Evaluation of silicon photomultipliers: A promising new detector for MR compatible PET

被引:50
|
作者
McElroy, David P.
Saveliev, Valeri
Reznik, Alla
Rowlands, John A.
机构
[1] Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[2] DESY, D-22607 Hamburg, Germany
关键词
PET; SiPM; MRI; scintillation detectors; molecular imaging;
D O I
10.1016/j.nima.2006.10.040
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Silicon Photomultiplier (SiPM) is a compact detector which shows great promise for use in MR compatible PET systems. SiPMs are insensitive to magnetic fields, have a high intrinsic gain (about 106) and operate at low voltages (40 V), eliminating the need for sophisticated shielding and low noise preamplifiers. A prototype 1 x 1 mm(2) detector currently under investigation at the University of Toronto consists of an array of 556 independent microcells operating in Geiger mode. Each microcell thus produces a pulse of constant amplitude with the detection of one or more electrons. All microcells are connected in parallel through integrated quenching resistors, and thus the output of the SiPM is the sum of the individual standardized signals and is proportional to energy provided the number of detected light photons is less than the number of microcells. The detector was operated without a preamplifier, and using a 2 x 2 x 6 mm(2) LSO crystal and Na-22 source, the energy resolution was measured to be 25.6 +/- 0.4% FWHM and timing resolution for a detector pair was 1.9 +/- 0.1 ns FWHM. LED measurements and measurements using Ba-133 (356 kev) and (CS)-C-137 (662kev) verify that the detector is operating linearly at 511 keV. The major noise contribution is the dark current, which at -44 V results in a peak dark count rate of about 16 kHz that reduces to negligible levels above a 90 kev lower energy threshold. In the next generation of compact multi-element SiPM detectors with improved optical coupling the energy resolution should improve to below 15% FWHM, making them well suited for use in a high performance MR compatible depth of interaction PET scanner. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:106 / 109
页数:4
相关论文
共 50 条
  • [21] SILICON PHOTOMULTIPLIERS IN PET AND HADRONTHERAPY APPLICATIONS
    Llosa, G.
    Barrio, J.
    Bisogni, M. G.
    Cabello, J.
    Del Guerra, A.
    Gillam, J.
    Lacasta, C.
    Oliver, J.
    Rafecas, M.
    Solaz, C.
    Stankova, V.
    Torres-Espallardo, I.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S111 - S112
  • [22] Correction to: Performance Evaluation of a Newly Developed MR-Compatible Mobile PET Scanner with Two Detector Layouts
    Masao Watanabe
    Yuji Nakamoto
    Ryusuke Nakamoto
    Takayoshi Ishimori
    Tsuneo Saga
    Kaori Togashi
    Molecular Imaging and Biology, 2020, 22 : 416 - 416
  • [23] A block detector for a multislice, depth-of-interaction MR-compatible PET
    Yamamoto, S
    Takamatsu, S
    Murayama, H
    Minato, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 33 - 37
  • [24] Novel Silicon Photomultipliers for PET Application
    Llosa, Gabriela
    Battiston, Roberto
    Bisogni, Maria Giuseppina
    Boscardin, Maurizio
    Collazuol, Gianmaria
    Corsi, Francesco
    Dalla Betta, Gian-Franco
    Del Guerra, Alberto
    Dinu, Nicoleta
    Levi, Giuseppe
    Marcatili, Sara
    Moehrs, Sascha
    Marzocca, Cristoforo
    Piemonte, Claudio
    Pozza, Alberto
    Sbarra, Cristina
    Quadrani, Lucio
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1875 - 1879
  • [25] Hybrid RCD-WTA Multiplexer for MR-compatible PET Detector
    Yang, Jingyu
    Lee, Minho
    Kang, Jihoon
    JOURNAL OF MAGNETICS, 2020, 25 (04) : 626 - 631
  • [26] Small-Animal and Endoscopic PET Detector Modules Based on Multichannel Digital Silicon Photomultipliers
    Venialgo, E.
    Sinha, S.
    Gong, T.
    Mandai, S.
    Carimatto, A.
    Brunner, S. E.
    Schaart, D. R.
    Charbon, E.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [27] The silicon photomultipliers in the detector subsystems of the GlueX experiment
    Somov, A.
    Barbosa, F.
    Tolstukhin, I.
    Somov, S. V.
    Berdnikov, V. V.
    INTERNATIONAL CONFERENCE ON PARTICLE PHYSICS AND ASTROPHYSICS, 2017, 798
  • [28] Feasibility of PET detector readout by high-density Silicon Photomultipliers with epitaxial quenching resistors
    Liang, K.
    Li, B.
    Dai, L.
    Liu, H.
    Yang, R.
    Han, D.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [29] Development of a large area, high resolution, MR-compatible PET detector module
    Raylman, Raymond
    Majewski, Stan
    Stolin, Alexander
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [30] Development of a SiPM Based MR-Compatible DOI-TOF-PET Detector
    Furumiya, Tetsuo
    Tsuda, Tomoaki
    Tonami, Hiromichi
    Satoh, Masanobu
    Nakazawa, Masayuki
    Ohi, Junichi
    Kitamura, Keishi
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,