A 6 DoF, Wearable, Compliant Shoe Sensor for Total Ground Reaction Measurement

被引:15
|
作者
Eng, Stephanie [1 ]
Al-Mai, Osama [1 ]
Ahmadi, Mojtaba [1 ]
机构
[1] Carleton Univ, Dept Mech & Aerosp Engn, Ottawa, ON K1S 5B6, Canada
关键词
Calibration; force measurement; force sensors; pressure measurement; sensor systems and applications; sensors; sensors systems; PLANTAR PRESSURE MEASUREMENT; REACTION FORCE; MEASUREMENT SYSTEM; BALANCE ASSESSMENT; FREQUENCY CONTENT; OLDER-ADULTS; GAIT; CALIBRATION; FALLS;
D O I
10.1109/TIM.2018.2829338
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we present a compliant six-axis sensor for total ground reaction measurement, the calibration methodology, and preliminary data. The sensor is intended for gait analysis and is designed to have minimal effect on natural gait. A triaxial optical force sensor is combined with an array of pressure sensing films to form a wearable compliant six-axis force/moment sensor. Two sensor units were developed for the toe and heel and used in two types of experiments: stepping on the sensors that are mounted on the ground and attaching the sensors under the shoe while walking. The data from the sensors are compared with measurements obtained from a standard force plate. The deflections induced by the sensor compliance exhibit a slight nonlinear force-deflection relation. Regardless of the nonlinear effects, the sensor is accurately calibrated with a linear least squares method. To see how well these nonlinearities could be calibrated for, a nonlinear calibration with a neural network was used. For the sensors attached to the floor, a linear calibration achieved an RMSE of 4.49% while the neural network achieves 2.68%. For the wearable sensor, the linear calibration RMSE was 9.39% and the neural network RMSE was 5.21%. When the orientation data of the sensors (measured by a motion capture system) were added as an input to the neural network calibration, the RMSE was reduced to 3.25%.
引用
收藏
页码:2714 / 2722
页数:9
相关论文
共 43 条
  • [41] Relationship Between Vertical Ground Reaction Force and Acceleration from Wearable Inertial Measurement Units During Single-Leg Drop Landing After Anterior Cruciate Ligament Reconstruction
    Suzuki, Makoto
    Ishida, Tomoya
    Matsumoto, Hisashi
    Kondo, Kenichiro
    Yamaguchi, Shota
    Kaneko, Satoru
    Inoue, Chiharu
    Aoki, Yoshimitsu
    Tohyama, Harukazu
    Samukawa, Mina
    APPLIED SCIENCES-BASEL, 2025, 15 (03):
  • [42] Total reaction cross sections measurement for 6,8He and 8,9Li nuclei with energies of (25–45)/A MeV on natAl and natPb
    Erdemchimeg B.
    Artukh A.G.
    Davaa S.
    Klygin S.A.
    Kononenko G.A.
    Khuukhenkhuu G.
    Kyslukha D.A.
    Lukyanov S.M.
    Mikhailova T.I.
    Sereda Y.M.
    Penionzhkevich Y.E.
    Vorontzov A.N.
    Borcea C.
    Rotaru F.
    Stanoiu M.
    Bulletin of the Russian Academy of Sciences: Physics, 2016, 80 (3) : 223 - 226
  • [43] Personal Inertial Navigation System Employing MEMS Wearable Ground Reaction Sensor Array and Interface ASIC Achieving a Position Accuracy of 5.5m Over 3km Walking Distance Without GPS
    Guo, Qingbo
    Deng, William
    Bebek, Ozkan
    Cavusoglu, Cenk
    Mastrangelo, Carlos
    Young, Darrin
    2018 IEEE INTERNATIONAL SOLID-STATE CIRCUITS CONFERENCE - (ISSCC), 2018, : 180 - +