ACCURACY OF IMPLANT IMPRESSIONS WITHOUT IMPRESSION COPINGS: A THREE-DIMENSIONAL ANALYSIS

被引:23
|
作者
Kwon, Joo-Hyun [1 ]
Son, Yong-Ha [2 ]
Han, Chong-Hyun [1 ]
Kim, Sunjai [1 ]
机构
[1] Yonsei Univ, Gangnam Severance Dent Hosp, Coll Dent, Dept Prosthodont, Seoul 135720, South Korea
[2] Yonsei Univ, Coll Dent, Seoul 135720, South Korea
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2011年 / 105卷 / 06期
关键词
IN-VITRO; COMPONENTS; PROSTHESES; PRECISION; SYSTEM; FIT;
D O I
10.1016/S0022-3913(11)60075-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Implant impressions without impression copings can be used for cement-retained implant restorations. A comparison of the accuracy of implant impressions with and without impression copings is needed. Purpose. The purpose of this study was to evaluate and compare the dimensional accuracy of implant definitive casts that are fabricated by implant impressions with and without impression copings. Material and methods. An acrylic resin maxillary model was fabricated, and 3 implant replicas were secured in the right second premolar, first, and second molars. Two impression techniques were used to fabricate definitive casts (n=10). For the coping group (Group C), open tray impression copings were used for the final impressions. For the no-coping group (Group NC), cementable abutments were connected to the implant replicas, and final impressions were made assuming the abutments were prepared teeth. Computerized calculation of the centroids and long axes of the implant or stone abutment replicas was performed. The Mann-Whitney U test analyzed the amount of linear and rotational distortion between groups (alpha = .05). Results. At the first molar site, Group NC showed significantly greater linear distortion along the Y-axis, with a small difference between the groups (Group C, 7.8 +/- 7.4 mu m; Group NC, 19.5 +/- 12.2). At the second molar site, increased distortion was noted in Group NC for every linear and rotational variable, except for linear distortion along the Z-axis. Conclusions. Implant impression with open tray impression copings produced more accurate definitive casts than those fabricated without impression copings, especially those with greater inter-abutment distance. (J Prosthet Dent 2011;105:367-373)
引用
收藏
页码:367 / 373
页数:7
相关论文
共 50 条
  • [41] Three-dimensional analysis of marginal and internal fit of copings fabricated with polyetherketoneketone (PEKK) and zirconia
    Bae, So-Yeon
    Park, Jin-Young
    Jeong, Il-Do
    Kim, Hae-Young
    Kim, Ji-Hwan
    Kim, Woong-Chul
    JOURNAL OF PROSTHODONTIC RESEARCH, 2017, 61 (02) : 106 - 112
  • [42] Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: An in vitro study
    Lee, Heeje
    Ercoli, Carlo
    Funkenbusch, Paul D.
    Feng, Changyong
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 99 (02): : 107 - 113
  • [43] Three-dimensional approach to thresholding seal impressions
    Horiuchi, T
    Rioux, M
    Haruki, R
    Yamamoto, K
    Yamada, H
    Toraichi, K
    PATTERN RECOGNITION, 1996, 29 (05) : 719 - 724
  • [44] Three-Dimensional Accuracy of Guided Implant Placement: Indirect Assessment of Clinical Outcomes
    Platzer, Susanne
    Bertha, Georg
    Heschl, Alexander
    Wegscheider, Walther A.
    Lorenzoni, Martin
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (05) : 724 - 734
  • [45] Three-dimensional accuracy of implant placement in a computer-assisted navigation system
    Chiu, Wai-kuen
    Luk, Wai-kuen
    Cheung, Lim-kwong
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2006, 21 (03) : 465 - 470
  • [46] Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection
    Wenz, Hans-Juergen
    Hertrampf, Katrin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (01) : 39 - 47
  • [47] Does Splinting the Direct Copings Increase the Impression Accuracy of Two-Unit Nonparallel Implant Restorations? A Systematic Review and Meta-analysis
    Ma, Yun
    Al-Radhi, Ruqayya Yahya Zaid
    Jiang, Lei
    Yu, Hao
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 653 - 659
  • [48] Accuracy Analysis of Three-Dimensional Modeling of a Multi-Level UAV without Control Points
    Wang, Dejiang
    Shu, Huazhen
    BUILDINGS, 2022, 12 (05)
  • [49] Digital Evaluation of the Dimensional Accuracy of Four Different Implant Impression Techniques
    Ozcelik, T. B.
    Ozcan, I.
    Ozan, O.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2018, 21 (10) : 1247 - 1253
  • [50] The Effect of Implant Connection Length on the Dimensional Impression Accuracy of Inclined Implants
    Ehsani, Sara
    Siadat, Hakimeh
    Alikhasi, Marzieh
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (06) : E315 - E320