Continuous glucose monitoring in interstitial fluid using glucose oxidase-based sensor compared to established blood glucose measurement in rats

被引:27
|
作者
Woderer, Stefanie
Henninger, Nadja
Garthe, Claus-Dieter
Kloetzer, Hans Martin
Hajnsek, Martin
Kamecke, Ulrike
Gretz, Norbert
Kraenzlin, Bettina
Pill, Johannes
机构
[1] Roche Diagnost GmbH, D-68305 Mannheim, Germany
[2] Heidelberg Univ, Univ Hosp Mannheim, Med Res Ctr, D-68167 Mannheim, Germany
[3] Roche Diagnost GmbH, A-8020 Graz, Austria
[4] Metecon GmbH, D-68165 Mannheim, Germany
关键词
glucose biosensor; continuous glucose monitoring; glucose oxidase; glucose in interstitial fluid; blood glucose; rat;
D O I
10.1016/j.aca.2006.08.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glucose monitoring is of importance for success of complex therapeutic interventions in diabetic patients. Its impact on treatment and glycemic control is demonstrated in large clinical trials. Up to eight blood glucose measurements per day are recommended. Notwithstanding, a substantial number of diabetic patients cannot or will not monitor their blood glucose appropriately. Considerable progress in control of disturbed metabolism in diabetic patients can be expected by continuous glucose monitoring. The aim of the study was to evaluate the performance of a new amperometric glucose oxidase-based glucose sensor in vitro and in vivo after subcutaneous implantation into rats. For in vitro testing current output of sensors was measured by exposure to increasing and decreasing glucose concentrations up to 472 mg dL(-1) over a time period of 7 days. After subcutaneous implantation of sensors into interscapular region of male rats glucose in interstitial fluid was evaluated and compared to glucose in arterial blood up to 7 days. Hyper- and hypoglycaemia were induced by intravenous application of glucose and insulin, respectively. Current of each implanted sensor was converted into glucose concentration using the first blood glucose measurement only. A change of current with glucose of 0.35 nA mg(-1) dL(-1) indicates high sensitivity of the sensor in vitro. The response time (90% of steady state) was calculated by approximately 60 s. Test strips for blood glucose measurement as reference for sensor readings was found as an appropriate and rapidly available method in rats by comparison with established hexokinase method in an automated lab analyzer with limits of agreement of +32.8 and -25.7 mg dL(-1) in Bland-Altman analysis. In normo- and hypoglycaemic range sensor readings in interstitial fluid correlated well with blood glucose measurements whereas hyperglycaemia was not reflected by the sensor completely when blood glucose was changing rapidly. The data given characterize a sensor with high sensitivity, long term stability and short response time. A single calibration of the sensor is required only in measurement periods up to 7 days. The findings demonstrate that the sensor is a highly promising candidate for assessment in humans. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [41] Interstitial fluid glucose time-lag correction for real-time continuous glucose monitoring
    Keenan, D. Barry
    Mastrototaro, John J.
    Weinzimer, Stuart A.
    Steil, Garry M.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2013, 8 (01) : 81 - 89
  • [42] CONTINUOUS BLOOD GLUCOSE MONITORING SYSTEM USING INTRAVENOUS MICRODIALYSIS AND GLUCOSE SENSING
    Schaller-Ammann, R.
    Greiner, H.
    Huber, A.
    O'Connell, M.
    Krejci, J.
    Porro, G.
    Korsatko, S.
    Gurban, J.
    Deller, S.
    Brunner, M.
    Berghofer, A.
    Priedl, J.
    Zijlstra, E.
    Heise, T.
    Pieber, T. R.
    Schaupp, L.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A72 - A72
  • [43] Clinical Accuracy of a Glucose Oxidase-Based Blood Glucose Test-Strip Across Extremes of Oxygen Partial Pressure
    Setford, Steven
    Phillips, Stuart
    Cameron, Hilary
    Grady, Mike
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (06): : 1445 - 1451
  • [44] Short Term Blood Glucose Prediction based on Continuous Glucose Monitoring Data
    Mohebbi, Ali
    Johansen, Alexander R.
    Hansen, Nicklas
    Christensen, Peter E.
    Tarp, Jens M.
    Jensen, Morten L.
    Bengtsson, Henrik
    Morup, Morten
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 5140 - 5145
  • [45] Measurement Performance of Two Continuous Tissue Glucose Monitoring Systems Intended for Replacement of Blood Glucose Monitoring
    Freckmann, Guido
    Link, Manuela
    Pleus, Stefan
    Westhoff, Antje
    Kamecke, Ulrike
    Haug, Cornelia
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (08) : 541 - 549
  • [46] Development of Silicalite/Glucose Oxidase-Based Biosensor and Its Application for Glucose Determination in Juices and Nectars
    Oleksandr Ye Dudchenko
    Viktoriya M. Pyeshkova
    Oleksandr O. Soldatkin
    Burcu Akata
    Berna O Kasap
    Alexey P. Soldatkin
    Sergei V. Dzyadevych
    Nanoscale Research Letters, 2016, 11
  • [47] Measurement of Glucose Area Under the Curve Using Minimally Invasive Interstitial Fluid Extraction Technology: Evaluation of Glucose Monitoring Concepts Without Blood Sampling
    Sato, Toshiyuki
    Okada, Seiki
    Hagino, Kei
    Asakura, Yoshihiro
    Kikkawa, Yasuo
    Kojima, Junko
    Watanabe, Toshihiro
    Maekawa, Yasunori
    Isobe, Kazuki
    Koike, Reona
    Nakajima, Hiromu
    Asano, Kaoru
    DIABETES TECHNOLOGY & THERAPEUTICS, 2011, 13 (12) : 1194 - 1200
  • [48] Continuous glucose monitoring on the ICU using a subcutaneous sensor
    Punke, M. A.
    Decker, C.
    Wodack, K.
    Reuter, D. A.
    Kluge, S.
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2015, 110 (05) : 360 - 363
  • [49] Glucose Oxidase-Based Glucose Biosensing with a Simple Dual Ag/AgCl Probe Conductivity Readout
    Loha, Kawin
    Soysa, H. Sasimali M.
    Boonkoom, Thitikorn
    Japrung, Deanpen
    Schulte, Albert
    ANALYTICAL CHEMISTRY, 2024, 96 (38) : 15097 - 15101
  • [50] Microelectronic sensor for continuous glucose monitoring
    Sanches Nascimento, Raphael Aparecido
    Mulato, Marcelo
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2019, 125 (03):