In Vitro Three-Dimensional Accuracy of Digital Implant Impressions: The Effect of Implant Angulation

被引:61
|
作者
Chia, Vanessa A. [1 ]
Esguerra, Roxanna J. [2 ]
Teoh, Khim Hean [1 ]
Teo, Juin Wei [3 ]
Wong, Keng Mun [2 ]
Tan, Keson B. [2 ]
机构
[1] Natl Dent Ctr Singapore, Dept Restorat Dent, Singapore, Singapore
[2] Natl Univ Singapore, Fac Dent, 11 Lower Kent Ridge Rd, Singapore 119083, Singapore
[3] Khoo Teck Puat Hosp, Dept Dent, Singapore, Singapore
关键词
accuracy; coordinate measuring machine; digital; implant impression; scan body; three-dimensional; DEFINITIVE CASTS; CONNECTION; PROSTHESES; SYSTEMS; FIT; COMPONENTS; PRECISION; PARALLEL; DEPTH;
D O I
10.11607/jomi.5087
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the three-dimensional (3D) accuracy of conventional impressions (CIs) with digital scans (DSs) using an intraoral scanner (IOS) with intraoral scan bodies (SBs) and varying buccolingual interimplant angulations. A secondary aim was to measure the SB machining tolerance and height with and without application of torque. Materials and Methods: Three master models (MMs) with two implants simulating an implant-supported three-unit fixed partial denture for bone-level implants were used. The implants had buccolingual interimplant angulations of 0, 10, and 20 degrees. Test models for the CI test groups were made with impression copings and polyether impressions. SBs were attached to the MMs, tightened to 15-Ncm torque, and scanned by an IOS for the DS test groups (six test groups, n = 5). A coordinate measuring machine measured linear distortions (dx, dy, dz), 3D distortions (dR), angular distortions (d.x, d.y), and absolute angular distortions (Absd.x, Absd.y) of the physical CI test models and STL files of the DS virtual models relative to the MMs. Metrology software allowed both physical and virtual measurement of geometric targets that were comparable and allowed computation of relative displacements of implant centroids and axes. Results: Mean dR ranged from 31 +/- 14.2 to 45 +/- 3.4 mu m for DS and 18 +/- 8.4 to 36 +/- 6.5 mu m for the CI test groups. Mean Absd.x ranged from 0.041 +/- 0.0318 to 0.794 +/- 0.2739 degrees for DS and 0.073 +/- 0.0618 to 0.545 +/- 0.0615 degrees for the CI test groups. Mean Absd.y ranged from 0.075 +/- 0.0615 to 0.111 +/- 0.0639 degrees for DS and 0.106 +/- 0.0773 to 0.195 +/- 0.1317 degrees for the CI test groups. Two-way analysis of variance showed that the impression technique (P = .012) and implant angulations (P = .007) had a significant effect on dR. Distortions were mostly in the negative direction for DS test groups. Perfect coaxiality of the SB with the implant was never achieved. For SB to implant machining tolerances, the mean absolute horizontal displacement ranged from 4 +/- 1.2 to 7 +/- 2.3 mu m. The SB dz was -5 +/- 3.2 mu m, which increased in the negative direction to -11 +/- 4.9 mu m with torque application (P = .002). Conclusion: Distortions were found for both DS and CI test groups. The best accuracy was obtained with CIs for parallel implants. With angulated implants, conventional and DSs were not significantly different. Excessive torque application that causes negative dz for SB fit would position the virtual implant at a deeper location compared with reality, resulting in possible framework misfit.
引用
收藏
页码:313 / 321
页数:9
相关论文
共 50 条
  • [1] Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study
    Jo, Si-Hoon
    Kim, Kyoung-Ii
    Seo, Jae-Min
    Song, Kwang-Yeob
    Park, Ju-Mi
    Ahn, Seung-Geun
    JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (04): : 128 - 133
  • [2] Three-Dimensional Accuracy of Digital Implant Impressions: Effects of Different Scanners and Implant Level
    Chew, Amelia A.
    Esguerra, Roxanna J.
    Teoh, K. H.
    Wong, K. M.
    Ng, Simon D.
    Tan, Keson B.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 70 - 80
  • [3] Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation
    Abduo, Jaafar
    Palamara, Joseph E. A.
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [4] Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation
    Jaafar Abduo
    Joseph E. A. Palamara
    International Journal of Implant Dentistry, 7
  • [5] Three-Dimensional Accuracy of Conventional Versus Digital Complete Arch Implant Impressions
    Albayrak, Berkman
    Sukotjo, Cortino
    Wee, Alvin G.
    Korkmaz, Ismail Hakki
    Bayindir, Funda
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (02): : 163 - 170
  • [6] Three-Dimensional Accuracy of Digital Impression versus Conventional Method: Effect of Implant Angulation and Connection Type
    Alikhasi, Marzieh
    Siadat, Hakime
    Nasirpour, Alireza
    Hasanzade, Mahya
    INTERNATIONAL JOURNAL OF DENTISTRY, 2018, 2018
  • [7] Comparison of Three-Dimensional Accuracy of Digital and Conventional Implant Impressions: Effect of Interimplant Distance in an Edentulous Arch
    Tan, Ming Yi
    Yee, Sophia Hui Xin
    Wong, Keng Mun
    Tan, Ying Han
    Tan, Keson Beng Choon
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (02) : 366 - 380
  • [8] Effects of Implant Angulation and Impression Coping Type on the Dimensional Accuracy of Impressions
    Shim, Ji Suk
    Ryu, Jae Jun
    Shin, Sang Wan
    Lee, Jeong Yol
    IMPLANT DENTISTRY, 2015, 24 (06) : 726 - 729
  • [9] ACCURACY OF IMPLANT IMPRESSIONS WITHOUT IMPRESSION COPINGS: A THREE-DIMENSIONAL ANALYSIS
    Kwon, Joo-Hyun
    Son, Yong-Ha
    Han, Chong-Hyun
    Kim, Sunjai
    JOURNAL OF PROSTHETIC DENTISTRY, 2011, 105 (06): : 367 - 373
  • [10] Trueness of digital implant impressions based on implant angulation and scan body materials
    Jae-Hyun Lee
    Jae-Hwi Bae
    Su Young Lee
    Scientific Reports, 11