Biomechanical comparison of four different fixation methods in the management of Pauwels type III femoral neck fractures: Is there a clear winner?

被引:8
|
作者
Yildirim, Cem [1 ]
Demirel, Mehmet [2 ]
Karahan, Goekhan [1 ]
Cetinkaya, Engin [3 ]
Misir, Abduelhamit [4 ]
Yamak, Fatih [5 ]
Bozdag, Erguen [5 ]
机构
[1] Univ Hlth Sci, Basaksehir Cam & Sakura City Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[2] Istanbul Univ, Istanbul Sch Med, Dept Orthoped & Traumatol, Istanbul, Turkey
[3] Bahcesehir Univ, Medicalpark Goztepe Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[4] Medicana Int Istanbul Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[5] Istanbul Tech Univ, Fac Mech Engn Strength Mat & Biomech, Istanbul, Turkey
关键词
Pauwels type III femoral neck fractures; Cannulated screws; Medial buttress plate; Inverted triangle configuration; Distal unicortical; Distal bicortical screw placement; MEDIAL BUTTRESS PLATE; CANNULATED SCREW; INTRACAPSULAR FRACTURES; HIP SCREW;
D O I
10.1016/j.injury.2022.06.029
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Cannulated screws augmented with the medial buttress plate could confer greater biomechanical stability and higher union rates than the screw fixation alone for treating young patients with Pauwels type III femoral neck fractures (FNFs). No study has evaluated the effects of distal bicortical screw fixation and biomechanical properties of buttress plate augmentation under simultaneous vertical and rotational forces, physiologically acting on the hip joint. This study aimed to compare the biomechanical properties of four methods of three cannulated screw fixation under the combined axial and torsional loading in a synthetic femur model of type III FNF.Methods: Twenty-four third-generation composite femora were divided into four groups (6 femora in each group) based on the screw fixation configuration: inverted triangle configuration ( Group A ), Pauwels' configuration ( Group B ), inverted triangle configuration combined with medial buttress plate using distal unicortical ( Group C ), and distal bicortical screw placement ( Group D ). A Pauwels type III FNF was simulated on the sawbones. Each model was subjected to the combined axial and torsional cyclic loading and subsequently tested to failure.Result: Significant differences were determined in axial stiffness (AS) among the four groups ( p = 0.024), whereas there was no significant difference in torsional stiffness ( p = 0.147). The mean AS was higher in group D (639.5 +/- 86.2 N/mm) than in group A (430.6 +/- 94.8 N/mm), group B (426.2 +/- 41.9 N/mm), and group C (451.2 +/- 156.7 N/mm). Failure forces (FFs) were significantly different among four groups ( p = 0.007), while there was no considerable difference in failure moment values ( p = 0.555). The mean FF was significantly higher in group D (1307.1 +/- 96.4 N) than in group A (1076.9 +/- 371.2 N) and group B (1075.5 +/- 348.3 N) ( p = 0.014 and p = 0.018, respectively). There was no significant difference in the mean FF between groups D and C.Conclusion: Regardless of the medial plate use, multiple cannulated systems could provide similar biomechanical results regarding torsional stiffness and failure moments. Bicortical placement of the most distal screw in medial buttress plate application could improve axial stability but not significantly affect the rotational stability of the inverted triangle screw fixation system in managing type III FNFs.(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3124 / 3129
页数:6
相关论文
共 50 条
  • [1] Biomechanical Evaluation of Internal Fixation of Pauwels Type III Femoral Neck Fractures: A Systematic Review of Various Fixation Methods
    Cha, Yong-Han
    Yoo, Jun-Il
    Hwang, Seok-Young
    Kim, Kap-Jung
    Kim, Ha-Yong
    Choy, Won-Sik
    Hwang, Sun-Chul
    CLINICS IN ORTHOPEDIC SURGERY, 2019, 11 (01) : 1 - 14
  • [2] Biomechanical analysis of two medial buttress plate fixation methods to treat Pauwels type III femoral neck fractures
    Jichao Liu
    Zhengwei Li
    Jie Ding
    Bingzhe Huang
    Chengdong Piao
    BMC Musculoskeletal Disorders, 23
  • [3] Biomechanical analysis of two medial buttress plate fixation methods to treat Pauwels type III femoral neck fractures
    Liu, Jichao
    Li, Zhengwei
    Ding, Jie
    Huang, Bingzhe
    Piao, Chengdong
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [4] Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: A biomechanical study
    Zhou, Lin
    Lin, Jiaming
    Huang, Anfei
    Gan, Weidong
    Zhai, Xu
    Sun, Kai
    Huang, Shiqing
    Li, Zhizhong
    CLINICAL BIOMECHANICS, 2020, 74 : 103 - 110
  • [5] Biomechanical study of internal fixation methods for femoral neck fractures based on Pauwels angle
    Wang, Fuyang
    Liu, Yuchen
    Huo, Yi
    Wang, Ziming
    Zhang, Jinge
    Xu, Minghao
    Ma, Kaiming
    Wang, Linbao
    Lu, Yongtao
    Cheng, Liangliang
    Zhao, Dewei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [6] Biomechanical evaluation of different internal fixation methods based on finite element analysis for Pauwels type III femoral neck fracture
    Jiang, Xianbao
    Liang, Ke
    Du, Gang
    Chen, Yuan
    Tang, Yu
    Geng, Kuihua
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (10): : 3115 - 3123
  • [7] Finite element analysis of the Femoral neck system for different placement positions in the fixation of Pauwels type III femoral neck fractures
    Zhu, Yongjia
    Wu, Shuai
    Yan, Jiapeng
    Wang, Wenhong
    Huang, Xiao
    Zhang, Hongfei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2025, 56 (04):
  • [8] Biomechanical evaluation of percutaneous compression plate and femoral neck system in Pauwels type III femoral neck fractures
    Xie, Xiaoping
    Bi, Songqi
    Song, Qingxu
    Zhang, Qiong
    Yan, Zhixing
    Zhou, Xiaoyang
    Yu, Tiecheng
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2024, 25 (01)
  • [9] Finite element comparative analysis of three different internal fixation methods in the treatment of Pauwels type III femoral neck fractures
    Ma, Ji
    Zhao, Ziying
    Zhi, Xiaodong
    Wang, Hao
    Wang, Wei
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [10] Finite element comparative analysis of three different internal fixation methods in the treatment of Pauwels type III femoral neck fractures
    Ji Ma
    Ziying Zhao
    Xiaodong Zhi
    Hao Wang
    Wei Wang
    BMC Musculoskeletal Disorders, 23