SMART (SiMulAtion and ReconsTruction) PET: an efficient PET simulation-reconstruction tool

被引:15
|
作者
Pfaehler, Elisabeth [1 ]
De Jong, Johan R. [1 ]
Dierckx, Rudi A. J. O. [1 ]
van Velden, Floris H. P. [2 ]
Boellaard, Ronald [1 ,3 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[2] Leiden Univ, Nucl Med Sect, Dept Radiol, Med Ctr, Leiden, Netherlands
[3] Vrije Univ Amsterdam Med Ctr, Dept Radiol & Nucl Med, Amsterdam, Netherlands
来源
EJNMMI PHYSICS | 2018年 / 5卷
关键词
F-18-FDG PET/CT; Image reconstruction; PET simulation; Analytical simulation; MONTE-CARLO-SIMULATION; TIME-OF-FLIGHT; POSITRON-EMISSION-TOMOGRAPHY; IMAGE-RECONSTRUCTION; FDG-PET; VALIDATION; GATE; RADIOMICS; DELINEATION; GENERATION;
D O I
10.1186/s40658-018-0215-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Positron-emission tomography (PET) simulators are frequently used for development and performance evaluation of segmentation methods or quantitative uptake metrics. To date, most PET simulation tools are based on Monte Carlo simulations, which are computationally demanding. Other analytical simulation tools lack the implementation of time of flight (TOF) or resolution modelling (RM). In this study, a fast and easy-to-use PET simulation-reconstruction package, SiMulAtion and ReconsTruction (SMART)-PET, is developed and validated, which includes both TOF and RM. SMART-PET, its documentation and instructions to calibrate the tool to a specific PET/CT system are available on Zenodo. SMART-PET allows the fast generation of 3D PET images. As input, it requires one image representing the activity distribution and one representing the corresponding CT image/attenuation map. It allows the user to adjust different parameters, such as reconstruction settings (TOF/RM), noise level or scan duration. Furthermore, a random spatial shift can be included, representing patient repositioning. To evaluate the tool, simulated images were compared with real scan data of the NEMA NU 2 image quality phantom. The scan was acquired as a 60-min list-mode scan and reconstructed with and without TOF and/or RM. For every reconstruction setting, ten statistically equivalent images, representing 30, 60, 120 and 300 s scan duration, were generated. Simulated and real-scan data were compared regarding coefficient of variation in the phantom background and activity recovery coefficients (RCs) of the spheres. Furthermore, standard deviation images of each of the ten statistically equivalent images were compared. Results: SMART-PET produces images comparable to actual phantom data. The image characteristics of simulated and real PET images varied in similar ways as function of reconstruction protocols and noise levels. The change in image noise with variation of simulated TOF settings followed the theoretically expected behaviour. RC as function of sphere size agreed within 0.3-11% between simulated and actual phantom data. Conclusions: SMART-PET allows for rapid and easy simulation of PET data. The user can change various acquisition and reconstruction settings (including RM and TOF) and noise levels. The images obtained show similar image characteristics as those seen in actual phantom data.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] SMART(SiMulAtion and ReconsTruction) PET: An efficient PET simulation-reconstruction tool
    Pfaehler, E.
    Boellaard, R.
    De Jong, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S343 - S344
  • [2] SMART (SiMulAtion and ReconsTruction) PET: an efficient PET simulation-reconstruction tool
    Elisabeth Pfaehler
    Johan R. De Jong
    Rudi A. J. O. Dierckx
    Floris H. P. van Velden
    Ronald Boellaard
    EJNMMI Physics, 5
  • [3] Simulation of Compton reconstruction in liquid xenon PET
    Bryman, Douglas
    Kurchaninov, Leonid
    Lu, Philip
    Retiere, Fabriece
    Sossi, Vesna
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4419 - +
  • [4] Simulation Based Inference for PET Iterative Reconstruction
    Bergere, Bastien
    Dautremer, Thomas
    Comtat, Claude
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2024, PT VII, 2024, 15007 : 625 - 634
  • [5] A SIMULATION STUDY OF IMAGE-RECONSTRUCTION FOR PET
    PAVLOPOULOS, S
    TZANAKOS, G
    BHATIA, M
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 612 - 613
  • [6] The simulation and reconstruction of mixed detector cylinder PET system
    Xu, Hao
    Wang, Shuai
    Shang, Yueying
    Cao, Wencai
    Gao, Min
    Kao, Chien-Min
    Xie, Qingguo
    Xiao, Peng
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [7] Incomplete PET projection data reconstruction method and simulation experiment
    Deng, Z. Z.
    Deng, H. S.
    Hong, W. Y.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (02)
  • [8] A simulation of portable PET with a new geometric image reconstruction method
    Kawatsu, Shoji
    Ushiroya, Noboru
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 445 - 447
  • [9] List mode reconstruction for PET with motion compensation: A simulation study
    Qi, JY
    Huesman, RH
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 413 - 416
  • [10] Development of a Novel Simulation and Image Reconstruction Toolkit for PET and PG Imaging
    Safari, M.
    Zoglauer, A.
    Lovatti, G.
    Anagnostatou, V.
    Nitta, M.
    Tashima, H.
    Thirolf, P.
    Yamaya, T.
    Parodi, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S350 - S350