Evaluation of silicon photomultipliers: A promising new detector for MR compatible PET

被引:50
|
作者
McElroy, David P.
Saveliev, Valeri
Reznik, Alla
Rowlands, John A.
机构
[1] Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[2] DESY, D-22607 Hamburg, Germany
关键词
PET; SiPM; MRI; scintillation detectors; molecular imaging;
D O I
10.1016/j.nima.2006.10.040
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Silicon Photomultiplier (SiPM) is a compact detector which shows great promise for use in MR compatible PET systems. SiPMs are insensitive to magnetic fields, have a high intrinsic gain (about 106) and operate at low voltages (40 V), eliminating the need for sophisticated shielding and low noise preamplifiers. A prototype 1 x 1 mm(2) detector currently under investigation at the University of Toronto consists of an array of 556 independent microcells operating in Geiger mode. Each microcell thus produces a pulse of constant amplitude with the detection of one or more electrons. All microcells are connected in parallel through integrated quenching resistors, and thus the output of the SiPM is the sum of the individual standardized signals and is proportional to energy provided the number of detected light photons is less than the number of microcells. The detector was operated without a preamplifier, and using a 2 x 2 x 6 mm(2) LSO crystal and Na-22 source, the energy resolution was measured to be 25.6 +/- 0.4% FWHM and timing resolution for a detector pair was 1.9 +/- 0.1 ns FWHM. LED measurements and measurements using Ba-133 (356 kev) and (CS)-C-137 (662kev) verify that the detector is operating linearly at 511 keV. The major noise contribution is the dark current, which at -44 V results in a peak dark count rate of about 16 kHz that reduces to negligible levels above a 90 kev lower energy threshold. In the next generation of compact multi-element SiPM detectors with improved optical coupling the energy resolution should improve to below 15% FWHM, making them well suited for use in a high performance MR compatible depth of interaction PET scanner. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:106 / 109
页数:4
相关论文
共 50 条
  • [1] Evaluation of Performance and Stability of an MR Compatible PET Detector
    Shams, Ehsan
    Thiessen, Jonathan D.
    Bishop, Daryl
    Kozlowski, Piotr
    Retiere, Fabrice
    Khan, Muhammad Salman
    Sossi, Vesna
    Stortz, Greg
    Thompson, Christopher J.
    Goertzen, Andrew L.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [2] A new detector concept for silicon photomultipliers
    Sadigov, A.
    Ahmadov, F.
    Ahmadov, G.
    Ariffin, A.
    Khorev, S.
    Sadygov, Z.
    Suleymanov, S.
    Zerrouk, F.
    Madatov, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 135 - 136
  • [3] Evaluation of a MR-compatible CZT detector
    Despres, Philippe
    Izaguirre, Enrique W.
    Liu, Siyuan
    Cirignano, Leonard J.
    Kim, Hadong
    Wendland, Michael F.
    Shah, Kanai S.
    Hasegawa, Bruce H.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4324 - +
  • [4] A 4D-PET block detector based on Silicon Photomultipliers
    Marcatili, Sara
    Belcari, Nicola
    Bisogni, Maria G.
    Collazuol, Gianmaria
    Pedreschi, Elena
    Spinella, Franco
    Corsi, Francesco
    Foresta, Maurizio
    Marzocca, Cristoforo
    Matarrese, Gianvito
    Sportelli, Giancarlo
    Guerra, Pedro
    Santos, Andres
    Del Guerra, Alberto
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1949 - 1953
  • [5] Design and performance evaluation of a compact, large-area PET detector module based on silicon photomultipliers
    Wang, Yingjie
    Zhang, Zhiming
    Li, Daowu
    Wang, Baoyi
    Shuai, Lei
    Feng, Baotong
    Chai, Pei
    Liu, Shuangquan
    Tang, Haohui
    Li, Ting
    Liao, Yanfei
    Huang, Xianchao
    Chen, Yan
    Liu, Yantao
    Zhang, Yiwen
    Wei, Long
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 670 : 49 - 54
  • [6] Temperature Dependence of a SiPM Detector for an MR Compatible PET System
    Goertzen, A. L.
    Zhang, X.
    Liu, C-Y
    Kozlowski, P.
    Retiere, F.
    Ryner, L.
    Sossi, V.
    Stortz, G.
    Thompson, C. J.
    MEDICAL PHYSICS, 2012, 39 (07) : 4640 - 4640
  • [7] PET Performance Evaluation of an MR-Compatible PET Insert
    Wu, Yibao
    Catana, Ciprian
    Farrell, Richard
    Dokhale, Purushottam A.
    Shah, Kanai S.
    Qi, Jinyi
    Cherry, Simon R.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 574 - 580
  • [8] A detector head design for small-animal PET with silicon photomultipliers (SiPM)
    Moehrs, S
    Del Guerra, A
    Herbert, DJ
    Mandelkern, MA
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (05): : 1113 - 1127
  • [9] Performance evaluation of neuro-PET using silicon photomultipliers
    Jung, Jiwoong
    Choi, Yong
    Jung, Jin Ho
    Kim, Sangsu
    Im, Ki Chun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 819 : 182 - 187
  • [10] Evaluation of HPK and FBK Silicon Photomultipliers for TOF and PET Applications
    Ambrosi, G.
    Azzarello, P.
    Battiston, R.
    Ionica, M.
    Pignatel, G. U.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1566 - 1571