Monte Carlo and experimental investigations of multileaf collimated electron beams for modulated electron radiation therapy

被引:55
|
作者
Lee, MC [1 ]
Jiang, SB [1 ]
Ma, CM [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
modulated electron radiation therapy (MERT); IMRT; EGS4 Monte Carlo; multileaf collimator (MLC);
D O I
10.1118/1.1328082
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Modulated electron radiation therapy (MERT) has been proposed as a means of delivering conformal dose to shallow tumors while sparing distal structures and surrounding tissues. Conventional systems for electron beam collimation are labor and time intensive in their construction and are therefore inadequate for use in the sequential delivery of multiple complex fields required by MERT. This study investigates two proposed methods of electron beam collimation: the use of existing photon multileaf collimators (MLC) in a helium atmosphere to reduce in-air electron scatter, and a MLC specifically designed for electron beam collimation. Monte Carlo simulations of a Varian Clinac 2100C were performed using the EGS4/BEAM system and dose calculations performed with the MCDOSE code. Dose penumbras from fields collimated by photon MLCs both with air and with helium at 6, 12, and 20 MeV at a range of SSDs from 70 to 90 cm were examined. Significant improvements were observed for the helium based system. Simulations were also performed on an electron specific MLC located at the level of the last scraper of a 25x25 cm(2) applicator. A number of leaf materials, thicknesses, end shapes, and widths were simulated to determine optimal construction parameters. The results demonstrated that tungsten leaves 15 mm thick and 5 mm wide with unfocused ends would provide sufficient collimation for MERT fields. A prototype electron MLC was constructed and comparisons between film measurements and simulation demonstrate the validity of the Monte Carlo model. Further simulations of dose penumbras demonstrate that such an electron MLC would provide improvements over the helium filled photon MLC at all energies, and improvements in the 90-10 penumbra of 12% to 45% at 20 MeV and 6 MeV, respectively. These improvements were also seen in isodose curves when a complex field shape was simulated. It is thus concluded that an MLC specific for electron beam collimation is required for MERT. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01612-6].
引用
收藏
页码:2708 / 2718
页数:11
相关论文
共 50 条
  • [1] Monte Carlo simulations of electron beams collimated with a dual electron multileaf collimator: A feasibility study
    Inyang S.O.
    Chamberlain A.C.
    Radiological Physics and Technology, 2009, 2 (2) : 210 - 218
  • [2] Monte Carlo investigation of electron beams collimated by an electron-specific MLC for modulated electron radiotherapy
    Eldib, A.
    Jin, L.
    Fan, J.
    Li, J.
    Ma, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2471 - 2471
  • [3] Monte Carlo Modeling of Modulated Electron Beams Delivered Through a Photon Multileaf Collimator
    Tynan, P.
    Stathakis, S.
    Esquivel, C.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [4] Characteristics of electron beams collimated by an electron multileaf collimator
    Jin, L.
    Ma, C.
    ElDib, A.
    Fan, I.
    Lin, T.
    Li, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2643 - 2643
  • [5] A Monte Carlo investigation of fluence profiles collimated by an electron specific MLC during beam delivery for modulated electron radiation therapy
    Deng, J
    Lee, MC
    Ma, CM
    MEDICAL PHYSICS, 2002, 29 (11) : 2472 - 2483
  • [6] An electron specific multileaf collimator for modulated electron radiation therapy
    McNeeley, S
    Li, J
    Price, R
    Chen, L
    Ding, M
    Fourkal, E
    Ma, C
    MEDICAL PHYSICS, 2002, 29 (06) : 1286 - 1286
  • [7] Dosimetric characteristics of an electron multileaf collimator for modulated electron radiation therapy
    Eldib, Ahmed A.
    ElGohary, Mohamed I.
    Fan, Jiajin
    Jin, Lihui
    Li, Jinsheng
    Ma, C-M Charlie
    Elsherbini, Nader A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (02): : 5 - 22
  • [8] Monte Carlo simulations of multileaf collimated electrons
    Lee, MC
    Jiang, SB
    Yi, BY
    Ma, CM
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 176 - 178
  • [9] Monte Carlo source verification of Elekta Synergy for pMLC collimated electron beams
    van Eeden, D.
    du Plessis, F. C. P.
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226
  • [10] Energy and intensity modulated electron radiation therapy by means of a Monte Carlo routine
    Plaza, AL
    Ma, C
    du Plessis, F
    Lagares, J
    Li, J
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S94 - S94