Resonance measurement of capacitance current in ineffectively earthed power systems

被引:0
|
作者
Yi, W. T. [1 ]
Zeng, X. J. [1 ]
Choi, S. S. [2 ]
Liu, Z. L. [1 ]
机构
[1] Changsha Univ Sci & Technol, Sch Elect & Info Engn, Changsha 410077, Hunan, Peoples R China
[2] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
关键词
capacitance current; distribution system; grounding capacitance; grounding fault protection; voltage transformer; resonance measurement;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Capacitance current is an important parameter for single phase ground fault protection and control in ineffectively earthed power systems. A novel method for the capacitance current measurement is presented in the paper. An adjustable reactor is in series connection with the open-delta side of a zero sequence voltage transformer. System resonance frequency is sought by injecting a current signal with variable frequency. By changing the reactor inductance value, another resonance frequency can also be sought The ground capacitance and ground capacitance current can thus be calculated using the two resonance frequencies for the power systems. Experimental work shows that the proposed method has produced results of high precision in real-time, without the need to interrupt power supply.
引用
收藏
页码:1182 / +
页数:2
相关论文
共 50 条
  • [21] Improving the power supply reliability in resonant earthed systems by fault current path control established through Faulted Phase earthing Switch
    Roser, Miran
    Stumberger, Gorazd
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 64 : 714 - 722
  • [22] Constant Current Power Amplifier for MHz Magnetic Resonance Wireless Power Transfer Systems
    Yang, Songnan
    Xiao, Bin
    Shi, Tiefeng
    2017 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2017, : 1046 - 1048
  • [23] REQUIREMENTS FOR CURRENT AND VOLTAGE MEASUREMENT SYSTEMS IN DIRECT CURRENT CONTROLLED INDUSTRIAL POWER INVERTERS
    Schmitt, Maximilian
    Dressel, Bernd
    Ackva, Ansgar
    2015 IEEE 13TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 1ST SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2015,
  • [24] Current pulse method for in situ measurement of electrochemical capacitance
    Snook, Graerne A.
    Urban, Andrew J.
    Lanyon, Marshall R.
    McGregor, Katherine
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 622 (02) : 225 - 232
  • [25] Fault current measurement method for single phase grounding of non-solidly earthed overhead lines
    Shandong University, Jinan 250061, China
    不详
    不详
    不详
    Dianli Xitong Zidonghue, 2008, 9 (74-78):
  • [27] Matching capacitance and transfer efficiency of four wireless power transfer systems via magnetic coupling resonance
    Xiao, Chunyan
    Wei, Kangzheng
    Liu, Fang
    Ma, Yangxiao
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2017, 45 (06) : 811 - 831
  • [28] A study on recovery voltage during capacitive current interruption on high resistance earthed neutral systems
    Yanagi K.
    Toyoda M.
    Koshizuka T.
    IEEJ Transactions on Power and Energy, 2019, 139 (02) : 144 - 149
  • [29] The effects of cable capacitance on longwall power systems
    Novak, T
    Basar, J
    Sottile, J
    Kohler, JL
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (05) : 1406 - 1412
  • [30] The effects of cable capacitance on longwall power systems
    Novak, T
    Basar, J
    Sottile, J
    Kohler, JL
    2003 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-3: CROSSROADS TO INNOVATIONS, 2003, : 1615 - 1621