Biomechanical comparison of four different fixation methods in the management of Pauwels type III femoral neck fractures: Is there a clear winner?

被引:8
|
作者
Yildirim, Cem [1 ]
Demirel, Mehmet [2 ]
Karahan, Goekhan [1 ]
Cetinkaya, Engin [3 ]
Misir, Abduelhamit [4 ]
Yamak, Fatih [5 ]
Bozdag, Erguen [5 ]
机构
[1] Univ Hlth Sci, Basaksehir Cam & Sakura City Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[2] Istanbul Univ, Istanbul Sch Med, Dept Orthoped & Traumatol, Istanbul, Turkey
[3] Bahcesehir Univ, Medicalpark Goztepe Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[4] Medicana Int Istanbul Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[5] Istanbul Tech Univ, Fac Mech Engn Strength Mat & Biomech, Istanbul, Turkey
关键词
Pauwels type III femoral neck fractures; Cannulated screws; Medial buttress plate; Inverted triangle configuration; Distal unicortical; Distal bicortical screw placement; MEDIAL BUTTRESS PLATE; CANNULATED SCREW; INTRACAPSULAR FRACTURES; HIP SCREW;
D O I
10.1016/j.injury.2022.06.029
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Cannulated screws augmented with the medial buttress plate could confer greater biomechanical stability and higher union rates than the screw fixation alone for treating young patients with Pauwels type III femoral neck fractures (FNFs). No study has evaluated the effects of distal bicortical screw fixation and biomechanical properties of buttress plate augmentation under simultaneous vertical and rotational forces, physiologically acting on the hip joint. This study aimed to compare the biomechanical properties of four methods of three cannulated screw fixation under the combined axial and torsional loading in a synthetic femur model of type III FNF.Methods: Twenty-four third-generation composite femora were divided into four groups (6 femora in each group) based on the screw fixation configuration: inverted triangle configuration ( Group A ), Pauwels' configuration ( Group B ), inverted triangle configuration combined with medial buttress plate using distal unicortical ( Group C ), and distal bicortical screw placement ( Group D ). A Pauwels type III FNF was simulated on the sawbones. Each model was subjected to the combined axial and torsional cyclic loading and subsequently tested to failure.Result: Significant differences were determined in axial stiffness (AS) among the four groups ( p = 0.024), whereas there was no significant difference in torsional stiffness ( p = 0.147). The mean AS was higher in group D (639.5 +/- 86.2 N/mm) than in group A (430.6 +/- 94.8 N/mm), group B (426.2 +/- 41.9 N/mm), and group C (451.2 +/- 156.7 N/mm). Failure forces (FFs) were significantly different among four groups ( p = 0.007), while there was no considerable difference in failure moment values ( p = 0.555). The mean FF was significantly higher in group D (1307.1 +/- 96.4 N) than in group A (1076.9 +/- 371.2 N) and group B (1075.5 +/- 348.3 N) ( p = 0.014 and p = 0.018, respectively). There was no significant difference in the mean FF between groups D and C.Conclusion: Regardless of the medial plate use, multiple cannulated systems could provide similar biomechanical results regarding torsional stiffness and failure moments. Bicortical placement of the most distal screw in medial buttress plate application could improve axial stability but not significantly affect the rotational stability of the inverted triangle screw fixation system in managing type III FNFs.(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3124 / 3129
页数:6
相关论文
共 50 条
  • [21] Internal fixation system with the pyramid screw head for the treatment of Pauwels type III femoral neck fractures
    Wang, Songyuan
    Deng, Xuan
    Zhong, Hao
    Ma, Lei
    Wang, Xiyu
    Lou, Xinqi
    Fan, Xuanze
    Duan, Wangping
    Zhang, Kai
    Li, Pengcui
    Wei, Xiaochun
    Zhao, Yongwang
    Wang, Yanqin
    Wu, Xiaogang
    Xue, Yanru
    Chen, Weiyi
    ACTA MECHANICA SINICA, 2023, 39 (08)
  • [22] A biomechanical comparison of four different fixation methods for midshaft clavicle fractures
    Chen, Yang
    Yang, Yang
    Ma, Xinlong
    Xu, Weiguo
    Ma, Jianxiong
    Zhu, Shaowen
    Ma, Baoyi
    Xing, Dan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (01) : 13 - 19
  • [23] Fracture morphology and biomechanical characteristics of Pauwels III femoral neck fractures in young adults
    Wang, Kaiyang
    Ni, Ming
    Liao, Peng
    Dou, Bang
    Yan, Xu
    Lv, Lin
    Zhang, Fangfang
    Mei, Jiong
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (11): : 3227 - 3238
  • [24] Comparative finite element analysis of four different internal fixation implants for Pauwels type III femoral neck fractures in various fracture angles in the sagittal plane
    Ozer, Alaettin
    Oner, Kerim
    Okutan, Ahmet Emin
    Ayas, Muhammet Salih
    JOINT DISEASES AND RELATED SURGERY, 2022, 33 (02): : 352 - 358
  • [25] Screw-blade fixation systems in Pauwels three femoral neck fractures: a biomechanical evaluation
    Matthias Knobe
    Simon Altgassen
    Klaus-Jürgen Maier
    Gertraud Gradl-Dietsch
    Chris Kaczmarek
    Sven Nebelung
    Kajetan Klos
    Bong-Sung Kim
    Boyko Gueorguiev
    Klemens Horst
    Benjamin Buecking
    International Orthopaedics, 2018, 42 : 409 - 418
  • [26] Screw-blade fixation systems in Pauwels three femoral neck fractures: a biomechanical evaluation
    Knobe, Matthias
    Altgassen, Simon
    Maier, Klaus-Jurgen
    Gradl-Dietsch, Gertraud
    Kaczmarek, Chris
    Nebelung, Sven
    Klos, Kajetan
    Kim, Bong-Sung
    Gueorguiev, Boyko
    Horst, Klemens
    Buecking, Benjamin
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (02) : 409 - 418
  • [27] In vitro biomechanical comparison of three methods for internal fixation of femoral neck fractures in dogs
    Fisher, S. C.
    McLaughlin, R. M.
    Elder, S. H.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2012, 25 (01) : 36 - 41
  • [28] Biomechanical Evaluation of Cannulated Screw Optimization for Stabilization of Pauwels Type Femoral Neck Fractures
    Verim, Ozgur
    APPLIED SCIENCES-BASEL, 2024, 14 (07):
  • [29] Evaluation of full thread screw and different fixation configurations in Pauwels type III femoral neck fracture
    Qiu, Jianjun
    Zou, Hanlin
    Zhang, Lei
    Zhou, Xu
    HELIYON, 2023, 9 (11)
  • [30] Results of Internal Fixation of Pauwels Type-3 Vertical Femoral Neck Fractures
    Parker, Martyn J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (02): : 490 - 491