Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study

被引:31
|
作者
Jo, Si-Hoon [1 ]
Kim, Kyoung-Ii [1 ]
Seo, Jae-Min [1 ]
Song, Kwang-Yeob [1 ]
Park, Ju-Mi [1 ]
Ahn, Seung-Geun [1 ]
机构
[1] Chonbuk Natl Univ, Coll Dent, Dept Prosthodont, Jeonju 561756, Chonbuk, South Korea
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2010年 / 2卷 / 04期
关键词
Impression coping; Implant angulation; Master cast accuracy;
D O I
10.4047/jap.2010.2.4.128
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. The purpose of this study was to compare the accuracy of the implant master cast according to the type (pick-up, transfer) and the length (long, short) of the impression copings. MATERIALS AND METHODS. The metal master cast was fabricated with three internal connection type implant analogs (Osstem GS III analog), embedded parallel and with 10 of mesial angulation to the center analog. Four types of impression coping were prepared with different combinations of types (transfer, pick-up) and lengths (long, short) of the coping. The impressions were made using vinyl polysiloxane (one step, heavy + light body) with an individual tray, and 10 impressions were made for each group. Eventually, 40 experimental casts were produced. Then, the difference in the distance between the master cast and the experimental cast were measured, and the error rate was determined. The analysis of variance was performed using the SPSS (v 12.0) program (alpha = .05), and the statistical significance was set at P < .05. RESULTS. The ANOVA showed that the pick-up type impression coping exhibited a significantly lower error rate than the transfer type. However, no significant difference was observed with respect to the length of the impression coping. Additionally, no significant difference was observed between the parallel and mesial angulated groups. CONCLUSION. Within the limitations of this study, the pick-up type impression coping exhibited a more accurate implant master cast than the transfer type in parallel group. The accuracy of the implant master cast did not differ for different lengths of impression coping of at least 11 mm. Additionally, the accuracy of the implant cast was not different for the parallel and 10 degrees mesial angulated groups. [J Adv Prosthodont 2010;2:128-33]
引用
收藏
页码:128 / 133
页数:6
相关论文
共 50 条
  • [1] Effects of Implant Angulation and Impression Coping Type on the Dimensional Accuracy of Impressions
    Shim, Ji Suk
    Ryu, Jae Jun
    Shin, Sang Wan
    Lee, Jeong Yol
    IMPLANT DENTISTRY, 2015, 24 (06) : 726 - 729
  • [2] In Vitro Three-Dimensional Accuracy of Digital Implant Impressions: The Effect of Implant Angulation
    Chia, Vanessa A.
    Esguerra, Roxanna J.
    Teoh, Khim Hean
    Teo, Juin Wei
    Wong, Keng Mun
    Tan, Keson B.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (02) : 313 - 321
  • [3] Accuracy of Implant Impressions with Different Impression Coping Types and Shapes
    Rashidan, Nayereh
    Alikhasi, Marzieh
    Samadizadeh, Samad
    Beyabanaki, Elahe
    Kharazifard, Mohammad Javad
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (02) : 218 - 225
  • [4] The impact of impression coping geometrical design on accuracy of implant impressions: an experimental study
    Motaz Osman
    Neamat Hassan Abubakr
    Ahmed Suliman
    Hassan Ziada
    International Journal of Implant Dentistry, 6
  • [5] The impact of impression coping geometrical design on accuracy of implant impressions: an experimental study
    Osman, Motaz
    Abubakr, Neamat Hassan
    Suliman, Ahmed
    Ziada, Hassan
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [6] Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation
    Abduo, Jaafar
    Palamara, Joseph E. A.
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [7] Effect of different impression coping and scan body designs on the accuracy of conventional versus digital implant impressions: An in vitro study
    Alkindi, Shaikha
    Hamdoon, Zaid
    Aziz, Ahmed M.
    JOURNAL OF DENTISTRY, 2024, 146
  • [8] Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation
    Jaafar Abduo
    Joseph E. A. Palamara
    International Journal of Implant Dentistry, 7
  • [9] Effect of implant angulation and impression technique on impressions of Nobel Active implants
    Hazboun, Gillian Brewer Alexander
    Masri, Radi
    Romberg, Elaine
    Kemp, Joanna
    Driscoll, Carl F.
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (05): : 425 - 431
  • [10] Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: An in vitro study
    Lee, Heeje
    Ercoli, Carlo
    Funkenbusch, Paul D.
    Feng, Changyong
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 99 (02): : 107 - 113