Continuous glucose monitoring on the ICU using a subcutaneous sensor

被引:0
|
作者
Punke, M. A. [1 ]
Decker, C. [2 ]
Wodack, K. [1 ]
Reuter, D. A. [1 ,2 ]
Kluge, S. [2 ]
机构
[1] Hamburg Eppendorf Univ Med Ctr, Dept Anesthesiol, Ctr Anesthesiol & Intens Care Med, D-20246 Hamburg, Germany
[2] Hamburg Eppendorf Univ Med Ctr, Dept Intens Care Med, Ctr Anesthesiol & Intens Care Med, D-20246 Hamburg, Germany
关键词
Critical ill patients; Intensive care unit; Blood gas analyzer; Continuous glucose monitoring; Hypoglycemia; INTENSIVE INSULIN THERAPY; CRITICALLY-ILL PATIENTS; HYPOGLYCEMIA; VARIABILITY; MORTALITY; HYPERGLYCEMIA;
D O I
10.1007/s00063-014-0453-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Hypoglycemia is a frequent and feared complication of insulin therapy on the intensive care unit (ICU). Sedated patients in particular are at risk for hypoglycemia due to the absence of clinical symptoms. Furthermore, recent studies point to a correlation between the variability of blood glucose and mortality. Therefore, continuous glucose monitoring has the potential to influence outcome due to a better control of blood glucose in critically ill patients. We evaluated the efficacy, accuracy and safety of a new commercially available subcutaneous continuous glucose monitoring system (sCGM; SentrinoA (R), Medtronic) in a pilot study in critically ill adult patients. sCGM data were recorded for up to 72 h and values were compared with blood glucose values measured by cassette-based blood gas analyzer (BGA). A total of 14 patients (eight male, six female), with a mean age of 62.1 +/- 9.8 years, referred to the ICU after major abdominal surgery were studied. The average simplified acute physiology score (SAPS II) was 35 +/- 9. Three patients had known type II diabetes. The average runtime of sensors was 44.1 +/- 22.1 h. In comparison to BGA, measurement of blood glucose by sCGM revealed an accuracy of 1.5 mg/dl, and a precision of + 34.2 mg/dl to -aEuro parts per thousand 31.2 mg/dl. Linn's concordance correlation coefficient yielded 0.74 with a 95 % confidence interval of 0.68-0.78. No hypoglycemic events, defined as a blood glucose level below 70 mg/dl, occurred during treatment. sCGM monitoring via a subcutaneous sensor demonstrated high accuracy and considerable variability compared to blood gas samples, even in critically ill patients.
引用
收藏
页码:360 / 363
页数:4
相关论文
共 50 条
  • [1] Continuous glucose monitoring on the ICU using a subcutaneous sensor [Kontinuierliches Glukosemonitoring auf Intensivstation mit subkutanem Sensor]
    Punke M.A.
    Decker C.
    Wodack K.
    Reuter D.A.
    Kluge S.
    Medizinische Klinik - Intensivmedizin und Notfallmedizin, 2015, 110 (5) : 360 - 363
  • [2] A MEMS SENSOR FOR CONTINUOUS MONITORING OF GLUCOSE IN SUBCUTANEOUS TISSUE
    Huang, X.
    Li, S.
    Schultz, J.
    Wang, Q.
    Lin, Q.
    IEEE 22ND INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2009), 2009, : 352 - 355
  • [3] Evaluation of conventional blood glucose monitoring as an indicator of integrated glucose values using a continuous subcutaneous sensor
    Zavalkoff, SR
    Polychronakos, C
    DIABETES CARE, 2002, 25 (09) : 1603 - 1606
  • [4] SUBCUTANEOUS CONTINUOUS GLUCOSE MONITORING: A COMPARISON
    Albuquerque, Andrea
    NURSING IN CRITICAL CARE, 2021, 26 : 29 - 29
  • [5] Subcutaneous a continuous glucose monitoring - Feasibility of a new microdialysis-based glucose sensor system
    Jungheim, K
    Wientjes, KJ
    Heinemann, L
    Lodwig, V
    Koschinsky, T
    Koschinsky, T
    Schoonen, AJ
    DIABETES CARE, 2001, 24 (09) : 1696 - 1697
  • [6] Subcutaneous continuous glucose monitoring: Feasibility of a new microdialysis based sensor system
    Jungheim, K
    Wientjes, KJ
    Lodwig, V
    Koschinsky, T
    Schoonen, AJ
    DIABETES, 2001, 50 : A3 - A3
  • [7] Towards continuous glucose monitoring in the ICU
    Ruiz-Santana, S.
    Saavedra, P.
    MEDICINA INTENSIVA, 2015, 39 (07) : 393 - 394
  • [8] Miniaturized fiber-optic hybrid sensor for continuous glucose monitoring in subcutaneous tissue
    Pasic, Alen
    Koehler, Hans
    Klimant, Ingo
    Schaupp, Lukas
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01) : 60 - 68
  • [9] Continuous subcutaneous glucose monitoring:: The GlucoDay® system
    Maran, A
    Poscia, A
    DIABETES NUTRITION & METABOLISM, 2002, 15 (06) : 429 - 433
  • [10] Continuous monitoring of blood glucose using a fiberoptic-based intravascular sensor during postoperative care in the ICU
    M Prasad
    P Gopal
    G Mannam
    Critical Care, 18 (Suppl 1):