Continuous glucose monitoring on the ICU using a subcutaneous sensor

被引:0
|
作者
Punke, M. A. [1 ]
Decker, C. [2 ]
Wodack, K. [1 ]
Reuter, D. A. [1 ,2 ]
Kluge, S. [2 ]
机构
[1] Hamburg Eppendorf Univ Med Ctr, Dept Anesthesiol, Ctr Anesthesiol & Intens Care Med, D-20246 Hamburg, Germany
[2] Hamburg Eppendorf Univ Med Ctr, Dept Intens Care Med, Ctr Anesthesiol & Intens Care Med, D-20246 Hamburg, Germany
关键词
Critical ill patients; Intensive care unit; Blood gas analyzer; Continuous glucose monitoring; Hypoglycemia; INTENSIVE INSULIN THERAPY; CRITICALLY-ILL PATIENTS; HYPOGLYCEMIA; VARIABILITY; MORTALITY; HYPERGLYCEMIA;
D O I
10.1007/s00063-014-0453-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Hypoglycemia is a frequent and feared complication of insulin therapy on the intensive care unit (ICU). Sedated patients in particular are at risk for hypoglycemia due to the absence of clinical symptoms. Furthermore, recent studies point to a correlation between the variability of blood glucose and mortality. Therefore, continuous glucose monitoring has the potential to influence outcome due to a better control of blood glucose in critically ill patients. We evaluated the efficacy, accuracy and safety of a new commercially available subcutaneous continuous glucose monitoring system (sCGM; SentrinoA (R), Medtronic) in a pilot study in critically ill adult patients. sCGM data were recorded for up to 72 h and values were compared with blood glucose values measured by cassette-based blood gas analyzer (BGA). A total of 14 patients (eight male, six female), with a mean age of 62.1 +/- 9.8 years, referred to the ICU after major abdominal surgery were studied. The average simplified acute physiology score (SAPS II) was 35 +/- 9. Three patients had known type II diabetes. The average runtime of sensors was 44.1 +/- 22.1 h. In comparison to BGA, measurement of blood glucose by sCGM revealed an accuracy of 1.5 mg/dl, and a precision of + 34.2 mg/dl to -aEuro parts per thousand 31.2 mg/dl. Linn's concordance correlation coefficient yielded 0.74 with a 95 % confidence interval of 0.68-0.78. No hypoglycemic events, defined as a blood glucose level below 70 mg/dl, occurred during treatment. sCGM monitoring via a subcutaneous sensor demonstrated high accuracy and considerable variability compared to blood gas samples, even in critically ill patients.
引用
收藏
页码:360 / 363
页数:4
相关论文
共 50 条
  • [21] Role of continuous subcutaneous glucose monitoring in intensive care
    Marics, Gabor
    Koncz, Levente
    Korner, Anna
    Mikos, Borbala
    Toth-Heyn, Peter
    ORVOSI HETILAP, 2013, 154 (27) : 1043 - 1048
  • [22] Subcutaneous continuous glucose monitoring in severe burn patients
    Klonoff, David C.
    CRITICAL CARE MEDICINE, 2007, 35 (05) : 1445 - 1445
  • [24] Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring
    Aussedat, B
    Dupire-Angel, M
    Gifford, R
    Klein, JC
    Wilson, GS
    Reach, G
    AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2000, 278 (04): : E716 - E728
  • [25] Continuous glucose monitoring in the ICU: clinical considerations and consensus
    Krinsley, James S.
    Chase, J. Geoffrey
    Gunst, Jan
    Martensson, Johan
    Schultz, Marcus J.
    Taccone, Fabio S.
    Wernerman, Jan
    Bohe, Julien
    De Block, Christophe
    Desaive, Thomas
    Kalfon, Pierre
    Preiser, Jean-Charles
    CRITICAL CARE, 2017, 21
  • [26] Real-time continuous glucose monitoring in the ICU
    J Gios
    B Manuel-y-Keenoy
    P Rogiers
    Critical Care, 19 (Suppl 1):
  • [27] Continuous glucose monitoring in the ICU: clinical considerations and consensus
    James S. Krinsley
    J. Geoffrey Chase
    Jan Gunst
    Johan Martensson
    Marcus J. Schultz
    Fabio S. Taccone
    Jan Wernerman
    Julien Bohe
    Christophe De Block
    Thomas Desaive
    Pierre Kalfon
    Jean-Charles Preiser
    Critical Care, 21
  • [28] Continuous glucose monitoring versus conventional glucose monitoring in the ICU: A randomized controlled trial
    Chu, Chen
    Li, Jian
    Yang, XiaoDong
    Zhao, HuiJing
    Wu, ZaiXian
    Xu, RuoXin
    Gao, JianLing
    JOURNAL OF CRITICAL CARE, 2024, 84
  • [29] TOWARDS CONTINUOUS GLUCOSE MONITORING - INVIVO EVALUATION OF A MINIATURIZED GLUCOSE SENSOR IMPLANTED FOR SEVERAL DAYS IN RAT SUBCUTANEOUS TISSUE
    MOATTISIRAT, D
    CAPRON, E
    POITOUT, V
    REACH, G
    BINDRA, DS
    ZHANG, Y
    WILSON, GS
    THEVENOT, DR
    DIABETOLOGIA, 1992, 35 (03) : 224 - 230
  • [30] Use of Continuous Glucose Monitoring to Achieve Target Glucose Levels in the ICU
    Steil, Garry M.
    Alexander, Jamin
    Ortiz-Rubio, Paulina
    Soto-Rivera, Carmen L.
    Nadkarni, Vinay
    Agus, Michael
    DIABETES, 2015, 64 : A47 - A47