构
[1] Univ Padua, Dept Management & Engn DTG, Stradella San Nicola 3, I-36100 Vicenza, Italy
关键词
X-ray computed tomography; Dimensional metrology; Reference object; Internal defects; Simulations; VOIDS; FATIGUE; CARBON/EPOXY; COMPOSITES; STRENGTH; ALLOYS; PARTS;
D O I
10.1016/j.precisioneng.2017.03.007
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Accurate identification and measurement of internal voids and porosity is an important step towards improvement of production processes to obtain high quality materials and products. Recently, the importance of knowing the exact size, shape, volume and location of defects has become even higher as tighter requirements and new standards have been introduced in industry. There are several well-established methods for defects evaluation based on various principles (both destructive and non-destructive). However, all conventional methods have various deficiencies and the information about internal voids/porosity that can be extracted is limited. Most of these drawbacks can be overcome by using X-ray computed tomography (CT). Unlike other methods, CT provides full three-dimensional information about shape, size and distribution of internal voids and porosity; however, the accuracy of measurements is still under investigation. Hence, further evaluations on CT porosity measurements must be performed in order to consider X-ray computed tomography a reliable instrument for the assessment and detection of internal defects. A reference object with artificial defects was used in this research work in order to evaluate the accuracy of porosity measurements by CT. The reference object was manufactured by ultra-precision micro milling. The object contains dismountable components with embedded internal hemispherical features that simulate internal porosity. The artificial porosity was micro-milled on top surfaces of dismountable cylindrical inserts. The hemispherical calottes were thereafter calibrated by traceable coordinate measuring systems and calibrated values were compared to actual values measured by a CT system. The accuracy of CT porosity measurements was then evaluated based on results obtained on various measurands, using different software tools and measuring procedures, comparing real scans to numerical simulations and investigating the influence of CT system parameters settings on measurement results. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:377 / 387
页数:11
相关论文
共 50 条
  • [1] Traceable Porosity Measurements in Industrial Components Using X-Ray Computed Tomography
    Hermanek, Petr
    Zanini, Filippo
    Carmignato, Simone
    JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME, 2019, 141 (05):
  • [2] Establishment of metrological traceability in porosity measurements by X-ray computed tomography
    Hermanek, Petr
    Carmignato, Simone
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XI, 2017, 10391
  • [3] Porosity Measurement Method by X-ray Computed Tomography
    Prokop, Josef
    Sveda, Libor
    Jancarek, Alexandr
    Pina, Ladislav
    FRACTOGRAPHY OF ADVANCED CERAMICS III, 2009, 409 : 402 - 405
  • [4] Porosity estimation method by X-ray computed tomography
    Taud, H
    Martinez-Angeles, R
    Parrot, JF
    Hernandez-Escobedo, L
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2005, 47 (3-4) : 209 - 217
  • [5] X-ray computed tomography instrument performance evaluation: Detecting geometry errors using a calibrated artifact
    Muralikrishnan, Bala
    Shilling, Meghan
    Phillips, Steve
    Ren, Wei
    Lee, Vincent
    Kim, Felix
    Alberts, Gabriel
    Aloisi, Valentina
    DIMENSIONAL OPTICAL METROLOGY AND INSPECTION FOR PRACTICAL APPLICATIONS VIII, 2019, 10991
  • [6] Assessment of the accuracy of dental enamel thickness measurements using microfocal X-ray computed tomography
    Olejniczak, AJ
    Grine, FE
    ANATOMICAL RECORD PART A-DISCOVERIES IN MOLECULAR CELLULAR AND EVOLUTIONARY BIOLOGY, 2006, 288A (03): : 263 - 275
  • [7] Simple and fast porosity analysis of concrete using X-ray computed tomography
    du Plessis, Anton
    Olawuyi, Babatunde James
    Boshoff, William Peter
    le Roux, Stephan Gerhard
    MATERIALS AND STRUCTURES, 2016, 49 (1-2) : 553 - 562
  • [8] Simple and fast porosity analysis of concrete using X-ray computed tomography
    Anton du Plessis
    Babatunde James Olawuyi
    William Peter Boshoff
    Stephan Gerhard le Roux
    Materials and Structures, 2016, 49 : 553 - 562
  • [9] Porosity Content Evaluation in Carbon-Fiber/Epoxy Composites Using X-ray Computed Tomography
    Yang, Peng
    Elhajjar, Rani
    POLYMER-PLASTICS TECHNOLOGY AND ENGINEERING, 2014, 53 (03) : 217 - 222
  • [10] X-ray computed tomography of the periodically moving object
    Vavrik, D.
    Fila, T.
    Koudelka, P.
    Kytyr, D.
    Machacek, M.
    Rada, V.
    Zemlicka, J.
    Zlamal, P.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (01)