Continuous glucose monitoring in interstitial fluid using glucose oxidase-based sensor compared to established blood glucose measurement in rats

被引:27
|
作者
Woderer, Stefanie
Henninger, Nadja
Garthe, Claus-Dieter
Kloetzer, Hans Martin
Hajnsek, Martin
Kamecke, Ulrike
Gretz, Norbert
Kraenzlin, Bettina
Pill, Johannes
机构
[1] Roche Diagnost GmbH, D-68305 Mannheim, Germany
[2] Heidelberg Univ, Univ Hosp Mannheim, Med Res Ctr, D-68167 Mannheim, Germany
[3] Roche Diagnost GmbH, A-8020 Graz, Austria
[4] Metecon GmbH, D-68165 Mannheim, Germany
关键词
glucose biosensor; continuous glucose monitoring; glucose oxidase; glucose in interstitial fluid; blood glucose; rat;
D O I
10.1016/j.aca.2006.08.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glucose monitoring is of importance for success of complex therapeutic interventions in diabetic patients. Its impact on treatment and glycemic control is demonstrated in large clinical trials. Up to eight blood glucose measurements per day are recommended. Notwithstanding, a substantial number of diabetic patients cannot or will not monitor their blood glucose appropriately. Considerable progress in control of disturbed metabolism in diabetic patients can be expected by continuous glucose monitoring. The aim of the study was to evaluate the performance of a new amperometric glucose oxidase-based glucose sensor in vitro and in vivo after subcutaneous implantation into rats. For in vitro testing current output of sensors was measured by exposure to increasing and decreasing glucose concentrations up to 472 mg dL(-1) over a time period of 7 days. After subcutaneous implantation of sensors into interscapular region of male rats glucose in interstitial fluid was evaluated and compared to glucose in arterial blood up to 7 days. Hyper- and hypoglycaemia were induced by intravenous application of glucose and insulin, respectively. Current of each implanted sensor was converted into glucose concentration using the first blood glucose measurement only. A change of current with glucose of 0.35 nA mg(-1) dL(-1) indicates high sensitivity of the sensor in vitro. The response time (90% of steady state) was calculated by approximately 60 s. Test strips for blood glucose measurement as reference for sensor readings was found as an appropriate and rapidly available method in rats by comparison with established hexokinase method in an automated lab analyzer with limits of agreement of +32.8 and -25.7 mg dL(-1) in Bland-Altman analysis. In normo- and hypoglycaemic range sensor readings in interstitial fluid correlated well with blood glucose measurements whereas hyperglycaemia was not reflected by the sensor completely when blood glucose was changing rapidly. The data given characterize a sensor with high sensitivity, long term stability and short response time. A single calibration of the sensor is required only in measurement periods up to 7 days. The findings demonstrate that the sensor is a highly promising candidate for assessment in humans. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [31] Calibration of glucose oxidase-based test strips for capillary blood measurement with oxygen saturated venous blood samples
    Cheng, Wen-Jing
    Lin, Chii-Wann
    Wu, Tai-Guang
    Su, Chein-Shyong
    Hsieh, Ming-Song
    CLINICA CHIMICA ACTA, 2013, 415 : 152 - 157
  • [32] GLUCOSE OXIDASE CHEMILUMINESCENCE MEASUREMENT OF GLUCOSE IN URINE COMPARED WITH HEXOKINASE METHOD
    WILLIAMS, DC
    HUFF, GF
    SEITZ, WR
    CLINICAL CHEMISTRY, 1976, 22 (03) : 372 - 374
  • [33] Engineered PQQ glucose dehydrogenase based enzyme sensor for continuous glucose monitoring
    Okuda, J
    Wakai, J
    Igarashi, S
    Sode, K
    ANALYTICAL LETTERS, 2004, 37 (09) : 1847 - 1857
  • [34] Development of an oxidase-based glucose sensor using thickness-shear-mode quartz crystals
    Reddy, SM
    Jones, JP
    Lewis, TJ
    Vadgama, PM
    ANALYTICA CHIMICA ACTA, 1998, 363 (2-3) : 203 - 213
  • [35] BLOOD-GLUCOSE MEASUREMENT BY CAPILLARY FILTRATE COLLECTOR (CFC) AND GLUCOSE-OXIDASE SENSOR
    ASH, SR
    PEYTON, JD
    RAINIER, JB
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 115 - PMSE
  • [36] Accuracy of a seven-day continuous glucose sensor compared to YSI blood glucose values
    Zisser, Howard
    Shwartz, Sherwyn
    Ratner, Robert
    Wise, Jonathan
    Bailey, Timothy
    DIABETES, 2007, 56 : A24 - A25
  • [37] CONTINUOUS MONITORING OF BLOOD GLUCOSE
    ROSEVEAR, JW
    CLINICAL CHEMISTRY, 1971, 17 (07) : 628 - &
  • [38] Continuous monitoring of blood glucose
    Robert, JJ
    HORMONE RESEARCH, 2002, 57 : 81 - 84
  • [39] An Interstitial Fluid Transdermal Extraction Chip with Vacuum Generator and Volume Sensor for Continuous Glucose Monitoring
    Yu, Haixia
    Li, Dachao
    Ji, Yongjie
    Zhang, Xiaoli
    Xu, Kexin
    MICRO-NANO TECHNOLOGY XIV, PTS 1-4, 2013, 562-565 : 571 - 575
  • [40] Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring
    Aussedat, B
    Dupire-Angel, M
    Gifford, R
    Klein, JC
    Wilson, GS
    Reach, G
    AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2000, 278 (04): : E716 - E728