The simulation and reconstruction of mixed detector cylinder PET system

被引:0
|
作者
Xu, Hao [1 ]
Wang, Shuai [1 ]
Shang, Yueying [1 ]
Cao, Wencai [1 ]
Gao, Min [1 ]
Kao, Chien-Min [3 ]
Xie, Qingguo [1 ,2 ]
Xiao, Peng [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, Biomed Engn Dept, Wuhan, Hubei, Peoples R China
[2] Wuhan Natl Lab Optoelect, Wuhan, Hubei, Peoples R China
[3] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Spatial resolution of a PET system depends on the size of crystal to some extent. In general, the smaller the size of each crystal, the higher the spatial resolution of the PET system. The problem is that with the crystal size becomes smaller, more electronic channels will he needed and the cost of the PET system will increase. Besides, sometimes when imaging some organ like bladder, high spatial resolution is not that necessary. To fix these problems, here we put forward a new method that combines the high spatial resolution crystal with the normal spatial resolution crystal to construct a novel mixed detector module and then we used this module to construct a cylinder PET system. One part used small-size crystals and another part used normal-size crystals in this detector module. Inspired by this method, we can combine high resolution detector module with existing PET machine to construct a mixed detector PET system very quickly. The results demonstrated that these kind of mixed detector cylinder PET system had a good combination of this two kinds of crystals, and we can get different quality reconstruction image by adjusting the position of the target.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] Computer simulation for design of depth encoding multicrystal detector for PET
    Haneishi, H
    Nishiya, S
    Miyake, Y
    Murayama, H
    Omura, T
    Ishibashi, H
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1207 - 1211
  • [22] Simulation study of PET detector limitations using continuous crystals
    Cabello, Jorge
    Etxebeste, Ane
    Llosa, Gabriela
    Ziegler, Sibylle I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (09): : 3673 - 3694
  • [23] Automated detector simulation and reconstruction parametrization using machine learning
    Benjamin, D.
    Chekanov, S., V
    Hopkins, W.
    Li, Y.
    Love, J. R.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (05):
  • [24] A novel technique for the reconstruction and simulation of hits in the CMS Pixel Detector
    Chiochia, V.
    Swartz, M.
    Fehling, D.
    Giurgiu, G.
    Maksimovic, P.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1184 - +
  • [25] Automated Approach to Accurate, Precise, and Fast Detector Simulation and Reconstruction
    Dreyer, Etienne
    Gross, Eilam
    Kobylianskii, Dmitrii
    Mikuni, Vinicius
    Nachman, Benjamin
    Soybelman, Nathalie
    PHYSICAL REVIEW LETTERS, 2024, 133 (21)
  • [26] PET DAQ System for Compressed Sensing Detector Modules
    Kim, Ealgoo
    Hong, Key Jo
    Olcott, Peter D.
    Levin, Craig S.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2798 - 2801
  • [27] A feasibility study of the 3D fluorescent image reconstruction for the simultaneous PET and fluorescent CT Imaging system using depth of interaction PET detector
    Tashima, Hideaki
    Obi, Takashi
    Yamaya, Taiga
    Murayama, Hideo
    Kitamura, Keiji
    Oda, Ichiro
    Yamaguchi, Masahiro
    Ohyama, Nagaaki
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [28] Detector response models for statistical iterative image reconstruction in high resolution PET
    Selivanov, VV
    Picard, Y
    Cadorette, J
    Rodrigue, S
    Lecomte, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 1168 - 1175
  • [29] Detector response models for statistical iterative image reconstruction in high resolution PET
    Selivanov, V.V.
    Picard, Y.
    Cadorette, J.
    Rodrigue, S.
    Lecomte, R.
    IEEE Transactions on Nuclear Science, 2000, 47 (3 III) : 1168 - 1175
  • [30] Projector with Realistic Detector Scatter Modelling for PET List-Mode Reconstruction
    Autret, Awen
    Bert, Julien
    Strauss, Olivier
    Visvikis, Dimitris
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3333 - 3336