Monte Carlo calculation of scattered radiation from applicators in low energy clinical electron beams

被引:0
|
作者
Jabbari, Nasrollah
Hashemi-Malayeri, Bijan [1 ]
Farajollahi, Ali Reza
Kazemnejad, Anoshiravan
机构
[1] Tarbiat Modares Univ, Dept Med Phys, Tehran, Iran
[2] Tarbiat Modares Univ, Dept Biostat, Tehran, Iran
关键词
Monte Carlo; radiation therapy; medical linear accelerator; electron applicator; scattered radiation; treatment planning;
D O I
暂无
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In radiotherapy with electron beams, scattered radiation from an electron applicator influences the dose distribution in the patient. The contribution of this radiation to the patient dose is significant, even in modern accelerators. In most of radiotherapy treatment planning systems, this component is not explicitly included. In addition, the scattered radiation produced by applicators varies based on the applicator design as well as the field size and distance from the applicators. The aim of this study was to calculate the amount of scattered dose contribution from applicators. We also tried to provide an extensive set of calculated data that could be used as input or benchmark data for advanced treatment planning systems that use Monte Carlo algorithms for dose distribution calculations. Electron beams produced by a NEPTUN 10PC medical linac were modeled using the BEAMnrc system. Central axis depth dose curves of the electron beams were measured and calculated, with and without the applicators in place, for different field sizes and energies. The scattered radiation from the applicators was determined by subtracting the central axis depth dose curves obtained without the applicators from that with the applicator. The results of this study indicated that the scattered radiation from the electron applicators of the NEPTUN 10PC is significant and cannot be neglected in advanced treatment planning systems. Furthermore, our results showed that the scattered radiation depends on the field size and decreases almost linearly with depth.
引用
收藏
页码:97 / 103
页数:7
相关论文
共 50 条
  • [21] Monte Carlo variance reduction for energy profile calculation at the electron emission due to photon radiation
    Ueki, Taro
    NUCLEAR SCIENCE AND ENGINEERING, 2007, 157 (02) : 119 - 131
  • [22] MONTE-CARLO ELECTRON-TRANSPORT CALCULATIONS FOR CLINICAL BEAMS USING ENERGY GROUPING
    TENG, SP
    ANDERSON, DW
    LINDSTROM, DG
    APPLIED RADIATION AND ISOTOPES, 1986, 37 (12) : 1189 - 1194
  • [23] Monte Carlo calculation for Intra-Operative Radiotherapy (IOERT) with electron beams
    De Brouwer, T.
    Vandekerkhove, C.
    Simon, S.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S855 - S856
  • [24] ELECTRON BEAMS COMMISSIONING AND VALIDATION OF MONTE CARLO CALCULATION MODULE IN ONCENTRA MASTERPLAN
    Ventura, T.
    Lopes, M. D. C.
    Costa Ferreira, B.
    Neves, A. J.
    Capela, M.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S408 - S408
  • [25] Evaluation of a new commercial Monte Carlo dose calculation algorithm for electron beams
    Vandervoort, Eric J.
    Tchistiakova, Ekaterina
    La Russa, Daniel J.
    Cygler, Joanna E.
    MEDICAL PHYSICS, 2014, 41 (02) : 021711
  • [26] Scattered radiation from radiographic intensifying screen: a Monte Carlo simulation
    Barroso, RC
    Braz, D
    Anjos, MJ
    Lopes, RT
    de Castro, CRF
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS III, 2001, 4508 : 188 - 192
  • [27] Monte Carlo simulation of backscatter from lead for clinical electron beams using EGSnrc
    Chow, James C. L.
    Grigorov, Grigor N.
    MEDICAL PHYSICS, 2008, 35 (04) : 1241 - 1250
  • [28] A THEORY ON LOW-ENERGY ELECTRON-SCATTERING IN SOLIDS AND MONTE-CARLO CALCULATION
    HE, YC
    TAN, ZY
    WANG, XL
    SCIENCE IN CHINA SERIES A-MATHEMATICS PHYSICS ASTRONOMY & TECHNOLOGICAL SCIENCES, 1991, 34 (01): : 94 - 104
  • [29] A THEORY AND MONTE-CARLO CALCULATION ON LOW-ENERGY ELECTRON-SCATTERING IN SOLIDS
    HO, YC
    TAN, ZY
    WANG, XL
    CHEN, JG
    SCANNING MICROSCOPY, 1991, 5 (04) : 945 - 951
  • [30] Monte Carlo simulation for low energy electron transport
    Dubus, A
    PROCEEDINGS OF THE WORKSHOP "MONTE CARLO METHODS AND MODELS FOR APPLICATIONS IN ENERGY AND TECHNOLOGY", 1999, 6266 : 311 - +