The simulation and reconstruction of mixed detector cylinder PET system

被引:0
|
作者
Xu, Hao [1 ]
Wang, Shuai [1 ]
Shang, Yueying [1 ]
Cao, Wencai [1 ]
Gao, Min [1 ]
Kao, Chien-Min [3 ]
Xie, Qingguo [1 ,2 ]
Xiao, Peng [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, Biomed Engn Dept, Wuhan, Hubei, Peoples R China
[2] Wuhan Natl Lab Optoelect, Wuhan, Hubei, Peoples R China
[3] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Spatial resolution of a PET system depends on the size of crystal to some extent. In general, the smaller the size of each crystal, the higher the spatial resolution of the PET system. The problem is that with the crystal size becomes smaller, more electronic channels will he needed and the cost of the PET system will increase. Besides, sometimes when imaging some organ like bladder, high spatial resolution is not that necessary. To fix these problems, here we put forward a new method that combines the high spatial resolution crystal with the normal spatial resolution crystal to construct a novel mixed detector module and then we used this module to construct a cylinder PET system. One part used small-size crystals and another part used normal-size crystals in this detector module. Inspired by this method, we can combine high resolution detector module with existing PET machine to construct a mixed detector PET system very quickly. The results demonstrated that these kind of mixed detector cylinder PET system had a good combination of this two kinds of crystals, and we can get different quality reconstruction image by adjusting the position of the target.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] Maximum-likelihood estimation. of detector response for PET image reconstruction
    Qi, Jinyi
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3277 - 3280
  • [32] Online detector response calculations for high-resolution PET image reconstruction
    Pratx, Guillem
    Levin, Craig
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (13): : 4023 - 4040
  • [33] Harmonization of PET Image Reconstruction Parameters on Multiple PET/MRI System
    Laforest, Richard
    Khalighi, Mohammad Mehdi
    Byrd, Darrin
    An Hongyu
    Larson, Peder
    Sunderland, John
    Kinahan, Paul
    Hope, Thomas
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [34] Compensation of the spatially-variant detector response function in OSEM PET reconstruction
    Freddi, I.
    Vanzi, E.
    Passeri, A.
    Pupi, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S238 - S238
  • [35] Design and simulation of a positron detector to measure the AIF for dynamic PET.
    Carroll, Liam
    Enger, Shirin
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [36] Computer simulation of four-layer depth of interaction detector for PET
    Sato, M
    Haneishi, H
    Inadama, N
    Murayama, H
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1913 - 1917
  • [37] A novel model-based PET detector block simulation approach
    Szlavecz, A.
    Buekki, T.
    Steinbach, C.
    Benyo, B.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2011, 6 (01) : 27 - 33
  • [38] Optical simulation study on the spatial resolution of a thick monolithic PET detector
    Stockhoff, Mariele
    Van Holen, Roel
    Vandenberghe, Stefaan
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (19):
  • [39] Development of PET Detector for Localization Using MLPE Based on Simulation Data
    Lee, Seung-Jae
    Jo, Byungdu
    Cho, Sun-Young
    JOURNAL OF MAGNETICS, 2023, 28 (04) : 409 - 414
  • [40] Numerical simulation on mixed convection in a porous medium heated by a vertical cylinder
    Li, L
    Kimura, S
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2005, 51 (7-8): : 491 - 494