Rapid detection of SARS-CoV-2 antibodies using electrochemical impedance-based detector

被引:143
|
作者
Rashed, Mohamed Z. [1 ]
Kopechek, Jonathan A. [2 ]
Priddy, Mariah C. [2 ]
Hamorsky, Krystal T. [3 ]
Palmer, Kenneth E. [3 ]
Mittal, Nikhil [4 ]
Valdez, Joseph [4 ]
Flynn, Joseph [5 ]
Williams, Stuart J. [1 ]
机构
[1] Univ Louisville, Dept Mech Engn, 200 Sackett Hall, Louisville, KY 40208 USA
[2] Univ Louisville, Dept Bioengn, Louisville, KY 40208 USA
[3] Univ Louisville, Ctr Predict Med Biodefense & Emerging Infect Dis, Louisville, KY 40208 USA
[4] Agilent Technolo Inc, ACEA Biosci, San Diego, CA 92121 USA
[5] Norton Healthcare Inc, Louisville, KY 40202 USA
来源
关键词
Impedance spectroscopy; SARS-CoV-2; Capacitive immunosensors; Antibodies; Label-free; DIELECTRIC-SPECTROSCOPY;
D O I
10.1016/j.bios.2020.112709
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Coronavirus disease (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was classified as a pandemic by the World Health Organization and has caused over 550,000 deaths worldwide as of July 2020. Accurate and scalable point-of-care devices would increase screening, diagnosis, and monitoring of COVID-19 patients. Here, we demonstrate rapid label-free electrochemical detection of SARS-CoV-2 antibodies using a commercially available impedance sensing platform. A 16-well plate containing sensing electrodes was pre-coated with receptor binding domain (RBD) of SARS-CoV-2 spike protein, and subsequently tested with samples of anti-SARS-CoV-2 monoclonal antibody CR3022 (0.1 mu g/ml, 1.0 mu g/ml, 10 mu g/ml). Subsequent blinded testing was performed on six serum specimens taken from COVID-19 and non-COVID-19 patients (1:100 dilution factor). The platform was able to differentiate spikes in impedance measurements from a negative control (1% milk solution) for all CR3022 samples. Further, successful differentiation and detection of all positive clinical samples from negative control was achieved. Measured impedance values were consistent when compared to standard ELISA test results showing a strong correlation between them (R-2 = 0.9). Detection occurs in less than five minutes and the well-based platform provides a simplified and familiar testing interface that can be readily adaptable for use in clinical settings.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Evaluation of eleven rapid tests for detection of antibodies against SARS-CoV-2
    Tollanes, Mette C.
    Kran, Anne-Marte Bakken
    Abildsnes, Eirik
    Jenum, Pal A.
    Breivik, Anne C.
    Sandberg, Sverre
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (09) : 1595 - 1600
  • [22] Evaluation of 32 rapid tests for detection of antibodies against SARS-CoV-2
    Tollanes, Mette C.
    Jenum, Pal A.
    Kierkegaard, Helene
    Abildsnes, Eirik
    Baevre-Jensen, Roar Magne
    Breivik, Anne C.
    Sandberg, Sverre
    CLINICA CHIMICA ACTA, 2021, 519 : 133 - 139
  • [23] Rapid lateral flow tests for the detection of SARS-CoV-2 neutralizing antibodies
    Wang, Jianfu J.
    Zhang, Nan
    Richardson, Sarah A.
    Wu, Jin V.
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2021, 21 (04) : 363 - 370
  • [24] Electrochemical Biosensors for SARS-CoV-2 Detection
    Andrianova M.S.
    Panova O.S.
    Titov A.A.
    Komarova N.V.
    Kuznetsov A.E.
    Moscow University Chemistry Bulletin, 2023, 78 (5) : 231 - 254
  • [25] Rapid and Sensitive Detection of Inactivated SARS-CoV-2 Virus via Fiber-Optic and Electrochemical Impedance Spectroscopy Based Aptasensors
    Xiao, Can
    Wang, Nan
    Zhao, Yuechao
    Liu, Xuemei
    Li, Hui
    Huang, Aixue
    Wang, Lin
    Lou, Xinhui
    Gao, Bo
    Shao, Ningsheng
    BIOSENSORS-BASEL, 2024, 14 (05):
  • [26] Rapid Detection of SARS-CoV-2 Antigens and Antibodies Using OFET Biosensors Based on a Soft and Stretchable Semiconducting Polymer
    Ditte, Kristina
    Le, Trang Anh Nguyen
    Ditzer, Oliver
    Bojorquez, Diana Isabel Sandoval
    Chae, Soosang
    Bachmann, Michael
    Baraban, Larysa
    Lissel, Franziska
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2023, 9 (05) : 2140 - 2147
  • [27] Column Agglutination Assay Using Polystyrene Microbeads for Rapid Detection of Antibodies against SARS-CoV-2
    Kesarwani, Vidhishri
    Walker, Julia A.
    Henderson, Edward C.
    Huynh, Gabriel
    McLiesh, Heather
    Graham, Maryza
    Wieringa, Megan
    Holl, Mark M. Banaszak
    Garnier, Gil
    Corrie, Simon R.
    ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (02) : 2501 - 2509
  • [28] A Novel Peptide-Based Detection of SARS-CoV-2 Antibodies
    Bulut, Aliye
    Temur, Betul Z.
    Kirimli, Ceyhun E.
    Gok, Ozgul
    Balcioglu, Bertan K.
    Ozturk, Hasan U.
    Uyar, Neval Y.
    Kanlidere, Zeynep
    Kocagoz, Tanil
    Can, Ozge
    BIOMIMETICS, 2023, 8 (01)
  • [29] Selective Electrochemical Detection of SARS-CoV-2 Using Deep Learning
    Gecgel, Ozhan
    Ramanujam, Ashwin
    Botte, Gerardine G.
    VIRUSES-BASEL, 2022, 14 (09):
  • [30] Rapid and accurate detection of SARS-CoV-2 using the RHAM technology
    Zhuo Xiao
    Xiaoli Liu
    Xiaolong Kang
    Yaoheng Feng
    Lijun Zheng
    Chong Chen
    Scientific Reports, 13