A 4D-PET block detector based on Silicon Photomultipliers

被引:0
|
作者
Marcatili, Sara [1 ]
Belcari, Nicola [1 ]
Bisogni, Maria G. [1 ]
Collazuol, Gianmaria [2 ]
Pedreschi, Elena [2 ]
Spinella, Franco [2 ]
Corsi, Francesco [3 ]
Foresta, Maurizio [3 ]
Marzocca, Cristoforo [3 ]
Matarrese, Gianvito [3 ]
Sportelli, Giancarlo
Guerra, Pedro [4 ]
Santos, Andres [5 ]
Del Guerra, Alberto [1 ,5 ]
机构
[1] Univ Pisa, I-56127 Pisa, Italy
[2] Univ Pisa, Ist Nazl Fis Nucl, I-56127 Pisa, Italy
[3] Politecnh Bari, Ist Nazl Fis Nucl, I-70100 Bari, Italy
[4] CIBER BBN, EEI Modulo, E-50018 Zaragoza, Spain
[5] Univ Politecn Madrid, E-28040 Madrid, Spain
关键词
TIMING RESOLUTION; MATRICES; ENERGY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Next generation PET scanners should fulfill very high requirements in terms of spatial, energy and timing resolution. Modern scanner performances are inherently limited by the use of standard photomultiplier tubes. The use of Silicon Photomultiplier (SiPM) matrices is proposed for the construction of a 4D PET module based on LYSO continuos crystals, which is envisaged to replace the standard PET block detector. The module will provide a submillimetric spatial resolution on the photon hit position, performing at the same time, the Depth Of Interaction (DOI) calculation and the Time Of Flight (TOF) measurement. The use of large area multi-pixel Silicon Photomultiplier (SiPM) detectors requires the development of a multichannel Digital Acquisition system (DAQ) as well as of a dedicated front-end in order not to degrade the intrinsic detector capabilities. At the University of Pisa and INFN Pisa we have developed a flexible and modular DAQ system for the read-out of 2 module in time coincidence for Positron Emission Tomography (PET) applications. Here we describe the acquisition system architecture and its characterization measurements.
引用
收藏
页码:1949 / 1953
页数:5
相关论文
共 50 条
  • [31] Performances comparison of five commercial 4D-PET/CT devices
    Badel, J. N.
    Isnardi, V.
    Spasic, E.
    Donnarieix, D.
    Chemin, A.
    Vrigneaud, J. M.
    Mognetti, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S92 - S93
  • [32] SILICON PHOTOMULTIPLIERS IN PET AND HADRONTHERAPY APPLICATIONS
    Llosa, G.
    Barrio, J.
    Bisogni, M. G.
    Cabello, J.
    Del Guerra, A.
    Gillam, J.
    Lacasta, C.
    Oliver, J.
    Rafecas, M.
    Solaz, C.
    Stankova, V.
    Torres-Espallardo, I.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S111 - S112
  • [33] Phase corrected impairment correction of 4D-PET with help of 4D-CT
    Richter, C.
    Just, U.
    Poenisch, F.
    Enghardt, W.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2008, 184 : 61 - 61
  • [34] Quantitative 4D-PET Reconstruction for Small Animal Using 4D-CBCT
    Zhong, Y.
    Kalantari, F.
    Zhang, Y.
    Wang, J.
    MEDICAL PHYSICS, 2017, 44 (06) : 3291 - 3291
  • [35] Novel Silicon Photomultipliers for PET Application
    Llosa, Gabriela
    Battiston, Roberto
    Bisogni, Maria Giuseppina
    Boscardin, Maurizio
    Collazuol, Gianmaria
    Corsi, Francesco
    Dalla Betta, Gian-Franco
    Del Guerra, Alberto
    Dinu, Nicoleta
    Levi, Giuseppe
    Marcatili, Sara
    Moehrs, Sascha
    Marzocca, Cristoforo
    Piemonte, Claudio
    Pozza, Alberto
    Sbarra, Cristina
    Quadrani, Lucio
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1875 - 1879
  • [36] Comparison of Gating Algorithms in 4D-PET for Mobile Tumor Segmentation
    Jani, S.
    Dahlbom, M.
    White, B.
    Thomas, D.
    Gaudio, S.
    Low, D.
    Lamb, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [37] Quantitation of respiratory motion during 4D-PET/CT acquisition
    Nehmeh, SA
    Erdi, YE
    Pan, T
    Yorke, E
    Mageras, GS
    Rosenzweig, KE
    Schoder, H
    Mostafavi, H
    Squire, O
    Pevsner, A
    Larson, SM
    Humm, JL
    MEDICAL PHYSICS, 2004, 31 (06) : 1333 - 1338
  • [38] Development of a thermal neutron detector based on scintillating fibers and silicon photomultipliers
    Barbagallo, Massimo
    Cosentino, Luigi
    Greco, Giuseppe
    Montereali, Rosa Maria
    Pappalardo, Alfio
    Sciregrave, Carlotta
    Scire, Sergio
    Vincenti, Maria Aurora
    Finocchiaro, Paolo
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (09):
  • [39] The Impact of CT Image Used for Attenuation Correction in 4D-PET
    Cui, Y.
    Bowsher, J.
    Yan, S.
    Cai, J.
    Das, S.
    Yin, F.
    MEDICAL PHYSICS, 2014, 41 (06) : 105 - 105
  • [40] 4D-PET ACQUISITION: COMPARISON BETWEEN 2 SYNCHRONIZATION DEVICES
    Nalis, J.
    Caselles, O.
    Dierickx, L.
    Brillouet, S.
    Ouskili, Z.
    Batatia, H.
    Zerdoud, S.
    Courbon, F.
    RADIOTHERAPY AND ONCOLOGY, 2010, 94 : S23 - S23