The recovery voltages between contacts of circuit-breaker during capacitive current interruption on overhead transmission lines with high resistance neutral system were investigated. Conditions were clarified which are to be equivalent on recovery voltage level between high resistance neutral system and effectively earthed neutral system using single line and double line systems. The conditions are tentatively indicated as less than 100 km of line length and less than 1 kilo ohms of neutral resistance. © 2019 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:144 / 149
页数:5
相关论文
共 50 条
  • [1] TRV (Transient Recovery Voltage) in High Voltage Current Interruption
    Das, J. C.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (02) : 2165 - 2172
  • [2] Capacitive Current Interruption With Air-Break High Voltage Disconnectors
    Chai, Yajing
    Wouters, P. A. A. F.
    van Hoppe, R. T. W. J.
    Smeets, R. P. P.
    Peelo, D. F.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (02) : 762 - 769
  • [3] INTERRUPTION OF LOW INDUCTIVE AND CAPACITIVE CURRENTS IN HIGH-VOLTAGE SYSTEMS
    KOPAINSKY, J
    RUOSS, E
    BROWN BOVERI REVIEW, 1979, 66 (04): : 255 - 261
  • [4] Experiments on Capacitive Current Interruption with Air-break High Voltage Disconnectors
    Chai, Y.
    Wouters, P. A. A. F.
    van Hoppe, R. T. W. J.
    Smeets, R. P. P.
    Peelo, D. F.
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 4024 - +
  • [5] A Novel Measurement Device of Capacitive Current for Ineffectively Earthed Distribution Systems
    Liu Zhanglei
    Zeng Xiangjun
    Jin Wangyi
    Yi Wentao
    Xu Yao
    2008 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-5, 2008, : 1682 - 1685
  • [6] Voltage analysis of high resistance earthed fault in non-solidly grounded systems
    Zhang, X. H.
    Pan, Z. C.
    Xu, B. Y.
    Ha, H. X.
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 813 - 816
  • [7] APPLYING HIGH RESISTANCE NEUTRAL GROUNDING IN MEDIUM VOLTAGE SYSTEMS
    Kingrey, Lawrence J.
    Painter, Ralph
    Locker, Anthony S.
    2010 RECORD OF CONFERENCE PAPERS INDUSTRY APPLICATIONS SOCIETY 57TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE PCIC, 2010,
  • [8] Interruption of Direct Current at High-Voltage.
    Allaart, A.J.
    Elektrotechniek, 1985, 63 (09): : 905 - 919
  • [9] The Voltage Distribution Characteristics of a Hybrid Circuit Breaker During High Current Interruption
    程显
    段雄英
    廖敏夫
    黄智慧
    罗彦
    邹积岩
    Plasma Science and Technology, 2013, (08) : 800 - 806
  • [10] The Voltage Distribution Characteristics of a Hybrid Circuit Breaker During High Current Interruption
    程显
    段雄英
    廖敏夫
    黄智慧
    罗彦
    邹积岩
    Plasma Science and Technology, 2013, 15 (08) : 800 - 806