Rapid detection of SARS-CoV-2 antibodies using electrochemical impedance-based detector

被引:143
|
作者
Rashed, Mohamed Z. [1 ]
Kopechek, Jonathan A. [2 ]
Priddy, Mariah C. [2 ]
Hamorsky, Krystal T. [3 ]
Palmer, Kenneth E. [3 ]
Mittal, Nikhil [4 ]
Valdez, Joseph [4 ]
Flynn, Joseph [5 ]
Williams, Stuart J. [1 ]
机构
[1] Univ Louisville, Dept Mech Engn, 200 Sackett Hall, Louisville, KY 40208 USA
[2] Univ Louisville, Dept Bioengn, Louisville, KY 40208 USA
[3] Univ Louisville, Ctr Predict Med Biodefense & Emerging Infect Dis, Louisville, KY 40208 USA
[4] Agilent Technolo Inc, ACEA Biosci, San Diego, CA 92121 USA
[5] Norton Healthcare Inc, Louisville, KY 40202 USA
来源
关键词
Impedance spectroscopy; SARS-CoV-2; Capacitive immunosensors; Antibodies; Label-free; DIELECTRIC-SPECTROSCOPY;
D O I
10.1016/j.bios.2020.112709
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Coronavirus disease (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was classified as a pandemic by the World Health Organization and has caused over 550,000 deaths worldwide as of July 2020. Accurate and scalable point-of-care devices would increase screening, diagnosis, and monitoring of COVID-19 patients. Here, we demonstrate rapid label-free electrochemical detection of SARS-CoV-2 antibodies using a commercially available impedance sensing platform. A 16-well plate containing sensing electrodes was pre-coated with receptor binding domain (RBD) of SARS-CoV-2 spike protein, and subsequently tested with samples of anti-SARS-CoV-2 monoclonal antibody CR3022 (0.1 mu g/ml, 1.0 mu g/ml, 10 mu g/ml). Subsequent blinded testing was performed on six serum specimens taken from COVID-19 and non-COVID-19 patients (1:100 dilution factor). The platform was able to differentiate spikes in impedance measurements from a negative control (1% milk solution) for all CR3022 samples. Further, successful differentiation and detection of all positive clinical samples from negative control was achieved. Measured impedance values were consistent when compared to standard ELISA test results showing a strong correlation between them (R-2 = 0.9). Detection occurs in less than five minutes and the well-based platform provides a simplified and familiar testing interface that can be readily adaptable for use in clinical settings.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Rapid and accurate detection of SARS-CoV-2 using the RHAM technology
    Xiao, Zhuo
    Liu, Xiaoli
    Kang, Xiaolong
    Feng, Yaoheng
    Zheng, Lijun
    Chen, Chong
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [32] Rapid and accurate agglutination-based testing for SARS-CoV-2 antibodies
    Esmail, Sally
    Knauer, Michael J.
    Abdoh, Husam
    Voss, Courtney
    Chin-Yee, Benjamin
    Stogios, Peter
    Seitova, Almagul
    Hutchinson, Ashley
    Yusifov, Farhad
    Skarina, Tatiana
    Evdokimova, Elena
    Ackloo, Suzanne
    Lowes, Lori
    Hedley, Benjamin D.
    Bhayana, Vipin
    Chin-Yee, Ian
    Li, Shawn S-C
    CELL REPORTS METHODS, 2021, 1 (02):
  • [33] Ultrasensitive electrochemical biosensors based on zinc sulfide/graphene hybrid for rapid detection of SARS-CoV-2
    Shatila Sarwar
    Mao-Chia Lin
    Carolina Amezaga
    Zhen Wei
    Etinosa Iyayi
    Haseena Polk
    Ruigang Wang
    Honghe Wang
    Xinyu Zhang
    Advanced Composites and Hybrid Materials, 2023, 6
  • [34] Ultrasensitive electrochemical biosensors based on zinc sulfide/graphene hybrid for rapid detection of SARS-CoV-2
    Sarwar, Shatila
    Lin, Mao-Chia
    Amezaga, Carolina
    Wei, Zhen
    Iyayi, Etinosa
    Polk, Haseena
    Wang, Ruigang
    Wang, Honghe
    Zhang, Xinyu
    ADVANCED COMPOSITES AND HYBRID MATERIALS, 2023, 6 (01)
  • [35] Towards an Electrochemical Immunosensor for the Detection of Antibodies against SARS-CoV-2 Spike Protein
    Liustrovaite, Viktorija
    Drobysh, Maryia
    Rucinskiene, Alma
    Baradoke, Ausra
    Ramanaviciene, Almira
    Plikusiene, Ieva
    Samukaite-Bubniene, Urte
    Viter, Roman
    Chen, Chien-Fu
    Ramanavicius, Arunas
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (03)
  • [36] Functionalized TiO2 Nanotube-Based Electrochemical Biosensor for Rapid Detection of SARS-CoV-2
    Vadlamani, Bhaskar S.
    Uppal, Timsy
    Verma, Subhash C.
    Misra, Mano
    SENSORS, 2020, 20 (20) : 1 - 10
  • [37] CRISPR-based assays for rapid detection of SARS-CoV-2
    Javalkote, Vivek S.
    Kancharla, Nagesh
    Bhadra, Bhaskar
    Shukla, Manish
    Soni, Badrish
    Sapre, Ajit
    Goodin, Michael
    Bandyopadhyay, Anindya
    Dasgupta, Santanu
    METHODS, 2022, 203 : 594 - 603
  • [38] ELISA detection of SARS-CoV-2 antibodies in saliva
    Melanie A. MacMullan
    Albina Ibrayeva
    Kylie Trettner
    Laura Deming
    Sudipta Das
    Frances Tran
    Jose Ricardo Moreno
    Joseph G. Casian
    Prithivi Chellamuthu
    Jeffrey Kraft
    Kenneth Kozak
    Fred E. Turner
    Vladimir I. Slepnev
    Lydia M. Le Page
    Scientific Reports, 10
  • [39] Evaluation of three immunochromatographic tests for rapid detection of antibodies against SARS-CoV-2
    Guedez-Lopez, Gladys Virginia
    Alguacil-Guillen, Marina
    Gonzalez-Donapetry, Patricia
    Bloise, Ivan
    Tornero-Marin, Carolina
    Gonzalez-Garcia, Juan
    Mingorance, Jesus
    Garcia-Rodriguez, Julio
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2020, 39 (12) : 2289 - 2297
  • [40] Performance of Commercially Available Rapid Serological Assays for the Detection of SARS-CoV-2 Antibodies
    Hashem, Anwar M.
    Alhabbab, Rowa Y.
    Algaissi, Abdullah
    Alfaleh, Mohamed A.
    Hala, Sharif
    Abujamel, Turki S.
    Elassouli, M-Zaki
    AL-Somali, Afrah A.
    Alofi, Fadwa S.
    Khogeer, Asim A.
    Alkayyal, Almohanad A.
    Mahmoud, Ahmad Bakur
    Almontashiri, Naif A. M.
    Pain, Arnab
    PATHOGENS, 2020, 9 (12): : 1 - 10