Calculating bone-lead measurement variance

被引:30
|
作者
Todd, AC [1 ]
机构
[1] Mt Sinai Sch Med, Dept Community & Prevent Med, New York, NY 10029 USA
关键词
D O I
10.2307/3454376
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The technique of Cd-109-based X-ray fluorescence (XRF) measurements of lead in bone is well established. A paper by some XRF researchers [Gordon CL, et al. The Reproducibility of Cd-109-based X-ray Fluorescence Measurements of Bone Lead. Environ Health Perspect 102:690-694 (1994)] presented the currently practiced method for calculating the variance of an in vivo measurement once a calibration line has been established. This paper corrects typographical errors in the method published by those authors; presents a crude estimate of the measurement error that can be acquired without computational peak fitting programs; and draws attention to the measurement error attributable to covariance, an important feature in the construct of the currently accepted method that is flawed under certain circumstances.
引用
收藏
页码:383 / 386
页数:4
相关论文
共 50 条
  • [11] Bone lead measurement Response
    Abelsohn, Alan R.
    Sanborn, Margaret
    CANADIAN FAMILY PHYSICIAN, 2010, 56 (11) : 1112 - 1112
  • [12] CALCULATING THE ESTIMATE OF VARIANCE
    CHETRICK, T
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1981, 38 (02): : 166 - &
  • [13] An agreed statement on calculating lead concentration and uncertainity in XRF in vivo bone lead analysis
    Chettle, DR
    Arnold, ML
    Aro, ACA
    Fleming, DEB
    Kondrashov, VS
    McNeill, FE
    Moshier, EL
    Nie, H
    Rothenberg, SJ
    Stronach, IM
    APPLIED RADIATION AND ISOTOPES, 2003, 58 (05) : 603 - 605
  • [14] Calculating the uncertainty in lead concentration for in vivo bone lead X-ray fluorescence
    Todd, AC
    Chettle, DR
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (13): : 2033 - 2039
  • [15] CALCULATING POWER IN ANALYSIS OF VARIANCE
    KOELE, P
    PSYCHOLOGICAL BULLETIN, 1982, 92 (02) : 513 - 516
  • [16] DIRECT MEASUREMENT OF LEAD IN BONE - A PROMISING BIOMARKER
    LANDRIGAN, PJ
    TODD, AC
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 271 (03): : 239 - 240
  • [17] INVIVO TIBIAL XFR MEASUREMENT OF BONE LEAD
    WEDEEN, RD
    ARCHIVES OF ENVIRONMENTAL HEALTH, 1990, 45 (02): : 69 - 71
  • [18] In vivo bone lead measurement in suburban teenagers
    Hoppin, JA
    Aro, A
    Hu, H
    Ryan, PB
    PEDIATRICS, 1997, 100 (03) : 365 - 370
  • [19] Measurement variability associated with KXRF bone lead measurement in young adults
    Hoppin, JA
    Aro, A
    Hu, H
    Ryan, PB
    ENVIRONMENTAL HEALTH PERSPECTIVES, 2000, 108 (03) : 239 - 242
  • [20] CALCULATING THE VARIANCE OF SEASONALLY ADJUSTED SERIES
    BURRIDGE, P
    WALLIS, KF
    JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1985, 80 (391) : 541 - 552