A 6 DoF, Wearable, Compliant Shoe Sensor for Total Ground Reaction Measurement

被引:15
|
作者
Eng, Stephanie [1 ]
Al-Mai, Osama [1 ]
Ahmadi, Mojtaba [1 ]
机构
[1] Carleton Univ, Dept Mech & Aerosp Engn, Ottawa, ON K1S 5B6, Canada
关键词
Calibration; force measurement; force sensors; pressure measurement; sensor systems and applications; sensors; sensors systems; PLANTAR PRESSURE MEASUREMENT; REACTION FORCE; MEASUREMENT SYSTEM; BALANCE ASSESSMENT; FREQUENCY CONTENT; OLDER-ADULTS; GAIT; CALIBRATION; FALLS;
D O I
10.1109/TIM.2018.2829338
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we present a compliant six-axis sensor for total ground reaction measurement, the calibration methodology, and preliminary data. The sensor is intended for gait analysis and is designed to have minimal effect on natural gait. A triaxial optical force sensor is combined with an array of pressure sensing films to form a wearable compliant six-axis force/moment sensor. Two sensor units were developed for the toe and heel and used in two types of experiments: stepping on the sensors that are mounted on the ground and attaching the sensors under the shoe while walking. The data from the sensors are compared with measurements obtained from a standard force plate. The deflections induced by the sensor compliance exhibit a slight nonlinear force-deflection relation. Regardless of the nonlinear effects, the sensor is accurately calibrated with a linear least squares method. To see how well these nonlinearities could be calibrated for, a nonlinear calibration with a neural network was used. For the sensors attached to the floor, a linear calibration achieved an RMSE of 4.49% while the neural network achieves 2.68%. For the wearable sensor, the linear calibration RMSE was 9.39% and the neural network RMSE was 5.21%. When the orientation data of the sensors (measured by a motion capture system) were added as an input to the neural network calibration, the RMSE was reduced to 3.25%.
引用
收藏
页码:2714 / 2722
页数:9
相关论文
共 43 条
  • [1] Wearable force sensor with parallel structure for measurement of ground-reaction force
    Liu, Tao
    Inoue, Yoshio
    Shibata, Kyoko
    MEASUREMENT, 2007, 40 (06) : 644 - 653
  • [2] Validation of a wireless shoe insole for ground reaction force measurement
    Burns, Geoffrey T.
    Zendler, Jessica Deneweth
    Zernicke, Ronald F.
    JOURNAL OF SPORTS SCIENCES, 2019, 37 (10) : 1129 - 1138
  • [3] Measurement of human lower limb orientations and ground reaction forces using wearable sensor systems
    Liu, Tao
    Inoue, Yoshio
    Shibata, Kyoko
    Zheng, Rencheng
    2007 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS, VOLS 1-3, 2007, : 524 - 529
  • [4] A Wearable Ground Reaction Force Sensor System and Its Application to the Measurement of Extrinsic Gait Variability
    Liu, Tao
    Inoue, Yoshio
    Shibata, Kyoko
    SENSORS, 2010, 10 (11) : 10240 - 10255
  • [5] A tele-monitoring system for gait rehabilitation with an inertial measurement unit and a shoe-type ground reaction force sensor
    Bae, Joonbum
    Tomizuka, Masayoshi
    MECHATRONICS, 2013, 23 (06) : 646 - 651
  • [6] Measurement Science for 6DOF Object Pose Ground Truth
    Eastman, Roger D.
    Marvel, Jeremy
    Falco, Joseph
    Hong, Tsai
    2013 IEEE INTERNATIONAL SYMPOSIUM ON ROBOTIC AND SENSORS ENVIRONMENTS (ROSE 2013), 2013,
  • [7] THREE-DOF ORIENTATION MEASUREMENT BASED ON OPTICAL SENSOR FOR REACTION SPHERE
    Liu, Guanghui
    Sun, Fei
    Zhou, Jun
    Guo, Jianguo
    FOURTH IAA CONFERENCE ON DYNAMICS AND CONTROL OF SPACE SYSTEMS 2018, PTS I-III, 2018, 165 : 2095 - 2105
  • [8] Ground reaction forces don’t indicate tibial forces: implications for injury prevention, shoe design & wearable tech
    Matijevich E.
    Branscombe L.M.
    Scott L.R.
    Zelik K.
    Footwear Science, 2019, 11 (sup1): : S70 - S72
  • [9] New Method for Assessment of Gait Variability Based on Wearable Ground Reaction Force Sensor
    Liu, Tao
    Inoue, Yoshio
    Shibata, Kyoko
    2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-8, 2008, : 2341 - 2344
  • [10] Measurement of ground reaction forces in cats after total hip replacement
    Schweng, Gregor
    Bockstahler, Barbara
    Tichy, Alexander
    Zahn, Klaus
    Haimel, Georg
    Schwarz, Guenter
    Schnabl-Feichter, Eva
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2024, 26 (12)