Continuous glucose monitoring on the ICU using a subcutaneous sensor

被引:0
|
作者
Punke, M. A. [1 ]
Decker, C. [2 ]
Wodack, K. [1 ]
Reuter, D. A. [1 ,2 ]
Kluge, S. [2 ]
机构
[1] Hamburg Eppendorf Univ Med Ctr, Dept Anesthesiol, Ctr Anesthesiol & Intens Care Med, D-20246 Hamburg, Germany
[2] Hamburg Eppendorf Univ Med Ctr, Dept Intens Care Med, Ctr Anesthesiol & Intens Care Med, D-20246 Hamburg, Germany
关键词
Critical ill patients; Intensive care unit; Blood gas analyzer; Continuous glucose monitoring; Hypoglycemia; INTENSIVE INSULIN THERAPY; CRITICALLY-ILL PATIENTS; HYPOGLYCEMIA; VARIABILITY; MORTALITY; HYPERGLYCEMIA;
D O I
10.1007/s00063-014-0453-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Hypoglycemia is a frequent and feared complication of insulin therapy on the intensive care unit (ICU). Sedated patients in particular are at risk for hypoglycemia due to the absence of clinical symptoms. Furthermore, recent studies point to a correlation between the variability of blood glucose and mortality. Therefore, continuous glucose monitoring has the potential to influence outcome due to a better control of blood glucose in critically ill patients. We evaluated the efficacy, accuracy and safety of a new commercially available subcutaneous continuous glucose monitoring system (sCGM; SentrinoA (R), Medtronic) in a pilot study in critically ill adult patients. sCGM data were recorded for up to 72 h and values were compared with blood glucose values measured by cassette-based blood gas analyzer (BGA). A total of 14 patients (eight male, six female), with a mean age of 62.1 +/- 9.8 years, referred to the ICU after major abdominal surgery were studied. The average simplified acute physiology score (SAPS II) was 35 +/- 9. Three patients had known type II diabetes. The average runtime of sensors was 44.1 +/- 22.1 h. In comparison to BGA, measurement of blood glucose by sCGM revealed an accuracy of 1.5 mg/dl, and a precision of + 34.2 mg/dl to -aEuro parts per thousand 31.2 mg/dl. Linn's concordance correlation coefficient yielded 0.74 with a 95 % confidence interval of 0.68-0.78. No hypoglycemic events, defined as a blood glucose level below 70 mg/dl, occurred during treatment. sCGM monitoring via a subcutaneous sensor demonstrated high accuracy and considerable variability compared to blood gas samples, even in critically ill patients.
引用
收藏
页码:360 / 363
页数:4
相关论文
共 50 条
  • [11] Feasibility of Continuous Ketone Monitoring in Subcutaneous Tissue Using a Ketone Sensor
    Alva, Shridhara
    Castorino, Kristin
    Cho, Hyun
    Ou, Junli
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (04): : 768 - 774
  • [12] A glucose sensor protein for continuous glucose monitoring
    Veetil, Jithesh V.
    Jin, Sha
    Ye, Kaiming
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (04): : 1650 - 1655
  • [13] CONTINUOUS GLUCOSE MONITORING IN THE ICU: THE EFFECT OF A COMMONLY ADMINISTERED MEDICATION ON A NOVEL SENSOR MEMBRANE
    Ramachandran, M.
    Luo, Y.
    Chiu, C.
    Rose, J.
    Gottlieb, R.
    INTENSIVE CARE MEDICINE, 2010, 36 : S151 - S151
  • [14] Miniaturization of an Osmotic Pressure-Based Glucose Sensor for Continuous Intraperitoneal and Subcutaneous Glucose Monitoring by Means of Nanotechnology
    Pfuetzner, Andreas
    Tencer, Barbora
    Stamm, Boris
    Mehta, Mandar
    Sharma, Preeti
    Gilyazev, Rustam
    Jensch, Hendrick
    Thome, Nicole
    Huth, Michael
    SENSORS, 2023, 23 (09)
  • [15] Microelectronic sensor for continuous glucose monitoring
    Sanches Nascimento, Raphael Aparecido
    Mulato, Marcelo
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2019, 125 (03):
  • [16] Impaction of a continuous glucose monitoring sensor
    Park, Kyong Chan
    Choi, Hwan Jun
    ARCHIVES OF PLASTIC SURGERY-APS, 2021, 48 (04): : 392 - 394
  • [17] Microelectronic sensor for continuous glucose monitoring
    Raphael Aparecido Sanches Nascimento
    Marcelo Mulato
    Applied Physics A, 2019, 125
  • [18] GLUCOSE CONTROL IN THE ICU USING CONTINUOUS GLUCOSE MONITORING: WHAT LEVEL OF MEASUREMENT ERROR IS ACCEPTABLE?
    Wilinska, M. E.
    Hovorka, R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 : A3 - A3
  • [19] Accuracy and reliability of continuous glucose monitoring at the ICU; a head to head comparison of two subcutaneous glucose sensors in cardiac surgery patients
    Siegelaar, S. E.
    Barwari, T.
    Hermanides, J.
    Stooker, W.
    van der Voort, P. H. J.
    DeVries, J. H.
    DIABETOLOGIA, 2010, 53 : S102 - S102
  • [20] Glucose prediction from continuous subcutaneous monitoring data
    Maran, A
    Sparacino, G
    Pavanini, A
    Crepaldi, C
    Poscia, A
    Tiengo, A
    Avogaro, A
    Cobelli, C
    DIABETES, 2004, 53 : A105 - A105