A 6 DoF, Wearable, Compliant Shoe Sensor for Total Ground Reaction Measurement

被引:15
|
作者
Eng, Stephanie [1 ]
Al-Mai, Osama [1 ]
Ahmadi, Mojtaba [1 ]
机构
[1] Carleton Univ, Dept Mech & Aerosp Engn, Ottawa, ON K1S 5B6, Canada
关键词
Calibration; force measurement; force sensors; pressure measurement; sensor systems and applications; sensors; sensors systems; PLANTAR PRESSURE MEASUREMENT; REACTION FORCE; MEASUREMENT SYSTEM; BALANCE ASSESSMENT; FREQUENCY CONTENT; OLDER-ADULTS; GAIT; CALIBRATION; FALLS;
D O I
10.1109/TIM.2018.2829338
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we present a compliant six-axis sensor for total ground reaction measurement, the calibration methodology, and preliminary data. The sensor is intended for gait analysis and is designed to have minimal effect on natural gait. A triaxial optical force sensor is combined with an array of pressure sensing films to form a wearable compliant six-axis force/moment sensor. Two sensor units were developed for the toe and heel and used in two types of experiments: stepping on the sensors that are mounted on the ground and attaching the sensors under the shoe while walking. The data from the sensors are compared with measurements obtained from a standard force plate. The deflections induced by the sensor compliance exhibit a slight nonlinear force-deflection relation. Regardless of the nonlinear effects, the sensor is accurately calibrated with a linear least squares method. To see how well these nonlinearities could be calibrated for, a nonlinear calibration with a neural network was used. For the sensors attached to the floor, a linear calibration achieved an RMSE of 4.49% while the neural network achieves 2.68%. For the wearable sensor, the linear calibration RMSE was 9.39% and the neural network RMSE was 5.21%. When the orientation data of the sensors (measured by a motion capture system) were added as an input to the neural network calibration, the RMSE was reduced to 3.25%.
引用
收藏
页码:2714 / 2722
页数:9
相关论文
共 43 条
  • [21] Sensor fusion of robotic total station and inertial navigation system for 6DoF tracking applications
    Thalmann, Tomas
    Neuner, Hans
    APPLIED GEOMATICS, 2024, 16 (04) : 933 - 949
  • [22] Validity and Reliability of the Insole3 Instrumented Shoe Insole for Ground Reaction Force Measurement during Walking and Running
    Cramer, Leora A.
    Wimmer, Markus A.
    Malloy, Philip
    O'Keefe, Joan A.
    Knowlton, Christopher B.
    Ferrigno, Christopher
    SENSORS, 2022, 22 (06)
  • [23] A New Proxy Measurement Algorithm with Application to the Estimation of Vertical Ground Reaction Forces Using Wearable Sensors
    Guo, Yuzhu
    Storm, Fabio
    Zhao, Yifan
    Billings, Stephen A.
    Pavic, Aleksandar
    Mazza, Claudia
    Guo, Ling-Zhong
    SENSORS, 2017, 17 (10)
  • [24] A 6DOF pose measurement method for metal casts object based on stereo vision sensor
    Wan, Guoyang
    Hu, Yaocong
    Liu, Bingyou
    Bai, Shoujun
    Xing, Kaisheng
    Tao, Xiuwen
    SENSOR REVIEW, 2024, 44 (01) : 22 - 34
  • [25] Comparing the Ground Reaction Forces, Toe Clearances, and Stride Lengths of Young and Older Adults Using a Novel Shoe Sensor System
    Matsumoto, Hide
    Tomosada, Masaki
    Nishi, Toshiaki
    Sasaki, Yoshihiro
    Sakurai, Ryota
    Yamaguchi, Takeshi
    SENSORS, 2024, 24 (21)
  • [26] Prediction of Three-Directional Ground Reaction Forces during Walking Using a Shoe Sole Sensor System and Machine Learning
    Yamaguchi, Takeshi
    Takahashi, Yuya
    Sasaki, Yoshihiro
    SENSORS, 2023, 23 (21)
  • [27] Three-Axis Sensor Development for Ground Reaction Forces Measurement with Sports Applications
    Moscoso, Renzo
    Callupe, Rocio
    Garcia, Jose
    Villota, Elizabeth R.
    PROCEEDINGS OF THE 7TH BRAZILIAN TECHNOLOGY SYMPOSIUM (BTSYM'21): EMERGING TRENDS IN SYSTEMS ENGINEERING MATHEMATICS AND PHYSICAL SCIENCES, VOL 2, 2022, 295 : 672 - 679
  • [28] An Efficient Calibration Method for a Novel 6-DOF Acceleration Sensor System and Application to Measurement of a Vehicle Motion
    Onodera, Ryoji
    Mimura, Nobuharu
    Shishido, Michiaki
    2010 IEEE SENSORS, 2010, : 600 - 605
  • [29] Measurement of ground reaction forces after total hip arthroplasty using different surgical approaches
    Leuchte, S.
    Luchs, A.
    Wohlrab, D.
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2007, 145 (01): : 74 - 80
  • [30] Real-Life Measurement of Tri-Axial Walking Ground Reaction Forces Using Optimal Network of Wearable Inertial Measurement Units
    Shahabpoor, Erfan
    Pavic, Aleksandar
    Brownjohn, James M. W.
    Billings, Stephen A.
    Guo, Ling-Zhong
    Bocian, Mateusz
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2018, 26 (06) : 1243 - 1253