Resonance measurement of capacitance current in ineffectively earthed power systems

被引:0
|
作者
Yi, W. T. [1 ]
Zeng, X. J. [1 ]
Choi, S. S. [2 ]
Liu, Z. L. [1 ]
机构
[1] Changsha Univ Sci & Technol, Sch Elect & Info Engn, Changsha 410077, Hunan, Peoples R China
[2] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
关键词
capacitance current; distribution system; grounding capacitance; grounding fault protection; voltage transformer; resonance measurement;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Capacitance current is an important parameter for single phase ground fault protection and control in ineffectively earthed power systems. A novel method for the capacitance current measurement is presented in the paper. An adjustable reactor is in series connection with the open-delta side of a zero sequence voltage transformer. System resonance frequency is sought by injecting a current signal with variable frequency. By changing the reactor inductance value, another resonance frequency can also be sought The ground capacitance and ground capacitance current can thus be calculated using the two resonance frequencies for the power systems. Experimental work shows that the proposed method has produced results of high precision in real-time, without the need to interrupt power supply.
引用
收藏
页码:1182 / +
页数:2
相关论文
共 50 条
  • [31] Input and reverse transfer capacitance measurement of MOS-gated power transistors under high current flow
    Deml, C
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2001, 37 (04) : 1062 - 1066
  • [32] Optimal Resonance Reactive Current Shielding Design In Wireless Power Transfer Systems
    Elnail, Kamal Eldin Idris
    Huang, Xueliang
    Tan, Linlin
    PROCEEDINGS OF 2017 CHINA INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC 2017), 2017, : 750 - 753
  • [33] Measurement of Capacitance Current of Neutral Point Non - grounding System
    Liu Hong
    Yu Hua
    Niu Shu
    Guo Ruizhou
    PROCEEDINGS OF 2018 IEEE 3RD ADVANCED INFORMATION TECHNOLOGY, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IAEAC 2018), 2018, : 2393 - 2396
  • [34] A new non-contact approach for fault current measurement of non-solidly earthed overhead lines
    Sun, B. (sunbo@sdu.edu.cn), 1600, Automation of Electric Power Systems Press (36):
  • [35] Factors Affecting Performance of Noninvasive Magnetic Sensors for Current Measurement in Power Systems
    Shrawane, Prasad
    Sidhu, Tarlochan S.
    2022 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2022), 2022,
  • [36] Three channel high dynamic current measurement system for low power systems
    Heller, S.
    Nematollahi, I.
    Koeble, S.
    Woias, P.
    17TH INTERNATIONAL CONFERENCE ON MICRO AND NANOTECHNOLOGY FOR POWER GENERATION AND ENERGY CONVERSION APPLICATIONS (POWERMEMS 2017), 2018, 1052
  • [37] Research on Inductance–capacitance electromagnetic resonance measurement of prestressed concrete beam
    Cui, Hongmei
    Li, Xingxing
    Zhang, Benniu
    Yuan, Feiyun
    Chen, Bo
    Measurement: Journal of the International Measurement Confederation, 2022, 189
  • [38] High precision methods for online measurement of capacitance in power capacitors
    Fuhrmann, Henning
    Bengtsson, Tord
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1141 - 1144
  • [39] The measurement of the power factor and capacitance of a condenser by comparison with a mutual inductance
    Smith, AW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1933, 4 (05): : 280 - 284
  • [40] Research on a method of fault line selection for single-phase earth fault in ineffectively grounded power systems
    Lu, Gai-Feng
    Hua, Yu
    Jin, Xiao-Bing
    Ren, Zhi-Qiang
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (12): : 44 - 49