Monte Carlo calculation of scattered radiation from applicators in low energy clinical electron beams

被引:0
|
作者
Jabbari, Nasrollah
Hashemi-Malayeri, Bijan [1 ]
Farajollahi, Ali Reza
Kazemnejad, Anoshiravan
机构
[1] Tarbiat Modares Univ, Dept Med Phys, Tehran, Iran
[2] Tarbiat Modares Univ, Dept Biostat, Tehran, Iran
关键词
Monte Carlo; radiation therapy; medical linear accelerator; electron applicator; scattered radiation; treatment planning;
D O I
暂无
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In radiotherapy with electron beams, scattered radiation from an electron applicator influences the dose distribution in the patient. The contribution of this radiation to the patient dose is significant, even in modern accelerators. In most of radiotherapy treatment planning systems, this component is not explicitly included. In addition, the scattered radiation produced by applicators varies based on the applicator design as well as the field size and distance from the applicators. The aim of this study was to calculate the amount of scattered dose contribution from applicators. We also tried to provide an extensive set of calculated data that could be used as input or benchmark data for advanced treatment planning systems that use Monte Carlo algorithms for dose distribution calculations. Electron beams produced by a NEPTUN 10PC medical linac were modeled using the BEAMnrc system. Central axis depth dose curves of the electron beams were measured and calculated, with and without the applicators in place, for different field sizes and energies. The scattered radiation from the applicators was determined by subtracting the central axis depth dose curves obtained without the applicators from that with the applicator. The results of this study indicated that the scattered radiation from the electron applicators of the NEPTUN 10PC is significant and cannot be neglected in advanced treatment planning systems. Furthermore, our results showed that the scattered radiation depends on the field size and decreases almost linearly with depth.
引用
收藏
页码:97 / 103
页数:7
相关论文
共 50 条
  • [41] MONTE-CARLO CALCULATION OF RADIATION ENERGY ABSORBED IN PLASTIC SCINTILLATORS
    MAINARDI, RT
    BONZI, EV
    RADIATION PHYSICS AND CHEMISTRY, 1995, 45 (05) : 691 - 693
  • [42] Monte Carlo Calculation of the Energy Response Characteristics of a RadFET Radiation Detector
    Belicev, P.
    Jokic, V. Spasic
    Mayer, S.
    Milosevic, M.
    Ilic, R.
    Pesic, M.
    13TH IMEKO TC1-TC7 JOINT SYMPOSIUM - WITHOUT MEASUREMENT NO SCIENCE, WITHOUT SCIENCE NO MEASUREMENT, 2010, 238
  • [43] Monte Carlo modelling of electron beams from medical accelerators
    Ma, CM
    Jiang, SB
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12): : R157 - R189
  • [44] Detailed monte carlo simulation of low energy electron backscattering from solids
    Zhuo, Jun
    Niu, Shengli
    Huang, Liuxing
    Zhu, Jinhui
    Jisuan Wuli/Chinese Journal of Computational Physics, 2009, 26 (04): : 586 - 590
  • [45] Optimizing focused very-high-energy electron beams for radiation therapy based on Monte Carlo simulation
    An, Chaofan
    Zhang, Wei
    Dai, Zeyi
    Li, Jia
    Yang, Xiong
    Wang, Jike
    Nie, Yuancun
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [46] Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm
    Abt. für Medizinische Physik, Univ. Klin. Tübingen, Hoppe-Seyler-Str. 3, 72076 Tübingen, Germany
    Med. Phys., 8 (1466-1475):
  • [47] CLINICAL IMPLEMENTATION OF A MACRO MONTE CARLO ELECTRON DOSE CALCULATION ALGORITHM
    Swinnen, A.
    Petillion, S.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S69 - S70
  • [48] small field electron beams: measurement based validation of the Monte Carlo calculation algorithm
    Pittomvils, G.
    Traneus, E.
    Vanhoutte, F.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1511 - S1512
  • [49] Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm
    Fippel, M
    MEDICAL PHYSICS, 1999, 26 (08) : 1466 - 1475
  • [50] Monte Carlo and experimental investigations of multileaf collimated electron beams for modulated electron radiation therapy
    Lee, MC
    Jiang, SB
    Ma, CM
    MEDICAL PHYSICS, 2000, 27 (12) : 2708 - 2718