ACCURACY OF IMPLANT IMPRESSIONS WITHOUT IMPRESSION COPINGS: A THREE-DIMENSIONAL ANALYSIS

被引:23
|
作者
Kwon, Joo-Hyun [1 ]
Son, Yong-Ha [2 ]
Han, Chong-Hyun [1 ]
Kim, Sunjai [1 ]
机构
[1] Yonsei Univ, Gangnam Severance Dent Hosp, Coll Dent, Dept Prosthodont, Seoul 135720, South Korea
[2] Yonsei Univ, Coll Dent, Seoul 135720, South Korea
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2011年 / 105卷 / 06期
关键词
IN-VITRO; COMPONENTS; PROSTHESES; PRECISION; SYSTEM; FIT;
D O I
10.1016/S0022-3913(11)60075-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Implant impressions without impression copings can be used for cement-retained implant restorations. A comparison of the accuracy of implant impressions with and without impression copings is needed. Purpose. The purpose of this study was to evaluate and compare the dimensional accuracy of implant definitive casts that are fabricated by implant impressions with and without impression copings. Material and methods. An acrylic resin maxillary model was fabricated, and 3 implant replicas were secured in the right second premolar, first, and second molars. Two impression techniques were used to fabricate definitive casts (n=10). For the coping group (Group C), open tray impression copings were used for the final impressions. For the no-coping group (Group NC), cementable abutments were connected to the implant replicas, and final impressions were made assuming the abutments were prepared teeth. Computerized calculation of the centroids and long axes of the implant or stone abutment replicas was performed. The Mann-Whitney U test analyzed the amount of linear and rotational distortion between groups (alpha = .05). Results. At the first molar site, Group NC showed significantly greater linear distortion along the Y-axis, with a small difference between the groups (Group C, 7.8 +/- 7.4 mu m; Group NC, 19.5 +/- 12.2). At the second molar site, increased distortion was noted in Group NC for every linear and rotational variable, except for linear distortion along the Z-axis. Conclusions. Implant impression with open tray impression copings produced more accurate definitive casts than those fabricated without impression copings, especially those with greater inter-abutment distance. (J Prosthet Dent 2011;105:367-373)
引用
收藏
页码:367 / 373
页数:7
相关论文
共 50 条
  • [1] Three-Dimensional Accuracy of Plastic Transfer Impression Copings for Three Implant Systems
    Teo, Juin Wei
    Tan, Keson B.
    Nicholls, Jack I.
    Wong, Keng Mun
    Uy, Joanne
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) : 577 - 584
  • [2] Three-dimensional accuracy of innovative implant-level impression techniques with plastic snap-on impression copings
    Asli, Hamid Neshandar
    Hemmati, Yasamin Babaee
    Falahchai, Mehran
    DENTAL AND MEDICAL PROBLEMS, 2021, 58 (03) : 351 - 357
  • [3] In Vitro Three-Dimensional Accuracy of Digital Implant Impressions: The Effect of Implant Angulation
    Chia, Vanessa A.
    Esguerra, Roxanna J.
    Teoh, Khim Hean
    Teo, Juin Wei
    Wong, Keng Mun
    Tan, Keson B.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (02) : 313 - 321
  • [4] Three-Dimensional Accuracy of Digital Implant Impressions: Effects of Different Scanners and Implant Level
    Chew, Amelia A.
    Esguerra, Roxanna J.
    Teoh, K. H.
    Wong, K. M.
    Ng, Simon D.
    Tan, Keson B.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 70 - 80
  • [5] Accuracy of Digital vs Conventional Implant Impression Approach: A Three-Dimensional Comparative In Vitro Analysis
    Basaki, Kinga
    Alkumru, Hasan
    De Souza, Grace
    Finer, Yoav
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : 792 - 799
  • [6] Effects of Implant Angulation and Impression Coping Type on the Dimensional Accuracy of Impressions
    Shim, Ji Suk
    Ryu, Jae Jun
    Shin, Sang Wan
    Lee, Jeong Yol
    IMPLANT DENTISTRY, 2015, 24 (06) : 726 - 729
  • [7] Three-Dimensional Accuracy of Conventional Versus Digital Complete Arch Implant Impressions
    Albayrak, Berkman
    Sukotjo, Cortino
    Wee, Alvin G.
    Korkmaz, Ismail Hakki
    Bayindir, Funda
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (02): : 163 - 170
  • [8] Three-Dimensional Accuracy of a Digitally Coded Healing Abutment Implant Impression System
    Ng, Simon D.
    Tan, Keson B.
    Teoh, K. H.
    Cheng, Ansgar C.
    Nicholls, Jack I.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (04) : 927 - 936
  • [9] Effect of Multiple Use of Impression Copings on the Accuracy of Implant Transfer
    Alikhasi, Marzieh
    Bassir, Seyed Hossein
    Naini, Roshanak Baghai
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 408 - 414
  • [10] Influence of impression material and time on the 3-dimensional accuracy of implant impressions
    Holst, Stefan
    Blatz, Markus B.
    Bergler, Michael
    Goellner, Matthias
    Wichmann, Manfred
    QUINTESSENCE INTERNATIONAL, 2007, 38 (01): : 67 - 73