Air-cooled photovoltaic roof tile as an example of the BIPVT system - An experimental study on the energy and exergy performance

被引:51
|
作者
Wajs, Jan [1 ]
Golabek, Aleksandra [1 ]
Bochniak, Roksana [1 ]
Mikielewicz, Dariusz [1 ]
机构
[1] Gdansk Univ Technol, Fac Mech Engn, Dept Energy & Ind Apparat, Narutowicza 11-12, PL-80233 Gdansk, Poland
关键词
Experimental study; Heat recovery; Photovoltaic roof tile; Solar light simulator; Energy analysis; Exergy analysis; FORCED-CONVECTION;
D O I
10.1016/j.energy.2020.117255
中图分类号
O414.1 [热力学];
学科分类号
摘要
The air-cooled photovoltaic tile is a subject of presented investigations, which focused on improving the overall system efficiency of PV tiles with heat recovery. The operational efficiency of a PV roof tile, together with the construction optimising the air cooling efficiency, were the main points of plans realized at this research stage. The article describes the experimental research consisting of the assessment of electrical, thermal, and total efficiency, as well as exergy efficiency and parameters of a commercial photovoltaic (PV) roof tile, which back wall was cooled by flowing air. An influence of various cooling duct depths and various volumetric flow rates on the system operation was analysed. During the tests, a solar light simulator and a radial fan, providing the assumed volumetric flow rate of cooling air were used. It has been proven that the depth of the cooling duct and the air volumetric flow rate have a crucial impact on the obtained results. Air cooling the back wall of the PV roof tile, lowered the average surface temperature by a maximum of 6.3 K, while the temperature difference, between the surface next to the cooling air inlet and the surface next to its outlet, was a maximum of 23.4 K. Both values were obtained for air cooling with a volumetric flow rate equal to 4 m 3 /h and a channel depth of 25 mm, with a solar irradiance of 900 W/m(2). The overall efficiency was calculated as a sum of the electrical an thermal efficiencies. Its maximal obtained value was about 32%, wherein the highest thermal efficiency was at the level of 27%. An exergy analysis was performed and the exergy efficiency between 5.08% and 9.94% was determined. These results are promising for future utilization of the system consisted of the PV roof tiles together with the cooling ducts. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Experimental study of condensate subcooling with the use of a model of an air-cooled condenser
    Sukhanov V.A.
    Bezukhov A.P.
    Bogov I.A.
    Dontsov N.Y.
    Volkovitsky I.D.
    Tolmachev V.V.
    Thermal Engineering, 2016, 63 (1) : 17 - 23
  • [42] Experimental investigation of the effect of perimeter windscreens on air-cooled condenser fan performance
    Marincowitz, F. S.
    Owen, M. T. F.
    Muiyser, J.
    APPLIED THERMAL ENGINEERING, 2019, 163
  • [43] Performance enhancement of air-cooled chillers with water mist: Experimental and analytical investigation
    Yang, Jia
    Chan, K. T.
    Wu, Xiangsheng
    Yang, Xiaofeng
    Zhang, Hongyu
    APPLIED THERMAL ENGINEERING, 2012, 40 : 114 - 120
  • [44] Experimental investigation of the effects of corona wind on the performance of an air-cooled PV/T
    Golzari, Soudabeh
    Kasaeian, Alibakhsh
    Amidpour, Majid
    Nasirivatan, Shahin
    Mousavi, Soroush
    RENEWABLE ENERGY, 2018, 127 : 284 - 297
  • [45] Performance study of fin structure in air-cooled thermal management system for column power battery
    Han, Peng
    Wang, Jiayun
    Zhao, Xuemin
    Liu, Jiawei
    Wang, Chen
    She, Xiaohui
    JOURNAL OF ENERGY STORAGE, 2024, 104
  • [46] Performance Study of Fin Structure in Air-Cooled Thermal Management System for Column Power Battery
    Han, Peng
    Wang, Jiayun
    Zhao, Xuemin
    Liu, Jiawei
    Wang, Chen
    She, Xiaohui
    SSRN, 2024,
  • [47] Performance study of fin structure in air-cooled thermal management system for column power battery
    Han, Peng
    Wang, Jiayun
    Zhao, Xuemin
    Liu, Jiawei
    Wang, Chen
    She, Xiaohui
    Journal of Energy Storage, 104
  • [48] Optimization of an air-cooled heat sink for cooling of a solar photovoltaic panel: A computational study
    Mankani, Khushbu
    Chaudhry, Hassam Nasarullah
    Calautit, John Kaiser
    ENERGY AND BUILDINGS, 2022, 270
  • [49] COOLING EFFECTIVENESS OF MIST PRECOOLER FOR IMPROVING ENERGY PERFORMANCE OF AIR-COOLED CHILLER
    Yu, Fu Wing
    Chan, Kwok Tai
    Yang, Jia
    Sit, Rachel Kam Yung
    THERMAL SCIENCE, 2018, 22 (01): : 193 - 204
  • [50] Evaporative cooling technologies for air-cooled chillers for building energy performance improvement
    Yu, F. W.
    Chan, K. T.
    Yang, J.
    Sit, R. K. Y.
    ADVANCES IN BUILDING ENERGY RESEARCH, 2016, 10 (01) : 10 - 19