Calculating bone-lead measurement variance

被引:30
|
作者
Todd, AC [1 ]
机构
[1] Mt Sinai Sch Med, Dept Community & Prevent Med, New York, NY 10029 USA
关键词
D O I
10.2307/3454376
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The technique of Cd-109-based X-ray fluorescence (XRF) measurements of lead in bone is well established. A paper by some XRF researchers [Gordon CL, et al. The Reproducibility of Cd-109-based X-ray Fluorescence Measurements of Bone Lead. Environ Health Perspect 102:690-694 (1994)] presented the currently practiced method for calculating the variance of an in vivo measurement once a calibration line has been established. This paper corrects typographical errors in the method published by those authors; presents a crude estimate of the measurement error that can be acquired without computational peak fitting programs; and draws attention to the measurement error attributable to covariance, an important feature in the construct of the currently accepted method that is flawed under certain circumstances.
引用
收藏
页码:383 / 386
页数:4
相关论文
共 50 条
  • [2] Contamination of in vivo bone-lead measurements
    Todd, AC
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (01): : 229 - 240
  • [3] Influence of bone-lead stores on the observed effectiveness of lead hazard intervention
    Rust, SW
    Kumar, P
    Burgoon, DA
    Niemuth, NA
    Schultz, BD
    ENVIRONMENTAL RESEARCH, 1999, 81 (03) : 175 - 184
  • [4] Coherent scattering and matrix correction in bone-lead measurements
    Todd, AC
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (07): : 1953 - 1963
  • [5] Decrease in birth weight in relation to maternal bone-lead burden
    GonzalezCossio, T
    Peterson, KE
    Sanin, LH
    Fishbein, E
    Palazuelos, E
    Aro, A
    HernandezAvila, M
    Hu, H
    PEDIATRICS, 1997, 100 (05) : 856 - 862
  • [6] BONE-LEAD ANALYSIS - DEVELOPMENT OF ANALYTICAL METHODOLOGY FOR MILLIGRAM SAMPLES
    SUBRAMANIAN, KS
    CONNOR, JW
    MERANGER, JC
    ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1993, 24 (04) : 494 - 497
  • [7] THE INFLUENCE OF BONE-DENSITY ON IN VIVO K X-RAY FLUORESCENCE BONE-LEAD MEASUREMENTS
    Lodwick, Camille J.
    Lodwick, Jeffrey C.
    Spitz, Henry B.
    HEALTH PHYSICS, 2011, 100 (05): : 502 - 507
  • [8] An investigation of the 109Cd γ-ray induced K-x-ray fluorescence (XRF) bone-lead measurement calibration procedure
    Nie, HL
    Chettle, DR
    McNeill, FE
    O'Meara, JM
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (19): : N325 - N334
  • [9] Bone lead measurement
    Payne, Mark
    Egden, Lesley
    Behinaein, Sepideh
    Chettle, David
    McNeill, Fiona
    Webber, Colin
    CANADIAN FAMILY PHYSICIAN, 2010, 56 (11) : 1110 - 1112
  • [10] BONE-LEAD ANALYSIS - DEVELOPMENT OF ANALYTICAL METHODOLOGY FOR MILLIGRAM SAMPLES (VOL 24, PG 494, 1993)
    SUBRAMANIAN, KS
    CONNOR, JW
    MERANGER, JC
    ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1993, 25 (03) : 411 - 411