A 4D-PET block detector based on Silicon Photomultipliers

被引:0
|
作者
Marcatili, Sara [1 ]
Belcari, Nicola [1 ]
Bisogni, Maria G. [1 ]
Collazuol, Gianmaria [2 ]
Pedreschi, Elena [2 ]
Spinella, Franco [2 ]
Corsi, Francesco [3 ]
Foresta, Maurizio [3 ]
Marzocca, Cristoforo [3 ]
Matarrese, Gianvito [3 ]
Sportelli, Giancarlo
Guerra, Pedro [4 ]
Santos, Andres [5 ]
Del Guerra, Alberto [1 ,5 ]
机构
[1] Univ Pisa, I-56127 Pisa, Italy
[2] Univ Pisa, Ist Nazl Fis Nucl, I-56127 Pisa, Italy
[3] Politecnh Bari, Ist Nazl Fis Nucl, I-70100 Bari, Italy
[4] CIBER BBN, EEI Modulo, E-50018 Zaragoza, Spain
[5] Univ Politecn Madrid, E-28040 Madrid, Spain
关键词
TIMING RESOLUTION; MATRICES; ENERGY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Next generation PET scanners should fulfill very high requirements in terms of spatial, energy and timing resolution. Modern scanner performances are inherently limited by the use of standard photomultiplier tubes. The use of Silicon Photomultiplier (SiPM) matrices is proposed for the construction of a 4D PET module based on LYSO continuos crystals, which is envisaged to replace the standard PET block detector. The module will provide a submillimetric spatial resolution on the photon hit position, performing at the same time, the Depth Of Interaction (DOI) calculation and the Time Of Flight (TOF) measurement. The use of large area multi-pixel Silicon Photomultiplier (SiPM) detectors requires the development of a multichannel Digital Acquisition system (DAQ) as well as of a dedicated front-end in order not to degrade the intrinsic detector capabilities. At the University of Pisa and INFN Pisa we have developed a flexible and modular DAQ system for the read-out of 2 module in time coincidence for Positron Emission Tomography (PET) applications. Here we describe the acquisition system architecture and its characterization measurements.
引用
收藏
页码:1949 / 1953
页数:5
相关论文
共 50 条
  • [1] An innovative detector concept for hybrid 4D-PET/MRI imaging
    Cerello, P.
    Pennazio, F.
    Bisogni, M. G.
    Marino, N.
    Marzocca, C.
    Peroni, C.
    Wheadon, R.
    Del Guerra, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 : 6 - 9
  • [2] Effects of geometric asymmetries in circular photomultipliers in PET block detector
    Uribe, J
    Wong, WH
    Hu, G
    Hicks, K
    Lu, W
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 1025 - 1025
  • [3] Utility of 4D-PET/CT for ITV Definition
    Bergamo, A.
    Sandhu, A.
    Rahn, D.
    Song, W.
    MEDICAL PHYSICS, 2012, 39 (06) : 3923 - 3923
  • [4] Evaluation of silicon photomultipliers: A promising new detector for MR compatible PET
    McElroy, David P.
    Saveliev, Valeri
    Reznik, Alla
    Rowlands, John A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 106 - 109
  • [5] Small-Animal and Endoscopic PET Detector Modules Based on Multichannel Digital Silicon Photomultipliers
    Venialgo, E.
    Sinha, S.
    Gong, T.
    Mandai, S.
    Carimatto, A.
    Brunner, S. E.
    Schaart, D. R.
    Charbon, E.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [6] PET detector block with accurate 4D capabilities
    Lamprou, Efthymios
    Aguilar, Albert
    Gonzalez-Montoro, Andrea
    Monzo, Jose M.
    Canizares, Gabriel
    Iranzo, Sofia
    Vidal, Luis F.
    Hernandez, Liczandro
    Conde, Pablo
    Sanchez, Sebastian
    Sanchez, Filomeno
    Gonzalez, Antonio J.
    Benlloch, Jose M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 912 : 132 - 136
  • [7] Amplitude-Based 4D-PET/MRI for Target Motion Characterization
    Patrick, J.
    Thiessen, J.
    Capaldi, D.
    Thompson, R.
    Stodilka, R.
    Drangova, M.
    Gaede, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 3080 - 3081
  • [8] A New Methodology for Reconstruction of 4D-PET Images
    Zhong, H.
    Li, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E193 - E193
  • [9] Effect of the rotational orientation of circular photomultipliers in a PET camera block detector design
    Uribe, J
    Wong, WH
    Hu, GJ
    Hicks, K
    Wang, JM
    Baghaei, H
    Zhang, N
    Li, HD
    Yokoyama, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 1266 - 1270
  • [10] First Results of the 4D-PET Brain System
    Gonzalez-Montoro, Andrea
    Jimenez-Serrano, Santiago
    Alamo, Jorge
    Barbera, Julio
    Lucero, Alejandro
    Cucarella, Neus
    Diaz, Karel
    Freire, Marta
    Gonzalez, Antonio J.
    Moliner, Laura
    Mondejar, Alvaro
    Morera-Ballester, Constantino
    Prior, John
    Sanchez, David
    Benlloch, Jose M.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2024, 8 (07) : 839 - 849