Accurate fault location element for series compensated double-circuit transmission lines utilizing negative-sequence phasors

被引:12
|
作者
Nemati, Mojtaba [1 ]
Bigdeli, Mehdi [1 ]
Ghorbani, Amir [2 ]
Mehrjerdi, Hasan [3 ]
机构
[1] Islamic Azad Univ, Dept Elect Engn, Zanjan Branch, Zanjan, Iran
[2] Islamic Azad Univ, Dept Elect Engn, Abhar Branch, Abhar, Iran
[3] Qatar Univ, Dept Elect Engn, Doha, Qatar
关键词
Fault location element (FLE); fault resistance; series compensated lines; double-circuit transmission lines; MOV-protected SC;
D O I
10.1016/j.epsr.2021.107064
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Obtaining the accurate fault location in the series compensated double-circuit transmission lines (SCDCTL) is a challenge due to the presence of series compensator, fault resistance, and mutual the coupling between parallel lines. Although by using the pilot fault location methods, the effect of all the aforementioned factors can be eliminated and the location of the fault can be calculated. However, the number of communication channels available for pilot schemes is limited. In addition, the reliability of the communication links for long transmission lines may be particularly reduced. On the other hand, most of the non-pilot methods need to calculate the series compensator data and the accuracy of the fault location in them depends on the accuracy of the series compensator parameters. To improve the limitation of conventional impedance-based methods, this paper presents a non-pilot accurate fault location element (FLE) for conventional distance relays in SCDCTL. The main concept of the proposed method is considering the proper Kirchhoff voltage law (KVL) loop in the negative sequence circuit of SCDCTL. Consideration of the shunt capacitances of lines ensures accuracy of the achieved fault location formula. It is shown that the designed FLE can improve limitations associated with similar methods such as the dependence of these methods to the fault resistance, mutual coupling between the parallel lines, and the series compensator (SC) parameters. To investigate the performance of the proposed FLE, several factors are considered in the simulation analysis including different fault resistances, fault locations, and fault types. Besides, the influence of current transformer (CT) saturation, measurement errors, external faults, bypassing of the Metal Oxide Varistor (MOV), and effect of noise on the proposed scheme is studied. Evaluation study using PSCAD verify the effectiveness and applicability of the proposed scheme.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] A New Fault Location Algorithm Based on Positive Sequence Current Difference for Double-circuit Three-terminal Transmission Lines
    Zhang S.
    Li Y.
    Chen X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2018, 38 (05): : 1488 - 1495
  • [42] A New Fault Location Algorithm Based on Positive Sequence Current Difference for Double-circuit Three-terminal Transmission Lines
    ZHANG Siqi
    LI Yongli
    CHEN Xiaolong
    中国电机工程学报, 2018, 38 (05) : 1609 - 1609
  • [43] Performance of directional relay on series capacitor compensated parallel double-circuit lines
    Yuping, Zheng
    Yuanyuan, Li
    Shaochun, Zhang
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 2000, 24 (22): : 24 - 31
  • [44] New Fault Location Technique for Series Compensated Transmission Lines
    Kang, Ning
    Liao, Yuan
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2009, 4 (06): : 1385 - 1390
  • [45] Challenges and Recommendations for Fault Location in Series Compensated Transmission Lines
    Bains, Tirath Pal S.
    Zadeh, Mohammad R. Dadash
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [46] A new fault location technique for four-circuit series-compensated transmission lines
    Saber, Ahmed
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2019, 29 (04):
  • [47] Fault location of untransposed double-circuit transmission lines based on an improved Karrenbauer matrix and the QPSO algorithm
    Minan Tang
    Hang Lu
    Bin Li
    Protection and Control of Modern Power Systems, 2023, 8
  • [48] Fault location of untransposed double-circuit transmission lines based on an improved Karrenbauer matrix and the QPSO algorithm
    Tang, Minan
    Lu, Hang
    Li, Bin
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2023, 8 (01)
  • [49] Novel Method of Time-domain Fault Location for Wind Farm Double-circuit Transmission Lines
    Shu H.
    Deng Y.
    Cao P.
    Zhu M.
    Ma Y.
    An N.
    Dianwang Jishu/Power System Technology, 2023, 47 (04): : 1450 - 1459
  • [50] One-end impedance based fault location in double-circuit transmission lines with different configurations
    Ramar, K.
    Low, H. S.
    Ngu, E. E.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 64 : 1159 - 1165