Biomechanical comparison of four different fixation methods in the management of Pauwels type III femoral neck fractures: Is there a clear winner?

被引:8
|
作者
Yildirim, Cem [1 ]
Demirel, Mehmet [2 ]
Karahan, Goekhan [1 ]
Cetinkaya, Engin [3 ]
Misir, Abduelhamit [4 ]
Yamak, Fatih [5 ]
Bozdag, Erguen [5 ]
机构
[1] Univ Hlth Sci, Basaksehir Cam & Sakura City Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[2] Istanbul Univ, Istanbul Sch Med, Dept Orthoped & Traumatol, Istanbul, Turkey
[3] Bahcesehir Univ, Medicalpark Goztepe Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[4] Medicana Int Istanbul Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[5] Istanbul Tech Univ, Fac Mech Engn Strength Mat & Biomech, Istanbul, Turkey
关键词
Pauwels type III femoral neck fractures; Cannulated screws; Medial buttress plate; Inverted triangle configuration; Distal unicortical; Distal bicortical screw placement; MEDIAL BUTTRESS PLATE; CANNULATED SCREW; INTRACAPSULAR FRACTURES; HIP SCREW;
D O I
10.1016/j.injury.2022.06.029
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Cannulated screws augmented with the medial buttress plate could confer greater biomechanical stability and higher union rates than the screw fixation alone for treating young patients with Pauwels type III femoral neck fractures (FNFs). No study has evaluated the effects of distal bicortical screw fixation and biomechanical properties of buttress plate augmentation under simultaneous vertical and rotational forces, physiologically acting on the hip joint. This study aimed to compare the biomechanical properties of four methods of three cannulated screw fixation under the combined axial and torsional loading in a synthetic femur model of type III FNF.Methods: Twenty-four third-generation composite femora were divided into four groups (6 femora in each group) based on the screw fixation configuration: inverted triangle configuration ( Group A ), Pauwels' configuration ( Group B ), inverted triangle configuration combined with medial buttress plate using distal unicortical ( Group C ), and distal bicortical screw placement ( Group D ). A Pauwels type III FNF was simulated on the sawbones. Each model was subjected to the combined axial and torsional cyclic loading and subsequently tested to failure.Result: Significant differences were determined in axial stiffness (AS) among the four groups ( p = 0.024), whereas there was no significant difference in torsional stiffness ( p = 0.147). The mean AS was higher in group D (639.5 +/- 86.2 N/mm) than in group A (430.6 +/- 94.8 N/mm), group B (426.2 +/- 41.9 N/mm), and group C (451.2 +/- 156.7 N/mm). Failure forces (FFs) were significantly different among four groups ( p = 0.007), while there was no considerable difference in failure moment values ( p = 0.555). The mean FF was significantly higher in group D (1307.1 +/- 96.4 N) than in group A (1076.9 +/- 371.2 N) and group B (1075.5 +/- 348.3 N) ( p = 0.014 and p = 0.018, respectively). There was no significant difference in the mean FF between groups D and C.Conclusion: Regardless of the medial plate use, multiple cannulated systems could provide similar biomechanical results regarding torsional stiffness and failure moments. Bicortical placement of the most distal screw in medial buttress plate application could improve axial stability but not significantly affect the rotational stability of the inverted triangle screw fixation system in managing type III FNFs.(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3124 / 3129
页数:6
相关论文
共 50 条
  • [31] Results of internal fixation of Pauwels type-3 vertical femoral neck fractures
    Liporace, Frank
    Gaines, Robert
    Collinge, Cory
    Haidukewych, George J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (08): : 1654 - 1659
  • [32] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Zheng Wang
    Yong Yang
    Gangning Feng
    Haohui Guo
    Zhirong Chen
    Yaogeng Chen
    Qunhua Jin
    BioMedical Engineering OnLine, 21
  • [33] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Wang, Zheng
    Yang, Yong
    Feng, Gangning
    Guo, Haohui
    Chen, Zhirong
    Chen, Yaogeng
    Jin, Qunhua
    BIOMEDICAL ENGINEERING ONLINE, 2022, 21 (01)
  • [34] A biomechanical comparison of three fixation methods for unstable femoral neck fractures with medial calcar defect
    Koraman, Emre
    Iyetin, Yusuf
    Ozyaman, Oguzhan
    Akyurek, Muhlik
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [35] A biomechanical comparison of three fixation methods for unstable femoral neck fractures with medial calcar defect
    Emre Koraman
    Yusuf Iyetin
    Oguzhan Ozyaman
    Muhlik Akyurek
    Journal of Orthopaedic Surgery and Research, 18
  • [36] Femoral Fractures in Adolescents: A Comparison of Four Methods of Fixation
    Ramseier, Leonhard E.
    Janicki, Joseph A.
    Weir, Shannon
    Narayanan, Unni G.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (05): : 1122 - 1129
  • [37] Treatment of Pauwels type III femoral neck fracture with medial femoral neck support screw: a biomechanical and clinical study
    Gao, Zhichao
    Wang, Mei
    Shen, Baojie
    Chu, Xiaodong
    Ruan, Di
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [38] Novel screw fixation placement configuration for the treatment of Pauwels type III femoral neck fractures: a finite element analysis
    Adamovic, Petra
    Kodvanj, Janos
    Blazevic, Dejan
    Sabalic, Srecko
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2023, 61 (05) : 1005 - 1015
  • [39] Novel screw fixation placement configuration for the treatment of Pauwels type III femoral neck fractures: a finite element analysis
    Petra Adamović
    Janoš Kodvanj
    Dejan Blažević
    Srećko Sabalić
    Medical & Biological Engineering & Computing, 2023, 61 : 1005 - 1015
  • [40] Periprosthetic supracondylar femoral fractures following knee arthroplasty: a biomechanical comparison of four methods of fixation
    Tatu J. Mäkinen
    Herman S. Dhotar
    Simcha G. Fichman
    Matthew J. Gunton
    Mitchell Woodside
    Oleg Safir
    David Backstein
    Thomas L. Willett
    Paul R. T. Kuzyk
    International Orthopaedics, 2015, 39 : 1737 - 1742