The simulation and reconstruction of mixed detector cylinder PET system

被引:0
|
作者
Xu, Hao [1 ]
Wang, Shuai [1 ]
Shang, Yueying [1 ]
Cao, Wencai [1 ]
Gao, Min [1 ]
Kao, Chien-Min [3 ]
Xie, Qingguo [1 ,2 ]
Xiao, Peng [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, Biomed Engn Dept, Wuhan, Hubei, Peoples R China
[2] Wuhan Natl Lab Optoelect, Wuhan, Hubei, Peoples R China
[3] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Spatial resolution of a PET system depends on the size of crystal to some extent. In general, the smaller the size of each crystal, the higher the spatial resolution of the PET system. The problem is that with the crystal size becomes smaller, more electronic channels will he needed and the cost of the PET system will increase. Besides, sometimes when imaging some organ like bladder, high spatial resolution is not that necessary. To fix these problems, here we put forward a new method that combines the high spatial resolution crystal with the normal spatial resolution crystal to construct a novel mixed detector module and then we used this module to construct a cylinder PET system. One part used small-size crystals and another part used normal-size crystals in this detector module. Inspired by this method, we can combine high resolution detector module with existing PET machine to construct a mixed detector PET system very quickly. The results demonstrated that these kind of mixed detector cylinder PET system had a good combination of this two kinds of crystals, and we can get different quality reconstruction image by adjusting the position of the target.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] SMART (SiMulAtion and ReconsTruction) PET: an efficient PET simulation-reconstruction tool
    Pfaehler, Elisabeth
    De Jong, Johan R.
    Dierckx, Rudi A. J. O.
    van Velden, Floris H. P.
    Boellaard, Ronald
    EJNMMI PHYSICS, 2018, 5
  • [2] SMART (SiMulAtion and ReconsTruction) PET: an efficient PET simulation-reconstruction tool
    Elisabeth Pfaehler
    Johan R. De Jong
    Rudi A. J. O. Dierckx
    Floris H. P. van Velden
    Ronald Boellaard
    EJNMMI Physics, 5
  • [3] SMART(SiMulAtion and ReconsTruction) PET: An efficient PET simulation-reconstruction tool
    Pfaehler, E.
    Boellaard, R.
    De Jong, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S343 - S344
  • [4] An analysis system for PET detector
    Liu, HC
    Liang, HC
    OPTICAL SENSING, IMAGING, AND MANIPULATION FOR BIOLOGICAL AND BIOMEDICAL APPLICATIONS, 2000, 4082 : 255 - 260
  • [5] Reconstruction of Detector Scattered Events to Improve PET Sensitivity
    Rothfuss, Harold E.
    Panin, Vladimir Y.
    Aykac, Mehmet
    Martin, Victoria C.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [6] Detector description software for simulation, reconstruction and visualisation
    Arce, P
    PROCEEDINGS OF CHEP 2001, 2001, : 526 - 529
  • [7] Simulation and reconstruction of the PANDA Barrel DIRC detector
    Patsyuk, M.
    Schwarz, C.
    Dutta, D.
    Goetzen, K.
    Peters, K.
    Schwiening, J.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [8] Comparison of Positioning Algorithms for a PET Detector: A Simulation Study
    Talat, D.
    Guvenis, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S412 - S412
  • [9] Efficient image reconstruction for a small animal PET system with dual-layer-offset detector design
    Cheng, Li
    Lyu, Zhenlei
    Liu, Hui
    Wu, Jing
    Jia, Chao
    Wu, Yuanguang
    Ji, Yingcai
    Jiang, Nianming
    Ma, Tianyu
    Liu, Yaqiang
    MEDICAL PHYSICS, 2024, 51 (04) : 2772 - 2787
  • [10] Simulation of Compton reconstruction in liquid xenon PET
    Bryman, Douglas
    Kurchaninov, Leonid
    Lu, Philip
    Retiere, Fabriece
    Sossi, Vesna
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4419 - +