Air-cooled photovoltaic roof tile as an example of the BIPVT system - An experimental study on the energy and exergy performance

被引:51
|
作者
Wajs, Jan [1 ]
Golabek, Aleksandra [1 ]
Bochniak, Roksana [1 ]
Mikielewicz, Dariusz [1 ]
机构
[1] Gdansk Univ Technol, Fac Mech Engn, Dept Energy & Ind Apparat, Narutowicza 11-12, PL-80233 Gdansk, Poland
关键词
Experimental study; Heat recovery; Photovoltaic roof tile; Solar light simulator; Energy analysis; Exergy analysis; FORCED-CONVECTION;
D O I
10.1016/j.energy.2020.117255
中图分类号
O414.1 [热力学];
学科分类号
摘要
The air-cooled photovoltaic tile is a subject of presented investigations, which focused on improving the overall system efficiency of PV tiles with heat recovery. The operational efficiency of a PV roof tile, together with the construction optimising the air cooling efficiency, were the main points of plans realized at this research stage. The article describes the experimental research consisting of the assessment of electrical, thermal, and total efficiency, as well as exergy efficiency and parameters of a commercial photovoltaic (PV) roof tile, which back wall was cooled by flowing air. An influence of various cooling duct depths and various volumetric flow rates on the system operation was analysed. During the tests, a solar light simulator and a radial fan, providing the assumed volumetric flow rate of cooling air were used. It has been proven that the depth of the cooling duct and the air volumetric flow rate have a crucial impact on the obtained results. Air cooling the back wall of the PV roof tile, lowered the average surface temperature by a maximum of 6.3 K, while the temperature difference, between the surface next to the cooling air inlet and the surface next to its outlet, was a maximum of 23.4 K. Both values were obtained for air cooling with a volumetric flow rate equal to 4 m 3 /h and a channel depth of 25 mm, with a solar irradiance of 900 W/m(2). The overall efficiency was calculated as a sum of the electrical an thermal efficiencies. Its maximal obtained value was about 32%, wherein the highest thermal efficiency was at the level of 27%. An exergy analysis was performed and the exergy efficiency between 5.08% and 9.94% was determined. These results are promising for future utilization of the system consisted of the PV roof tiles together with the cooling ducts. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Effect on the exergy of the PVT system of fins added to an air-cooled channel: A study on temperature and air velocity with ANSYS Fluent
    Ozakin, Ahmet Numan
    Kaya, Ferhat
    SOLAR ENERGY, 2019, 184 : 561 - 569
  • [22] Energy performance of air-cooled chillers with sprayed water on condenser
    Lu, Jian
    Ren, Shengfeng
    Yang, Junlan
    Chang, Ru
    Shen, Zheng
    Yang, Hongxing
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 355 - 362
  • [23] Investigation of an air-cooled double-channel photovoltaic/thermal system with integrated thermal energy storage
    Li, Manfeng
    Lu, Zhaoyang
    Kang, Zhangyang
    Ban, Lijing
    Cong, Hui
    Lu, Yiji
    JOURNAL OF BUILDING ENGINEERING, 2023, 77
  • [24] Performance evaluation of energy efficient evaporatively air-cooled chiller
    Kabeel, A. E.
    El-Samadony, Y. A. F.
    Khiera, M. H.
    APPLIED THERMAL ENGINEERING, 2017, 122 : 204 - 213
  • [25] Experimental study on the evaporative cooling of an air-cooled condenser with humidifying air
    Mao-Yu Wen
    Ching-Yen Ho
    Kuang-Jang Jang
    Cheng-Hsiung Yeh
    Heat and Mass Transfer, 2014, 50 : 225 - 233
  • [26] Experimental study on the evaporative cooling of an air-cooled condenser with humidifying air
    Wen, Mao-Yu
    Ho, Ching-Yen
    Jang, Kuang-
    Yeh, Cheng-Hsiung
    HEAT AND MASS TRANSFER, 2014, 50 (02) : 225 - 233
  • [27] Performance study of a novel indirect evaporative/air-cooled thermoelectric cooling air conditioning system
    Duan, Yujie
    Zhou, Yuanyuan
    Dou, Zhongyu
    Dai, Qiumin
    Yu, Yanshun
    Li, Qiang
    BUILDING AND ENVIRONMENT, 2024, 265
  • [28] Experimental study on heat transfer performance of direct air-cooled condenser in power plant
    Du, Xiao-Ze
    Jin, Yan-Sheng
    Jiang, Jian-Bo
    Yang, Li-Jun
    Yang, Yong-Ping
    Xi, Xin-Ming
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2009, 30 (01): : 99 - 101
  • [29] Analysis of dynamic performance of air-cooled condenser structure system
    Sun, Ying
    Hong, Yan
    PROGRESS IN CIVIL ENGINEERING, PTS 1-4, 2012, 170-173 : 2675 - +
  • [30] Performance study of air-type BIPVT coupled water-cooled wall
    Zhao, Yulong
    Diao, Hongmei
    Zhang, Guoyin
    Ge, Minghui
    ENERGY REPORTS, 2022, 8 : 265 - 270