Calculating bone-lead measurement variance

被引:30
|
作者
Todd, AC [1 ]
机构
[1] Mt Sinai Sch Med, Dept Community & Prevent Med, New York, NY 10029 USA
关键词
D O I
10.2307/3454376
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The technique of Cd-109-based X-ray fluorescence (XRF) measurements of lead in bone is well established. A paper by some XRF researchers [Gordon CL, et al. The Reproducibility of Cd-109-based X-ray Fluorescence Measurements of Bone Lead. Environ Health Perspect 102:690-694 (1994)] presented the currently practiced method for calculating the variance of an in vivo measurement once a calibration line has been established. This paper corrects typographical errors in the method published by those authors; presents a crude estimate of the measurement error that can be acquired without computational peak fitting programs; and draws attention to the measurement error attributable to covariance, an important feature in the construct of the currently accepted method that is flawed under certain circumstances.
引用
收藏
页码:383 / 386
页数:4
相关论文
共 50 条
  • [21] CALCULATING THE VARIANCE OF ERRORS IN POPULATION FORECASTING
    JOCKEL, KH
    PFLAUMER, P
    STATISTICS & PROBABILITY LETTERS, 1984, 2 (04) : 211 - 213
  • [22] ALGORITHM FOR CALCULATING THE VARIANCE FUNCTION.
    Raskin, V.G.
    Yanovskiy, L.P.
    Soviet journal of automation and information sciences, 1986, 19 (02): : 96 - 98
  • [23] Calculating Sample Variance for the Combined Data
    Shin, Mi-Young
    Cho, Tae-Kyoung
    KOREAN JOURNAL OF APPLIED STATISTICS, 2008, 21 (01) : 177 - 182
  • [24] Design of an XRF system for in vivo measurement of lead in bone
    Niemela, A
    Grodzins, L
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 65 - 69
  • [25] Development of candidate reference materials for the measurement of lead in bone
    Katherine M. Hetter
    David J. Bellis
    Ciaran Geraghty
    Andrew C. Todd
    Patrick J. Parsons
    Analytical and Bioanalytical Chemistry, 2008, 391
  • [26] Development of candidate reference materials for the measurement of lead in bone
    Hetter, Katherine M.
    Bellis, David J.
    Geraghty, Ciaran
    Todd, Andrew C.
    Parsons, Patrick J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (06) : 2011 - 2021
  • [27] A study of MDL improvement for the in vivo measurement of lead in bone
    Nie, HL
    Chettle, D
    Stronach, I
    Arnold, M
    Huang, SB
    McNeill, F
    O'Meara, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 579 - 583
  • [28] New approach to calculating project cost variance
    Wang, Ching-Hwang
    Huang, Yu-Chun
    International Journal of Project Management, 2000, 18 (02) : 131 - 138
  • [29] Calculating response specificity:: Correlations or variance components?
    Hinz, A
    Hüber, B
    Schreinicke, G
    Seibt, R
    JOURNAL OF PSYCHOPHYSIOLOGY, 2000, 14 (01) : 60 - 61
  • [30] Performance appraisals of digital spectroscopy systems for the measurement of bone lead
    Bateman, SN
    Pejovic-Milic, A
    Stronach, IM
    McNeill, FE
    Chettle, DR
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (4-5) : 647 - 650